Search results for "STRAHLUNG"
showing 10 items of 117 documents
Microwave emission related to cyclotron instabilities in a minimum-Belectron cyclotron resonance ion source plasma
2015
Electron cyclotron resonance ion sources (ECRIS) have been essential in the research and applications of nuclear physics over the past 40 years. They are extensively used in a wide range of large-scale accelerator facilities for the production of highly charged heavy ion beams of stable and radioactive elements. ECRISs are susceptible to kinetic instabilities due to resonance heating mechanism leading to anisotropic electron velocity distribution function. Instabilities of cyclotron type are a proven cause of frequently observed periodic bursts of 'hot' electrons and bremsstrahlung, accompanied with emission of microwave radiation and followed by considerable drop of multiply charged ions c…
Bremsstrahlung from a repulsive potential: attosecond pulse generation
2008
The collision of an electron against a repulsive potential in the presence of a laser field is investigated. It is found that a sufficiently strong laser field forces the electron to remain in the neighbourhood of the repulsive potential causing bremsstrahlung. By appropriately filtering the emitted signal, an electron in the presence of a repulsive potential is capable of generating attosecond pulses.
Studies of plasma breakdown and electron heating on a 14 GHz ECR ion source through measurement of plasma bremsstrahlung
2011
Temporal evolution of plasma bremsstrahlung emitted by a 14?GHz electron cyclotron resonance ion source (ECRIS) operated in pulsed mode is presented in the energy range 1.5?400?keV with 100??s resolution. Such a high temporal resolution together with this energy range has never been measured before with an ECRIS. Data are presented as a function of microwave power, neutral gas pressure, magnetic field configuration and seed electron density. The saturation time of the bremsstrahlung count rate is almost independent of the photon energy up to 100?keV and exhibits similar characteristics with the neutral gas balance. The average photon energy during the plasma breakdown is significantly highe…
Soft-dielectron excess in proton-proton collisions at $\sqrt{s}$ = 13 TeV
2021
Physical review letters 127(4), 042302 (2021). doi:10.1103/PhysRevLett.127.042302
Unveiling pure-metal ejecta X-ray emission in supernova remnants through their radiative recombination continuum
2020
Spectral analysis of X-ray emission from ejecta in supernova remnants (SNRs) is hampered by the low spectral resolution of CCD cameras, which creates a degeneracy between the best-fit values of abundances and emission measure. The combined contribution of shocked ambient medium and ejecta to the X-ray emission complicates the determination of the ejecta mass and chemical composition, leading to big uncertainties in mass estimates and it can introduce a bias in the comparison between the observed ejecta composition and the yields predicted by explosive nucleosynthesis. We explore the capabilities of present and future spectral instruments with the aim of identifying a spectral feature which …
The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS.
2010
Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount o…
Study of encapsulated T170m sources for their potential use in brachytherapy
2010
Purpose: High dose-rate (HDR) brachytherapy is currently performed with {sup 192}Ir sources, and {sup 60}Co has returned recently into clinical use as a source for this kind of cancer treatment. Both radionuclides have mean photon energies high enough to require specific shielded treatment rooms. In recent years, {sup 169}Yb has been explored as an alternative for HDR-brachytherapy implants. Although it has mean photon energy lower than {sup 192}Ir, it still requires extensive shielding to deliver treatment. An alternative radionuclide for brachytherapy is {sup 170}Tm (Z=69) because it has three physical properties adequate for clinical practice: (a) 128.6 day half-life, (b) high specific a…
Synchrotron radiation studies on luminescence of Eu2+-doped LaCl3 microcrystals embedded in a NaCl matrix
2012
Abstract LaCl3:Eu2+ microcrystals dispersed in the NaCl matrix have been obtained in the NaCl–LaCl3(1 mol.%)–EuCl3(0.1 mol.%) crystalline system. The low-temperature luminescent properties of these microcrystals have been studied upon the VUV and UV excitation by the synchrotron radiation. The spectroscopic parameters as well as decay time constants of Eu2+-doped LaCl3 host have been established. The excitation mechanism of divalent europium centers through energy transfer and reabsorption is discussed.
Measurement of the radiative K-e3 branching ratio
2005
We present a measurement of the relative branching ratio of the decay KL -> pi e nu gamma (Ke3gamma) with respect to KL-> pi e nu (gamma) (Ke3+Ke3gamma) decay. The result is based on observation of 19 000 Ke3gamma and 5.6 x 10^6 Ke3 decays. The value of the branching ratio is Br(Ke3gamma, Egamma^*>30 MeV,theta(e,gamma)^*>20^o)/Br(Ke3)= (0.964+-0.008+0.011-0.009)%. This result agrees with theoretical predictions but is at variance with a recently published result.
A collision timing monitor for SuperKEKB
2017
Abstract The analysis of beamstrahlung radiation, emitted from a beam of charged particles due to the electromagnetic interaction with a second beam of charged particles, provides a diagnostic tool that can be used to monitor beam–beam collisions in a e + e − storage ring. In this paper we show that the beamstrahlung time profile is related to the timing of the collisions and the length of the beams, and how its measurement can be used to monitor and optimize collisions at the interaction point of the SuperKEKB collider. The method has a unique passive monitor capability, since it allows to monitor the timing of the collision without disturbing (scanning) the beam–beam timing, which needs t…