Search results for "SENSORS"
showing 10 items of 343 documents
The Use of Accelerometers and Gyroscopes to Estimate Hip and Knee Angles on Gait Analysis
2014
In this paper the performance of a sensor system, which has been developed to estimate hip and knee angles and the beginning of the gait phase, have been investigated. The sensor system consists of accelerometers and gyroscopes. A new algorithm was developed in order to avoid the error accumulation due to the gyroscopes drift and vibrations due to the ground contact at the beginning of the stance phase. The proposed algorithm have been tested and compared to some existing algorithms on over-ground walking trials with a commercial device for assisted gait. The results have shown the good accuracy of the angles estimation, also in high angle rate movement.
A Multi-Position Calibration Method for Consumer-Grade Accelerometers, Gyroscopes, and Magnetometers to Field Conditions
2017
This paper presents a calibration method for consumer-grade accelerometers, gyroscopes, and magnetometers. Considering the calibration of consumer-grade sensors, it is essential that no specialized equipment is required to create reference signals. In addition, the less is required from the reference signals, the more suitable the method is on the field. In the proposed method, the novelty in the calibration of the gyroscopes lies in the exploitation of only the known net rotations between the positions in a multi-position calibration. For accelerometers and magnetometers, the innovation is that the direction of reference signals, the gravity and the magnetic field of the Earth, are estimat…
A Novel Method of Distance Measurement Based on Pulse Position Modulation and Synchronization of Chaotic Signals Using Ultrasonic Radar Systems
2009
This paper deals with a novel method of transmission and receipt of a signal based on both the property of two chaotic systems generating the same chaotic signal when they are synchronized and the property of pulse position modulation (PPM) to be insensitive to the distortions of the transmission channel. The method is discussed in the context of ultrasonic radar systems, in which the transmitter and receiver, which consist of ultrasonic sensors, are near each other, and the received signal consists of the transmitted signal reflected by an obstacle. A reference sinusoidal signal is superimposed to a chaotic signal generated by a master chaotic system, and the whole signal is modulated acco…
Magnetic Tunnel Junction (MTJ) Sensors for Integrated Circuits (IC) Electric Current Measurement
2013
We report on MgO Magnetic Tunnel Junction (MTJ) devices focusing on their potential application in the measurement of electrical current at the integrated circuit level. Single devices and full bridges have been specifically developed for this purpose. A sort of different designs regarding their geometry arrangement as well as the number of constitutive elements have been tested. Experimental characterization has been performed and results including impedance and sensitivity measurements are given.
Design, Building up and First Results of Three Monitored Green Coverings Over a University Department Building
2015
Abstract A viable solution to reducing the buildings’ energy demand is the implementation of green coverings that have been demonstrated to improve the envelope performance, especially in summer season. Anyway, to apply computer models analyzing the energy performance of buildings equipped with such components, the knowledge of specific parameters is needed. Among these, the fractional vegetation coverage and leaf area index are of great importance. By means of an experimental facility, first results of the evaluation of these foliage-related parameters for five types of vegetation are presented.
Label-free wavelength and phase detection based SMS fiber immunosensors optimized with cladding etching
2018
The performance of E-SMS (Etched Singlemode-Multimode-Singlemode) optical fiber structures as immunosensors has been assessed by the implementation of antibody/antigen immunoassays. Through this procedure it has been proven that E-SMS structures are effective and suitable optical platforms for label-free biosensing. Using the phase shift and tracking the wavelength response it was found that the fabricated E-SMS devices exhibited limits of detection (LOD) down up to concentrations of 0.2mg/L of antigens in solution. This was achieved by coating the E-SMS with an antibody-based biolayer (goat IgG) that is able to determine the presence of anti-goat IgG antigen. Both a wavelength detection an…
Towards the fluorogenic detection of peroxide explosives through host-guest chemistry
2018
[EN] Two dansyl-modified beta-cyclodextrin derivatives (1 and 2) have been synthesized as host-guest sensory systems for the direct fluorescent detection of the peroxide explosives diacetone diperoxide (DADP) and triacetone triperoxide (TATP) in aqueous media. The sensing is based on the displacement of the dansyl moiety from the cavity of the cyclodextrin by the peroxide guest resulting in a decrease of the intensity of the fluorescence of the dye. Both systems showed similar fluorescent responses and were more sensitive towards TATP than DADP.
High Sensitivity Refractive Index Sensor Based on Highly Overcoupled Tapered Fiber Optic Couplers
2017
In this paper, a simple and compact fiber-optic sensor based on an overcoupled tapered fiber coupler is studied. The coupler is fabricated to be operated well beyond the initial coupling cycles, where the rapid exchange of energy between outputs ports enable the fabrication of a highly sensitive device. The suitability and sensitivity of the proposed scheme is demonstrated by measuring refractive index (RI) variations of sugar concentrations in water. The device presents a linear response in terms of power transmission or wavelength shift versus RI changes. The best achieved sensitivity is 0.442 units of normalized transmission per unit of sugar concentration, with a noise detection limit o…
Electronic Design for a Bleeding Detector to be Used in Intraoperative Radiotherapy Applications
2021
An electronic design for a bleeding detector used with mobile linac during intraoperative radiotherapy (IORT) is presented. It consists on a readout circuit based on a De Sauty Bridge and a wireless power supply using a supercapacitor. The goal is the measurement of the height of fluid present in the applicator in order to avoid a misadministration dose during the irradiation process. A minimum measurement height of 5 mm is required by clinic to be confident with the selected radiation dose. The measurement circuit uses a capacitive sensor which detects variations lower than 0.1 pF. The readout circuit converts dynamic capacitance variation from the bleeding detector into an analog voltage …
A new fluorescent "turn-on" chemodosimeter for the detection of hydrogen sulfide in water and living cells
2013
[EN] A new fluorescent turn-on probe for the selective detection of hydrogen sulfide in water and living cells based on a 8-hydroxyquinoline fluorophore functionalized with a 2,6-dinitrophenyl ether moiety has been developed.