Search results for "SIZE"
showing 10 items of 2718 documents
Bone and Muscle Development During Puberty in Girls: A Seven-Year Longitudinal Study
2009
The growth of lean mass precedes that of bone mass, suggesting that muscle plays an important role in the growth of bone. However, to date, no study has directly followed the growth of bone and muscle size through puberty and into adulthood. This study aimed to test the hypothesis that the growth of muscle size precedes that of bone size (width and length) and mass during puberty. Bone and muscle properties were measured using pQCT and DXA in 258 healthy girls at baseline (mean age, 11.2 yr) and 1-, 2-, 3-4- and 7-yr follow-up. Growth trends as a function of time relative to menarche were determined from prepuberty to early adulthood for tibial length (TL), total cross-sectional area (tCSA)…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
2012
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study
2018
Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…
The cross-sectional area of the gluteus maximus muscle varies according to habitual exercise loading: Implications for activity-related and evolution…
2015
Greater size of the gluteus maximus muscle in humans compared to non-human primates has been considered an indication of its function in bipedal posture and gait, especially running capabilities. Our aim was to find out how the size of the gluteus maximus muscle varies according to sports while controlling for variation in muscle strength and body weight. Data on gluteus maximus muscle cross-sectional area (MCA) were acquired from magnetic resonance images of the hip region of female athletes (N=91), and physically active controls (N=20). Dynamic muscle force was measured as counter movement jump and isometric knee extension force as leg press. Five exercise loading groups were created: hig…
Targeted Hybrid Nanocarriers as a System Enhancing the Skin Structure
2021
The skin is constantly exposed to external and internal factors that disturb its function. In this work, two nanosystems-levan nanoparticles and a surfactin-stabilized nanoemulsion were preserved (tested for microbial growth) and characterized (size, polydispersity, Zeta potential, and stability). The nanosystems were introduced in the model formulations-cream, tonic, and gel, and confirmed by TEM. The analysis showed that nanoemulsion has a spherical morphology and size 220–300 nm, while levan nanoparticles had irregular shapes independently of the use of matrix and with particle size (130–260 nm). Additionally, we examined the antiradical effect of levan nanoparticles and nanoemulsion in …
Design Issues and Sample Size when Exposure Measurement is Inaccurate
2001
AbstractMeasurement error often leads to biased estimates and incorrect tests in epidemiological studies. These problems can be corrected by design modifications which allow for refined statistical models, or in some situations by adjusted sample sizes to compensate a power reduction. The design options are mainly an additional replication or internal validation study. Sample size calculations for these designs are more complex, since usually there is no unique design solution to obtain a prespecified power. Thus, additionally to a power requirement, an optimal design should also fulfill the criteria of minimizing overall costs. In this review corresponding strategies and formulae are descr…
Aerosol properties of the Eyjafjallajökull ash derived from sun photometer and satellite observations over the Iberian Peninsula
2012
The Eyjafjallajökull ash that crossed over Spain and Portugal on 6e12 May 2010 has been monitored by a set of operational sun photometer sites within AERONET-RIMA and satellite sensors. The sun photometer observations (aerosol optical depth, coarse mode concentrations) and ash products from IASI and SEVIRI satellite sensors, together with FLEXPART simulations of particle transport, allow identifying the volcanic aerosols. The aerosol columnar properties derived from inversions were investigated, indicating specific properties, especially regarding the absorption. The single scattering albedo was high (0.95 at 440 nm) and nearly wavelength independent, although with slight decrease with wave…
Force control and powder dispersibility of spray dried particles for inhalation
2009
This study aims towards a deeper understanding of the correlation between particle morphology, cohesion forces, and aerosol performance of spray dried powders for inhalation. Therefore, forces affecting cohesion and dispersion are consid- ered and some novel contact models are introduced to explain the improved powder dispersibility of corrugated particles. Particles with different degrees of corrugation are prepared by spray drying and characterized. Powder dispersibility is measured by positioning a dry powder inhaler in front of the laser diffraction device. The particle sizes of all powders are in the range of x50 ¼ 2.11 � 0.15 mm. The ratio of mass specific surface area Sm to volume sp…
Effective broadband refractive index retrieval by a white light optical particle counter.
2009
A new approach to retrieve the effective broadband refractive indices (nbroad,eff) of aerosol particles by a white light aerosol spectrometer (WELAS) optical particle counter (OPC) is presented. Using a tandem differential mobility analyzer (DMA)-OPC system, the nbroad,eff are obtained for both laboratory and field applications. This method was tested in the laboratory using substances with a wide range of optical properties. With the obtained nbroad,eff, WELAS aerosol size distributions can be corrected. Therefore, this method can be used for instrument calibration in both laboratory and field measurements. The retrieved effective broadband refractive indices for the scattering aerosols we…
Affective temperaments in tango dancers.
2015
Background: Links between affective temperaments and folk culture have been infrequently explored systematically. Creativity and personality and temperament studies, conversely, have reported several associations. Tango is one of the most typical Argentinean folk dance-musical repertoires. The main purpose of this study is to compare affective temperaments between Argentinean professional tango dancers and the general population. Methods: TEMPS-A was administered to a sample of 63 professional tango dancers and 63 comparison subjects from the general population who did not practice tango. Subscale median scores and total median scores with non-parametric statistics were analyzed. Results: M…