Search results for "STED"

showing 10 items of 2256 documents

A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS

2000

The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically al…

Physicsbusiness.industryAirRadiotherapy Planning Computer-AssistedAttenuationmedicine.medical_treatmentMonte Carlo methodBrachytherapyIsotropyWaterGeneral MedicineSievert integralComputational physicsCesium RadioisotopesLookup tablemedicineHumansDosimetryRadiometryAnisotropyNuclear medicinebusinessMonte Carlo MethodMedical Physics
researchProduct

Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources

2002

The low dose rate CDC-type miniature cylindrical 137 Cs sources are available, with one or three active beads, for use in source trains in automatic and manual afterloading systems for gynecological brachytherapy. Absolute dose rate distributions in water have been calculated around these sources using the Monte CarloGEANT3 code and they are presented as conventional two-dimensional Cartesian lookup tables. The AAPM Task Group 43 formalism for dose calculation has been also applied. The dose rate constant obtained for the one bead source is Λ=1.113±0.003 cGyh −1 U −1 , and the value for the three bead source is Λ=1.103±0.003 cGyh −1 U −1 . Finally, for the treatment planning systems based o…

Physicsbusiness.industryAirRadiotherapy Planning Computer-Assistedmedicine.medical_treatmentAttenuationBrachytherapyMonte Carlo methodBrachytherapyGeneral MedicineComputational physicslaw.inventionlawLookup tablemedicineDosimetryCartesian coordinate systemRadiometryRadiation treatment planningDose rateNuclear medicinebusinessMonte Carlo MethodAlgorithmsMedical Physics
researchProduct

Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…

2004

The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…

Physicsbusiness.industryPoint sourcemedicine.medical_treatmentAttenuationRadiotherapy Planning Computer-AssistedPhysics::Medical PhysicsMonte Carlo methodBrachytherapyBrachytherapyGeneral MedicineComputational physicsSelectron tubeSuperposition principleCesium RadioisotopesmedicineDosimetryPolar coordinate systemNuclear medicinebusinessRadiometryMonte Carlo MethodSoftwareMedical physics
researchProduct

Time-Independent Canonical Perturbation Theory

2001

First we consider the perturbation calculation only to first order, limiting ourselves to only one degree of freedom. Furthermore, the system is to be conservative, ∂ H∕∂ t = 0, and periodic in both the unperturbed and perturbed case. In addition to periodicity, we shall require the Hamilton–Jacobi equation to be separable for the unperturbed situation. The unperturbed problem H0(J0) which is described by the action-angle variables J0 and w0 will be assumed to be solved. Thus we have, for the unperturbed frequency: $$\displaystyle{ \nu _{0} = \frac{\partial H_{0}} {\partial J_{0}} }$$ (10.1) and $$\displaystyle{ w_{0} =\nu _{0}t +\beta _{0}\;. }$$ (10.2) Then the new Hamiltonian reads, up t…

Physicssymbols.namesakeMøller–Plesset perturbation theorysymbolsCanonical coordinatesCanonical transformationAction-angle coordinatesHamiltonian (quantum mechanics)First orderPoincaré–Lindstedt methodMathematical physicsSeparable space
researchProduct

Photoplethysmography in dogs and cats: a selection of alternative measurement sites for a pet monitor.

2018

Objective Photoplethysmography (PPG) is an increasingly popular health and well-being tool for monitoring heart rate and oxygen saturation. Due to the pigmentation and hairiness of dogs and cats, a pulse oximeter is routinely placed solely on the tongue. As this approach is feasible only for pet monitor use during surgical procedures, we investigate PPG signal quality on several other measurement sites that would be better tolerated by conscious animals. Approach Acquired PPG signals are analyzed by four signal quality indices: mean baseline, signal power, kurtosis, and tolerance score. Main results In dogs, the metacarpus and tail can be substituted for oral pulse oximeter placement since …

Physiology0206 medical engineeringBiomedical EngineeringBiophysics02 engineering and technologySignal03 medical and health sciences0302 clinical medicineDogsSignal qualityPhysiology (medical)PhotoplethysmogramHeart rateMedicineAnimalsPhotoplethysmographyOxygen saturation (medicine)CATSPulse (signal processing)business.industrySignal Processing Computer-AssistedPetsSurgical procedures020601 biomedical engineeringCatssense organsbusiness030217 neurology & neurosurgeryBiomedical engineeringPhysiological measurement
researchProduct

Interictal cardiorespiratory variability in temporal lobe and absence epilepsy in childhood

2015

It is well known that epilepsy has a profound effect on the autonomic nervous system, especially on the autonomic control of heart rate and respiration. This effect has been widely studied during seizure activity, but less attention has been given to interictal (i.e. seizure-free) activity. The studies that have been done on this topic, showed that heart rate and respiration can be affected individually, even without the occurrence of seizures. In this work, the interactions between these two individual physiological variables are analysed during interictal activity in temporal lobe and absence epilepsy in childhood. These interactions are assessed by decomposing the predictive information …

