Search results for "SMIS"
showing 10 items of 2316 documents
A model for reactive power tracing by addition of fictitious nodal injections
2012
Abstract This paper proposes an efficient solution to the problem of reactive power flow tracing in electrical transmission networks. For such systems, the tracing techniques used for active power flows cannot be used straightforwardly, due to reactive power variations induced by the line reactances, these variations often being comparable to the powers delivered to the loads. In other words, as is well known, in transmission systems the reactive flows are strongly influenced by the inductive and capacitive effects of the network, making the tracing of power flow and allocation of losses more critical. In this paper, after discussing some methodological aspects, an approach based on the use…
Full-wave FDTD design and analysis of wideband microstrip-to-waveguide transitions
2003
Wideband transitions are designed and analysed by using two different approaches of the finite-difference time-domain (FDTD) method, in combination with the theory of nonuniform transmission lines. These transitions consist of a ridged waveguide-based taper between a shielded microstrip and a standard X-band rectangular waveguide. In the first step, a full-wave 2D-FDTD scheme is used to calculate the dispersion characteristics, as well as the geometry dependence of the impedance in the double ridged waveguide. Once these design curves have been obtained, the stepped transmission line transformer theory is used to design the tapers. In a former step, the nonuniform 3D-FDTD technique is appli…
A Simple Method to Assess Loadability of Radial Distribution Networks
2005
This paper proposes a simple method to asses loadability in radial distribution systems. The relevant problem of voltage stability has been dealt with in past times with reference to higher voltage systems for generation and transmission. In more recent papers, the problem has been considered also at distribution level, since the new electrical energy market requirements and the increasing loadings are now more and more influencing these systems. The proposed method is based on a static approach and proceeds by first evaluating the stability indices and then the different loadability factors (related to real, reactive and apparent power). These calculations are carried out by identifying, s…
A suitable control technique for fault-tolerant converters in Distributed Generation
2011
The penetration of Distributed Generation (DG) in power systems is deeply changing the existing distribution networks which is becoming a very sophisticated and complex systems incorporating both active (generators) and passive systems (distribution systems, converters and loads). The necessary simplification can be obtained dealing with small networks, namely Micro-Grids, reproducing, in a smaller scale, the structure and the problems of large networks including production, transmission and distribution of the electrical energy. In order to achieve an adequate level of reliability, fault-tolerant operations of micro-grids become very important. This result can be achieved only using power …
Ground fault distribution on overhead transmission lines
2006
When a ground fault occurs on an overhead transmission line in a power network with grounded neutral, the fault current returns to the grounded neutral through the tower structures, ground return paths and ground wires. This paper presents an analytical method in order to evaluate the ground fault current distribution in an effectively grounded power network. The effect of soil resistivity, ground resistance of towers and power line configuration, on the magnitude of return currents, has been examined.
A New Solution for Low-Voltage Distributed Generation Interface Protection System
2015
In this paper, a new solution is proposed for the remote monitoring and control of distributed generators (DGs) and energy storage systems (ESSs) connected to low-voltage distribution networks. The proposed system fulfills the in-force standard requirements for the connection of DGs to the utility grid. Moreover, it allows implementing some enhanced functions for the remote control of inverters of DGs and ESSs, not only in terms of disconnection but also in terms of voltage regulation and power shuttering. The proposed solution is based on a new interface protection system and a dedicated secondary substation concentrator, which allows the communication between the distributed system operat…
Electromagnetic immunity analysis of a new interface device with power line communication for smart grid and energy storage applications
2013
An analysis of EMC standards related to smart grid devices with PLC port has been carried out and the standardization lacks have been pointed out with reference to the evaluation of electromagnetic immunity to narrowband, coming from other communication systems connected to the grid, and RF disturbances conducted disturbances, usually present in a power grid. In particular, the paper analyses the electromagnetic conducted immunity of a new interface protection device (ID) for smart grid and energy storage applications. The new ID is equipped with a measuring board, a STM32 microcontroller, for data elaboration and memorization, and a ST7580 N-PSK powerline transceiver. An experimental test …
Facilitating Elements for the Transmission of the Entrepreneurial Spirit in the Classroom
2014
There have been countless tests made to confirm that creativity is a critical skill for entrepreneurs and their entrepreneurial training (Schmidt, J. et al. 2012), even more, practices on divergent thinking increases the entrepreneurial skills of students to generate a greater number and range of ideas, but not, their approaches to solve problems in a creative way. This situation raises a number of questions that should be analyzed before adding creativity and techniques to improve the training of creative thinking to studies (classes), about and in entrepreneurship, as a training channel, improvement or even to the generation of entrepreneurs. Our goal is to show that entrepreneurship is a…
An optimal dimensioning method of a green wall structure for noise pollution reduction
2021
International audience; This paper concern the optimization of a multilayered green wall structure including substrate and foliage in order to reduce as much as possible backward noise reflection and forward transmission from the wall. Each component involved in the wall structure is fully characterized experimentally to get its transfer matrix. Simulation demonstrated that foliage layer superimposed to substrate layer doesn’t affect the transmission losses but contributes greatly to the increase of return losses of the green wall structure. To achieve the best performances in terms of return and forward losses as well as frequency bandwidth, the methods of optimization are discussed inclu…
Ultrastructural Pathology of Anaplastic and Grade II Ependymomas reveals Distinctive Ciliary Structures - Electron Microscopy Redux
2015
Ependymoma tumors likely derive from the ependymal cells lining the CNS ventricular system. In grade II ependymomas, tumor cells resemble typical ependymocytes, while anaplastic ependymomas are poorly differentiated. We studied three grade II and one anaplastic ependymoma, focusing on the ciliary structures. To unambiguously characterize the ultrastructure and number of cilia, we performed electron microscopy serial section analysis of individual cells. Differentiated ependymomas contained large basal bodies and up to three cilia, and lacked centrioles. Anaplastic ependymoma cells showed instead two perpendicularly oriented centrioles and lacked cilia or basal bodies. These findings could c…