Search results for "SOLVENT"
showing 10 items of 1395 documents
Ultrasound-assisted green solvent extraction of high-added value compounds from microalgae Nannochloropsis spp.
2015
Abstract The aim of this work was to investigate ultrasound (US)-assisted green solvent extraction of valuable compounds from the microalgae Nannochloropsis spp. Individual green solvents (water, ethanol (EtOH), dimethyl sulfoxide (DMSO)) and binary mixture of solvents (water-DMSO and water-EtOH) were used for the extraction procedures. Maximum total phenolic compounds yield ( Y p ≈ 0.33) was obtained after US pre-treatment ( W = 400 W, 15 min), being almost 5-folds higher compared to that found for the untreated samples and aqueous extraction ( Y p ≈ 0.06). The highest yield of total chlorophylls ( Y c ≈ 0.043) was obtained after US ( W = 400 W, 7.5 min), being more than 9-folds highe…
Pullulan and dextran: uncommon composition dependent Flory-Huggins interaction parameters of their aqueous solutions.
2008
Vapor pressure measurements were performed for aqueous solutions of pullulan ( M w 280 kg/mol) and dextran ( M w 60 and 2100 kg/mol, respectively) at 25, 37.5, and 50 degrees C. The Flory-Huggins interaction parameters obtained from these measurements, plus information on dilute solutions taken from the literature, show that water is a better solvent for pullulan than for dextran. Furthermore, they evince uncommon composition dependencies, including the concurrent appearance of two extrema, a minimum at moderate polymer concentration and a maximum at high polymer concentration. To model these findings, a previously established approach, subdividing the mixing process into two clearly separa…
Implementation of gradients of organic solvent in micellar liquid chromatography using DryLab®: Separation of basic compounds in urine samples
2014
In micellar liquid chromatography (MLC), chromatographic peaks are more evenly distributed compared to conventional reversed-phase liquid chromatography (RPLC). This is the reason that most procedures are implemented using isocratic elution. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, decreasing the analysis time. Also, it benefits the determination of moderately to low polar compounds in physiological fluids performing direct injection: an initial micellar eluent with a low organic solvent content, or a pure micellar (without surfactant) solution, will provide better protection of the column against the proteins i…
Retention mechanisms for basic drugs in the submicellar and micellar reversed-phase liquid chromatographic modes.
2008
The reversed-phase liquid chromatographic (RPLC) behavior (retention, elution strength, selectivity, efficiency, and peak asymmetry) for a group of basic drugs (beta-blockers), with mobile phases containing the anionic surfactant sodium dodecyl sulfate (SDS) and acetonitrile, revealed different separation environments, depending on the concentrations of both modifiers: hydro-organic, submicellar at low surfactant concentration and high concentration of organic solvent, micellar, and submicellar at high concentration of both surfactant and organic solvent. In the surfactant-mediated modes, the anionic surfactant layer adsorbed on the stationary phase interacts strongly with the positively ch…
An approach to evaluate the information in chromatographic fingerprints: Application to the optimisation of the extraction and conservation condition…
2015
A new approach is reported for high-performance liquid chromatography to measure the level of information in fingerprints. For this purpose, the concept of peak prominence, which is the protruding part of each visible peak with regard to the valleys that delimit it, was used. The peaks in the fingerprints are ranked according to the areas of the peak prominences, and a threshold is established to discriminate between the significant peaks and those that are irreproducible. The approach was applied to evaluate the impact of several extraction conditions (solvent nature and composition, time and temperature of the treatment, amount of sample, and time and temperature of conservation of the ex…
Performance of micellar mobile phases in reversed-phase chromatography for the analysis of pharmaceuticals containing beta-blockers and other antihyp…
1996
A rapid and simple reversed-phase micellar liquid chromatographic procedure for the simultaneous determination of the beta-blockers atenolol, metoprolol and oxprenolol, the diuretics amiloride, bendroflumethiazide, chlorthalidone and hydrochlorothiazide and the vasodilator hydralazine in pharmaceuticals, is proposed. An interpretive optimization procedure, which uses the chromatographic data for only five mobile phases, was applied to select a suitable micellar mobile phase. A comparative study was also made of the performance of micellar and aqueous-organic mobile phases in the analysis of pharmaceuticals that combine beta-blockers and diuretics. The determination of all the drugs could be…
Effect of tetrahydrofuran on the conductance and ion-pairing of hydrogen chloride in wet and dry methanol mixtures
1995
The molar conductance of dilute solutions of HCl in wet (68.5% methanol + 31.5% tetrahydrofurane mixtures at 25°C have been measured. The data were analyzed using the Fuoss-Hsia equation to calculate the infinite dilution molar conductances and association constants. The trend of the limiting conductances in these mixtures as a function of the water content shows, once more, the peculiar minimum due to the anomalous proton conductance mechanism. From these data the limiting molar conductance in the anhydrous binary solvent system was evaluated. The percentage excess proton mobility with respect to potassium ion has also been determined. All these data are compared to those found in a binary…
Simple high-performance liquid chromatographic assay for polyamines and their monoacetyl derivatives.
1993
A rapid reversed-phase high-performance liquid chromatographic method, using pre-column derivatization with benzoyl chloride and ultraviolet detection at 254 nm, was developed for the simultaneous measurement of polyamines and their monoacetyl derivatives. Calibration curves were linear for concentrations from 1.25 to 25 nmol/ml. The method was employed to assay these compounds in chick embryo retina explants using organic solvent extraction and 1,7-diaminoheptane as an internal standard. This simple and sensitive method can be applied to routine determinations of these compounds in various biological samples.
Synthesis and properties of chemically modified dihydroxy-, hydroxyamino- and amino-functional silica packings in adsorption chromatography
1980
1,2-Dihydroxy-3-propoxypropyl (HPP), 1-amino-2-hydroxy-3-propoxypropyl (AHP) and 3-(2-aminoethylamino)propyl (AEAP) silica packings were synthesized by means of both a surface modification and a bulk modification procedure. In surface modification a complete monolayer of bonded groups could be achieved. The modifiers reacted with the silanol groups according to a bifunctional mechanism. Eluotropic series of solvents were established on these polar modified silicas referring to n-heptane having ɛ∘=0. The solvent parameter ratio of modified to bare silica was found to be constant over a wide range of solvent compositions as \(\varepsilon _{{\text{HPP - silica}}}^ \circ = 0.26\varepsilon _{{\t…
Solvent selection in liquid chromatography
2017
Many solvents and additives are used to prepare mobile phases in liquid chromatography (LC). Also, mixtures of solvents at different ratios are used to modify the mobile-phase properties. This can make solvent selection for method development a puzzling task, unless suitable guidelines are followed. This chapter summarizes the most common strategies used by skilled chromatographers in reversed-phase, normal-phase, and hydrophilic interaction LC. These are based on considerations about the global polarity of solutes, stationary phase, and mobile phase, which determine the elution strength, and on the particular profile of the contributions of intermolecular interactions to the global polarit…