Search results for "SINGLE-PHOTON"

showing 10 items of 62 documents

Active unilateral condylar hyperplasia : assessment of the usefulness of single photon emission computed tomography

2020

[Background] This study aims to evaluate whether the uptake difference by the condyles evaluated using single photon emission computed tomography (SPECT) examination is useful for predicting the activity of the feature and the advance of this pathology.

Single photon emission computed tomographyCondylar hyperplasiaMandibleSingle-photon emission computed tomographyTemporomandibular jointCondyleMedicineHumansClinical significanceProspective StudiesFacial asymmetryGeneral DentistryTomography Emission-Computed Single-PhotonHyperplasiamedicine.diagnostic_testbusiness.industryResearchMandibular CondyleScintigra-phyCraniometry:CIENCIAS MÉDICAS [UNESCO]ScintigraphyTemporomandibular jointmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASBone maturationSurgeryTomographyOral SurgeryNuclear medicinebusinessFacial symmetry
researchProduct

Metabolic mapping with bioluminescence: basic and clinical relevance

2002

This review is focused on metabolic mapping in biological tissue with quantitative bioluminescence and single photon imaging. Metabolites, such as ATP, glucose and lactate, can be imaged quantitatively and within microscopic dimensions in cryosections from shock frozen biological specimens using enzyme reactions and light emission by luciferases. The technique has been applied in numerous targets and models of experimental biomedical research, such as multicellular spheroids, various organs of laboratory animals in a physiological or pathophysiological state, and even in plant seeds. Among numerous other aspects, data obtained with this method have contributed to the elucidation of mechanis…

Tomography Emission-Computed Single-PhotonPathologymedicine.medical_specialtyCellBioengineeringIn situ hybridizationBiologymedicine.diseaseMalignancyMetastasismedicine.anatomical_structurePredictive Value of TestsNeoplasmsLuminescent MeasurementsImmunologyBiomarkers TumormedicineHumansBioluminescence imagingBioluminescenceImmunohistochemistryLight emissionMolecular BiologyBiotechnologyBiomolecular Engineering
researchProduct

Three-Dimensional Surface Display in Blood Pool Gated SPECT

1994

In 14 patients (4 in good health and 10 with coronary heart disease) a blood pool gated single photon emission computed tomography (SPECT) was executed. The transaxial slices of the cardiac blood pool were reconstructed. A three-dimensional surface display was employed for the analysis of the tomographic data. A fixed distance, a fixed threshold (50%), and some different planes of view were employed. The test permitted visualiza tion of the ventricular and the atrial movements in all patients. The right ventricle was clearly seen in the right anterior oblique plane of view. The aortic beating was seen. In normal patients the left ventricle, clearly seen in left anterior oblique plane, shra…

Tomography Emission-Computed Single-Photonmedicine.diagnostic_testbusiness.industryBlood poolGated SPECTCoronary DiseaseGated Blood-Pool ImagingBlood volume030204 cardiovascular system & hematologySingle-photon emission computed tomographyCoronary heart disease03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureVentricleImage Processing Computer-AssistedHumansMedicineSurface geometry030212 general & internal medicineCardiology and Cardiovascular MedicinebusinessNuclear medicineArteryAngiology
researchProduct

Left-Ventricle Segmentation of SPECT Images of Rats

2015

Single-photon emission computed tomography (SPECT) imaging of the heart is helpful to quantify the left-ventricular ejection fraction and study myocardial perfusion scans. However, these evaluations require a 3-D segmentation of the left-ventricular wall on each phase of the cardiac cycle. This paper presents a fast and interactive graph cut method for 3-D segmentation of the left ventricle (LV) of rats in SPECT images. The method is carried out in three steps. First, 3-D sampling of the LV cavity is made in a spherical-cylindrical coordinate system. Then, a graph-cut-based energy minimization procedure provides delineation of the myocardium centerline surface. From there, it is possible to…

[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingHeart VentriclesBiomedical Engineering030204 cardiovascular system & hematologySingle-photon emission computed tomography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCutmedicineAnimalsComputer visionSegmentationLongitudinal Studies[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingComputingMilieux_MISCELLANEOUSMathematicsTomography Emission-Computed Single-Photonmedicine.diagnostic_testCardiac cycleOrientation (computer vision)business.industryImage segmentationRatsTomographyArtificial intelligencebusinessEmission computed tomography
researchProduct