PhysiologyInformation Theory02 engineering and technologyElectroencephalographyMultimodal Imaging01 natural sciencesAutonomic controlElectrocardiographyEpilepsy0302 clinical medicineHeart RateHeart rate variabilityChildmedicine.diagnostic_testSISTARespirationheart rate variabilityElectroencephalographySignal Processing Computer-Assistedtemporal lobe epilepsy3. Good healthabsence epilepsyCardiologyPsychologymedicine.medical_specialty0206 medical engineeringBiophysicsBiomedical EngineeringTemporal lobe03 medical and health sciencesInternal medicinePhysiology (medical)0103 physical sciencesRespirationHeart ratemedicineHumansIctal010306 general physicsinformation dynamicbusiness.industryCardiorespiratory fitnessmedicine.disease020601 biomedical engineeringAutonomic nervous systemEpilepsy AbsenceEpilepsy Temporal LobeBiophysicSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaepilepsyTransfer entropybusinessNeuroscience030217 neurology & neurosurgery
researchProduct

ATP distribution and localization of mitochondria in Suberites domuncula (Olivi 1792) tissue

2011

SUMMARY The metabolic energy state of sponge tissue in vivo is largely unknown. Quantitative bioluminescence-based imaging was used to analyze the ATP distribution of Suberites domuncula (Olivi 1792) tissue, in relation to differences between the cortex and the medulla. This method provides a quantitative picture of the ATP distribution closely reflecting the in vivo situation. The obtained data suggest that the highest ATP content occurs around channels in the sponge medulla. HPLC reverse-phase C-18, used for measurement of ATP content, established a value of 1.62 μmol ATP g–1 dry mass in sponge medulla, as opposed to 0.04 μmol ATP g–1 dry mass in the cortex, thus indicating a specific and…

PhysiologyProtein subunitIn situ hybridizationAquatic ScienceBiologyMitochondrionAdenosine TriphosphateImage Processing Computer-AssistedAnimalsMolecular BiologyChromatography High Pressure LiquidIn Situ HybridizationEcology Evolution Behavior and SystematicsMedullaArginine KinaseArginine kinaseATP distribution; mitochondria; imaging bioluminescence; HPLC; Porifera; Suberites domunculabiology.organism_classificationImmunohistochemistryMitochondriaSuberites domunculaSpongeBiochemistryOrgan SpecificityInsect Sciencebiology.proteinAnimal Science and ZoologyMitochondrion localizationEnergy MetabolismSuberitesJournal of Experimental Biology
researchProduct

Multistage recovery process of seaweed pigments: Investigation of ultrasound assisted extraction and ultra-filtration performances

2017

International audience; The objectives of this study were first to evaluate the performance of seaweed pigments’ recovery through ultrasound assisted extraction (UAE) and ultra-filtration (UF), and second to investigate the membrane fouling mechanism and evidence the threshold flux during filtration. The pigments’ recovery from the extract was performed using 5 kDa and 10 kDa ultra-filtration membranes. Results showed that increasing the extraction temperature in the range of 40–60 °C was proportional to chlorophyll extraction efficiency, while the maximal carotenoid yield was achieved at 50 °C. Ultrasonic power (from 100 W to 300 W) facilitated the extraction of both chlorophylls and carot…

PigmentsMembrane fouling[SDV.BIO]Life Sciences [q-bio]/BiotechnologyGeneral Chemical Engineering[SDV]Life Sciences [q-bio]Biochemistrylaw.inventionchemistry.chemical_compound0404 agricultural biotechnologylawUltra-filtration[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process EngineeringCarotenoidFiltrationchemistry.chemical_classificationChromatographyFoulingMembrane foulingExtraction (chemistry)Threshold flux04 agricultural and veterinary sciencesPermeationSeaweed040401 food scienceMembranechemistryChlorophyllUltrasound-assisted extraction[SDV.AEN]Life Sciences [q-bio]/Food and NutritionFood ScienceBiotechnology
researchProduct

Unsupervised recognition of retinal vascular junction points.

2014

Landmark points in retinal images can be used to create a graph representation to understand and to diagnose not only different pathologies of the eye, but also a variety of more general diseases. Aim of this paper is the description of a non-supervised methodology to distinguish between bifurcations and crossings of the retinal vessels, which can be used in differentiating between arteries and veins. A thinned representation of the binarized image, is used to identify pixels with three or more neighbors. Junction points are classified into bifurcations or crossovers according to their geometrical and topological properties. The proposed approach is successfully compared with the state-of-t…

PixelSettore INF/01 - InformaticaComputer sciencebusiness.industryRetinal VesselsRetinalSensitivity and SpecificityImage (mathematics)Pattern Recognition Automatedchemistry.chemical_compoundUnsupervised Recognition of Retinal Vascular Junction PointschemistryImage Interpretation Computer-AssistedHumansComputer visionArtificial intelligenceRepresentation (mathematics)businessAlgorithmsAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
researchProduct

Influence of pixel size on quantification of airway wall thickness in computed tomography.

2009

Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …

Pixelmedicine.diagnostic_testbusiness.industryPhantoms ImagingComputed tomographyField of viewBronchiBronchographycomputer.software_genreImaging phantomRadiographic Image EnhancementFull width at half maximumVoxelApproximation errorComputer GraphicsMedicineHumansRadiographic Image Interpretation Computer-AssistedRadiology Nuclear Medicine and imagingbusinessNuclear medicineTomography X-Ray ComputedImage resolutioncomputerSoftwareJournal of computer assisted tomography
researchProduct