Search results for "SENSORS"
showing 10 items of 343 documents
TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance
2018
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scint…
The ATLAS Inner Detector commissioning and calibration
2010
The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and insitu calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energ…
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
2020
Journal of Instrumentation 15(02), P02005 (2020). doi:10.1088/1748-0221/15/02/P02005
MALTA: a CMOS pixel sensor with asynchronous readout for the ATLAS High-Luminosity upgrade
2018
Radiation hard silicon sensors are required for the upgrade of the ATLAS tracking detector for the High- Luminosity Large Hadron Collider (HL-LHC) at CERN. A process modification in a standard 0.18 μm CMOS imaging technology combines small, low-capacitance electrodes (∼2 fF for the sensor) with a fully depleted active sensor volume. This results in a radiation hardness promising to meet the requirements of the ATLAS ITk outer pixel layers (1.5 × 1015 neq /cm2 ), and allows to achieve a high signal-to-noise ratio and fast signal response, as required by the HL-LHC 25 ns bunch crossing structure. The radiation hardness of the charge collection to Non-Ionizing Energy Loss (NIEL) has been previ…
The X-ray Integral Field Unit (X-IFU) for Athena
2014
Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics princi…
Operation of transition-edge sensors with excess thermal noise
2006
The superconducting transition-edge sensor (TES) is currently one of the most attractive choices for ultra-high resolution calorimetry in the keV x-ray band, and is being considered for future ESA and NASA missions. We have performed a study on the noise characteristics of Au/Ti bilayer TESs, at operating temperatures around ~100 mK, with the SQUID readout at 1.5 K. Experimental results indicate that without modifications the back-action noise from the SQUID chip degrades the noise characteristics significantly. We present a simple and effective solution to the problem: by installing an extra shunt resistor which absorbs the excess radiation from the SQUID input, we have reduced the excess …
A $B_4C$-silicon target for the detection of neutrino interactions
1998
This note describes the construction of a target for neutrino interactions composed of passive boron carbide plates interleaved with silicon microstrip detectors. The target contains four layers of passive material with a total mass of 45 kg and 600 single--sided silicon microstrip detectors with a total surface of 1.14 m$^2$ distributed over five layers. It is installed in the NOMAD spectrometer at the CERN SPS neutrino beam. During the 1997 run about 8000 \nm\ charged current interactions were estimated to have occurred in the target. For these events it will be possible to perform a precise measurement of both vertex and kinematical variables. This will provide invaluable experience towa…
Fluctuation-Limited Noise in a Superconducting Transition-Edge Sensor
2003
In order to investigate the origin of the until now unaccounted excess noise and to minimize the uncontrollable phenomena at the transition in x-ray microcalorimeters we have developed superconducting transition-edge sensors into an edgeless geometry, the so-called Corbino disk, with superconducting contacts in the center and at the outer perimeter. The measured rms current noise and its spectral density can be modeled as resistance noise resulting from fluctuations near the equilibrium superconductor-normal metal boundary. Peer reviewed
Integrated optic surface plasmon resonance measurements in a borosilicate glass substrate
2008
The surface plasmon resonance (SPR) technique is a well-known optical method that can be used to measure the refractive index of organic nano-layers adsorbed on a thin metal film. Although there are many configurations for measuring biomolecular interactions, SPR-based techniques play a central role in many current biosensing experiments, since they are the most suited for sensitive and quantitative kinetic measurements. Here we give some results from the analysis and numerical elaboration of SPR data from integrated optics experiments in a particular borosilicate glass, chosen for its composition offering the rather low refractive index of 1.4701 at 633 nm wavelength. These data regard the…
A Study on the Measurement Instrumentation for a Custom-Made Bipendulum Impact Testing Machine
2008
Experimental investigations of structures under impact loads are normally carried out by means of drop-weight testing rigs, which are often tailor made, and require sensors for fast transient measurement of mechanical quantities (namely, force, displacement, velocity, and absorbed energy). Since these tests are quite expensive, time consuming, and, often, not repeatable, the sensors must provide reliable and interpretable results in the first trial. In this paper, a thorough study on the measurement instrumentation suitable to carry out reliable low-velocity impact tests by means of a custom-made bipendulum impact testing machine is presented. Attention has been focused on the choice of the…