Bone targeting compounds for radiotherapy and imaging: *Me(III)-DOTA conjugates of bisphosphonic acid, pamidronic acid and zoledronic acid

2016

Background Bisphosphonates have a high adsorption on calcified tissues and are commonly used in the treatment of bone disorder diseases. Conjugates of bisphosphonates with macrocyclic chelators open new possibilities in bone targeted radionuclide imaging and therapy. Subsequent to positron emission tomography (PET) examinations utilizing 68Ga-labelled analogues, endoradiotheraphy with 177Lu-labelled macrocyclic bisphosphonates may have a great potential in the treatment of painful skeletal metastases. Methods Based on the established pharmaceuticals pamidronate and zoledronate two new DOTA-α-OH-bisphosphonates, DOTAPAM and DOTAZOL(MM1.MZ) were successfully synthesized. The ligands were labe…

lcsh:Medical physics. Medical radiology. Nuclear medicineBiodistributionMaterials sciencelcsh:R895-920Hydroxy bisphosphonatesSingle-photon emission computed tomography01 natural sciences030218 nuclear medicine & medical imagingAnalytical Chemistry03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePharmacokineticsmedicineDOTAPharmacology (medical)Radiology Nuclear Medicine and imagingZoledronic acidPharmacologymedicine.diagnostic_test010405 organic chemistrybusiness.industryResearchBone metastaseslcsh:RM1-950Pamidronic acid177LuTheranostics68Ga0104 chemical sciencesZoledronic acidPETlcsh:Therapeutics. PharmacologyDOTAchemistryPositron emission tomographyNuclear medicinebusinessEx vivomedicine.drugEJNMMI Radiopharmacy and Chemistry
researchProduct

Projection and Pinhole-Based Data Acquisition for Small-Animal SPECT Using Storage Phosphor Technology

2007

Three-dimensional Single Photon Emission Computed Tomography (SPECT) can provide high-resolution insight into biomolecular distribution and pharmacokinetics. However, instrument availability and distribution is limited at present,and imaging times can be considerable. To evaluate the large array of novel agents which are becoming available,we find that storage phosphor-based in vivo imaging can provide an important,rapid-throughput transition from the traditional ex vivo sacrifice/gamma counting and autoradiography to full-time course SPECT.

medicine.diagnostic_testPhotostimulated luminescenceComputer sciencebusiness.industryfungifood and beveragesSingle-photon emission computed tomographyData acquisitionSmall animalStorage phosphormedicinePinhole (optics)Projection (set theory)Nuclear medicinebusinessPreclinical imagingBiomedical engineering
researchProduct

D2-receptor imaging with [123I]IBZM and Single Photon Emission Tomography in psychiatry: a survey of current status

1995

D2-dopamine receptors can be visualized in the human brain in vivo by Single Photon Emission Tomography (SPECT) and the radiolabeled benzamide [123I]IBZM. The present paper reviews the current status of this type of functional brain imaging with respect to basic methodological aspects, data analysis and quantification. The results from published clinical studies in different psychiatric patient populations and normal controls with [123I]IBZM are reviewed. [123I]IBZM-SPECT is a powerful tool for the investigation of D2-dopamine receptor status in psychiatric disorders, different types of drug treatment as well as therapeutic and side effects of pharmacologic agents. However, there still is a…

medicine.medical_specialtyReceptor StatusPyrrolidinesNeurologyContrast MediaDrug treatmentDopamine receptor D2Image Processing Computer-AssistedmedicineSingle Photon Emission TomographyHumansPsychiatryBiological PsychiatryBrain ChemistryTomography Emission-Computed Single-Photonmedicine.diagnostic_testReceptors Dopamine D2business.industryBrainHuman brainPsychiatry and Mental healthmedicine.anatomical_structureNeurology123i ibzmPositron emission tomographyBenzamidesDopamine AntagonistsNeurology (clinical)Nuclear medicinebusinessPsychologyJournal of Neural Transmission
researchProduct

