Search results for "SPECTROSCOPY"
showing 10 items of 10293 documents
Determination of Cd, Cu, Pb and Zn content of infant formulas by differential pulse anodic stripping voltammetry (DPASV).
1994
The differential pulse anodic stripping voltammetry (DPASV) method described is based on the one reported by Hasse et al., but adapted to normal laboratory conditions. The values obtained in the estimation of the analytical parameters (linearity, detection and quantification limits, precision and accuracy) show that in the conditions described the method is sensitive enough, reliable and useful for determining these elements in infant formulas. A comparison between DPASV and atomic absorption spectroscopy (AAS) methods in the conditions described here shows that the former is less sensitive but that they are similar in precision. The cadmium, copper, lead and zinc contents of different type…
Information content of data and variables and types of weighting in least-squares regression methods
1990
Abstract Algorithms are given for evaluating the relative amount of useful information related to a particular parameter which is carried by individual data points and intervals of the variables. The algorithms provide an efficient means of using the information contained in a set of data. Applications to the optimization of weighting in regression methods are described. Several informational and combined informational-statistical types of weighting are studied as a means of improving the accuracy and precision of the parameters obtained by non-linear regression.
Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…
2012
The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…
Fluorimetric determination of amphetamine in urine by flow injection with on-line liquid–liquid extraction
2001
Abstract Determination of amphetamine in urine was performed by batch and flow injection methodologies. The suitable experimental conditions for fluorimetric measurements were established. The liquid–liquid extraction was carried out at pH 13 using diethyl ether as extracting reagent. The measurement conditions were 260 nm and 277 nm for excitation and emission wavelengths, respectively. The method requires standard addition calibration and Youden blank correction. The influence of the main metabolites of amphetamine and metamphetamine were studied. The accuracy and precision of the proposed method was tested and the method is adapted to the flow injection procedure with on-line extraction.
Determination of phosphorus by instrumental neutron activation and bremsstrahlung measurement in bone samples
1997
A non destructive method based on the31P(n,γ)32P reaction for the assay of phosphorus in bone samples is described. This method involves a thermal neutron irradiation of 2 minutes in a reactor followed by the measurement of the bremsstrahlung produced by the β− of32P in a Ge-detector surrounded by an anti-Compton shield. Accuracy and precision were tested by analysing the certified NIST 1486 Bone Meal reference material and tri-calcium phosphate (Ca3(PO4)2) samples. The value obtained for the reference material was in good agreement with the certified value and with relative standard deviation of 4.1% the precision was acceptable. The value obtained for Ca3(PO4)2 shows a deviation of −6% fr…
Gaia -ESO Survey: Analysis of pre-main sequence stellar spectra
2015
This paper describes the analysis of UVES and GIRAFFE spectra acquired by the Gaia-ESO Public Spectroscopic Survey in the fields of young clusters whose population includes pre-main sequence (PMS) stars. Both methods that have been extensively used in the past and new ones developed in the contest of the Gaia-ESO survey enterprise are available and used. The internal precision of these quantities is estimated by inter-comparing the results obtained by such different methods, while the accuracy is estimated by comparison with independent external data, like effective temperature and surface gravity derived from angular diameter measurements, on a sample of benchmarks stars. Specific strategi…
A comparative study of the performance of acetonitrile and methanol in the multi-linear gradient separation of proteic primary amino acids
2006
The performance of the separation of proteic primary amino acids using multi-linear gradients of acetonitrile and methanol was studied under an experimental-design basis, using an Inertsil ODS-3 column and pre-column derivatization with o-phthaldialdehyde (OPA) and N-acetyl-l-cysteine (NAC). Elution strength, peak properties, resolution, and analysis time, were examined. The optimal separation was established through modeling, using information obtained from isocratic data. By optimizing the separation with gradients of increasing complexity, acceptable resolution was possible, being glycine/threonine the critical pair. Multi-criteria decision-making (Derringer desirabilities) was applied t…
Characterization of particle morphology of biochanin A molecularly imprinted polymers and their properties as a potential sorbent for solid-phase ext…
2014
Abstract Molecularly imprinted polymers (MIPs) with biochanin A as a template were obtained using a bulk polymerization with non-covalent imprinting approach. The polymers were prepared in acetonitrile as porogen, using ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The synthesis, with an application of 1′,1′-azobis(cyclohexanecarbonitrile) (ACHN) as an initiator, has been performed thermally. During the synthesis process the effect of different functional monomers such as methacrylic acid (MAA), acrylamide (AA) and 4-vinylpyridine (4-VP) was investigated. The application of nitrogen sorption porosimetry, scanning electron microscopy (SEM), and Fourier transform infrared spec…
Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.
2003
The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…
Zur protonenkatalysierten Aralkylierung von 1,2,3-Trimethylindol und 1,2,3,4-Tetrahydrocarbazol mit Arylaldehyden
1987
1,2,3-Trimethylindol (2) liefert mit Benzaldehyden die Kondensationsprodukte 5 und 6, wahrend aus den NH-Indolen 1 und 3 die Verbindungen 7 und 8 entstehen. Proton-catalyzed Aralkylation of 1,2,3-Trimethylindole and 1,2,3,4-Tetrahydrocarbazole with Arylaldehydes Reaction of 1,2,3-trimethylindole (2) with benzaldehydes leads to the condensation compounds 5 and 6, the NH-indoles 1 and 3, however, give 7 and 8.