Sentinel Node Identification in Melanoma: Current Clinical Impact, New Emerging SPECT Radiotracers and Technological Advancements. An Update of the L…

2020

Background: Melanoma is the most lethal skin cancer with a mortality rate of 262 cases per 100.000 cases. The sentinel lymph node (SLN) is the first lymph node draining the tumor. SLN biopsy is a widely accepted procedure in the clinical setting since it provides important prognostic information, which helps patient management, and avoids the side effects of complete lymph node dissection. The rationale of identifying and removing the SLN relies on the low probability of subsequent metastatic nodes in case of a negative histological exam performed in the SLN. Discussion: Recently, new analytical approaches, based on the evaluation of scintigraphic images are also exploring the possibility …

medicine.medical_specialtySingle Photon Emission Computed Tomography Computed TomographySkin NeoplasmsSentinel lymph nodeSingle-photon emission computed tomographySentinel lymph node biopsyhybrid imagingBiopsymedicineHumansRadiology Nuclear Medicine and imagingsentinel lymph node biopsyMelanomaLymph nodePharmacology99mTc-Tilmanoceptmedicine.diagnostic_testbusiness.industryMelanomaSPECT/CTSentinel nodePrognosismedicine.disease99mTc-colloids; 99mTc-Tilmanocept; Hybrid imaging; Melanoma; Sentinel lymph node biopsy; SPECT/CT; Humans; Lymphoscintigraphy; Melanoma; Prognosis; Radiopharmaceuticals; Sentinel Lymph Node; Single Photon Emission Computed Tomography Computed Tomography; Skin NeoplasmsDissectionHybrid imagingmedicine.anatomical_structure99mTc-colloidsRadiologyRadiopharmaceuticalsSentinel Lymph NodeSkin cancerbusinessLymphoscintigraphyCurrent Radiopharmaceuticals
researchProduct

Comparison of Sulfur Hexafluoride Microbubble (SonoVue)-Enhanced Myocardial Contrast Echocardiography With Gated Single-Photon Emission Computed Tomo…

2013

Objectives The purpose of this study was to compare sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography (MCE) with single-photon emission computed tomography (SPECT) relative to coronary angiography (CA) for assessment of coronary artery disease (CAD). Background Small-scale studies have shown that myocardial perfusion assessed by SonoVue-enhanced MCE is a viable alternative to SPECT for CAD assessment. However, large multicenter studies are lacking. Methods Patients referred for myocardial ischemia testing at 34 centers underwent rest/vasodilator SonoVue-enhanced flash-replenishment MCE, standard Tc-99m-labeled electrocardiography-gated SPECT, and quanti…

medicine.medical_specialtyeducation.field_of_studymedicine.diagnostic_testSonoVuebusiness.industryPopulationischemiaSingle-photon emission computed tomographymedicine.diseasecontrast echocardiographyDipyridamoleCoronary artery diseaseStenosisInternal medicinemedicineStress EchocardiographyCardiologyCardiology and Cardiovascular MedicinebusinesseducationNuclear medicinePerfusionEmission computed tomographymedicine.drugJournal of the American College of Cardiology
researchProduct

Parametric assessment of myocardial perfusion by densitometric evaluation of digital subtraction coronary angiograms: a comparison with tomographic T…

2002

Densitometric results about local myocardial perfusion are compared with those derived from a quantitative analysis of TL-201 single photon emission computer tomograms (TL-201 SPECT). Ten patients underwent conventional TL-201 SPECT at rest and after maximum bicycle stress and dipyridamole infusion the day prior to the investigation. SPECT was applied to provide improved spatial resolution for the detection of perfusion abnormalities. During the catheterization procedure four digital subtraction coronary angiograms were performed, two of the left and two of the right coronary artery both before and after pharmacologically induced hyperemia by intracoronary papaverine. The densitometric para…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrySubtractionSingle-photon emission computed tomographyScintigraphyDipyridamoleCatheterization procedureRight coronary arterymedicine.arteryAngiographymedicineRadiologybusinessNuclear medicinePerfusionmedicine.drug[1990] Proceedings Computers in Cardiology
researchProduct