Search results for "Sample collection"

showing 10 items of 37 documents

Circulating miR-200–family micro-RNAs have altered plasma levels in patients with endometriosis and vary with blood collection time

2015

Objective To determine whether circulating micro-RNA (miR) 200a, miR-200b, and miR-141 have altered levels in patients with endometriosis compared with control individuals. Design Experimental laboratory study. Setting University. Patient(s) Patients with endometriosis (n = 61), laparoscopically confirmed endometriosis-free women (n = 35), and self-reported healthy women (n = 30) were included in the study. Intervention(s) None. Main Outcome Measure(s) Plasma miRNA levels in endometriosis patients and control subjects. Result(s) We found that the levels of studied miRNAs varied with blood collection time, being lower in the morning than in the evening. When blood collection time was taken i…

Adultmedicine.medical_specialtyTime FactorsEveningEndometriosisEndometriosisDiseaseReal-Time Polymerase Chain ReactionGastroenterologyYoung Adult03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansStage (cooking)030304 developmental biologyMorningGynecologyBlood Specimen Collection0303 health sciences030219 obstetrics & reproductive medicinebusiness.industryGene Expression ProfilingObstetrics and GynecologyMiddle Agedmedicine.disease3. Good healthMicroRNAsGene Expression RegulationReproductive MedicineCase-Control StudiesMultigene FamilyBiomarker (medicine)FemaleSample collectionbusinessBiomarkersBlood samplingFertility and Sterility
researchProduct

Current air quality analytics and monitoring: a review.

2014

This review summarizes the different tools and concepts that are commonly applied in air quality monitoring. The monitoring of atmosphere is extremely important as the air quality is an important problem for large communities. Main requirements for analytical devices used for monitoring include a long period of autonomic operation and portability. These instruments, however, are often characterized by poor analytical performance. Monitoring networks are the most common tools used for monitoring, so large-scale monitoring programmes are summarized here. Biomonitoring, as a cheap and convenient alternative to traditional sample collection, is becoming more and more popular, although its main …

Air PollutantsAtmosphere (unit)Chromatography GasChemistrybusiness.industryElectrochemical TechniquesPlantsBiochemistryAnalytical ChemistryAir quality monitoringSoftware portabilityRisk analysis (engineering)AnalyticsEnvironmental chemistryLab-On-A-Chip DevicesRemote Sensing TechnologyPlant BarkEnvironmental ChemistrySample collectionbusinessAir quality indexSpectroscopyEnvironmental qualityDrawbackEnvironmental MonitoringAnalytica chimica acta
researchProduct

Molecularly imprinted polymer-based device for field collection of oral fluid samples for cocaine identification.

2020

In this paper, a low-cost, rapid, easy, and potentially portable tool for the identification of cocaine and its semi-quantitative determination in oral fluid has been proposed. A field collection device has been designed, based on a cotton pad with an indicator and a molecularly imprinted polymer (MIP) sorbent, to selective retain cocaine from oral fluid components. After sample collection, cocaine is transferred by using phosphate buffer to the MIP and then eluted with 2-propanol. The obtained extract is analysed by ion mobility spectrometry (IMS), providing a cut-off value of 20 µg L-1 that identifies 100 % true-positive and 95 % true-negative samples. The MIP-IMS procedure has been valid…

ChromatographyElutionIon-mobility spectrometryChemistryPolymers010401 analytical chemistryOrganic ChemistryMolecularly imprinted polymerGeneral Medicine010402 general chemistry01 natural sciencesBiochemistry0104 chemical sciencesAnalytical ChemistryMolecular ImprintingSubstance Abuse DetectionHealth personnelIdentification (information)CocaineIon Mobility SpectrometryOral fluidHumansSample collectionSalivaLateral flow immunoassayJournal of chromatography. A
researchProduct

Grapevine and wine metabolomics-based guidelines for fair data and metadata management

2021

In the era of big and omics data, good organization, management, and description of experimental data are crucial for achieving high-quality datasets. This, in turn, is essential for the export of robust results, to publish reliable papers, make data more easily available, and unlock the huge potential of data reuse. Lately, more and more journals now require authors to share data and metadata according to the FAIR (Findable, Accessible, Interoperable, Reusable) principles. This work aims to provide a step-by-step guideline for the FAIR data and metadata management specific to grapevine and wine science. In detail, the guidelines include recommendations for the organization of data and meta…

Computer scienceEndocrinology Diabetes and MetabolismInteroperabilityMicrobiologyBiochemistryAnnotationMetadata managementTechnical NoteVitisSettore CHIM/10 - CHIMICA DEGLI ALIMENTIwineMolecular BiologyPublicationmetabolites<i>Vitis</i>mass spectrometrybusiness.industryplantsExperimental dataData scienceopen-data; plants; omics; Vitis; wine; metabolites; chromatography; mass spectrometryQR1-502Chromatography; Mass spectrometry; Metabolites; Omics; Open-data; Plants; Vitis; WineomicsMetadataOpen dataopen-datachromatographySample collectionbusiness
researchProduct

Miniaturized solid-phase extraction techniques

2015

More than 80% of analysis time is spent on sample collection and sample preparation, so sample preparation is a critical part of the analytical process. Traditionally, liquid-liquid extraction was developed and employed to screen for general unknowns. However, solid-phase extraction (SPE) is becoming highly popular as an alternative, due to its simplicity and economy in terms of time and solvent. This review summarizes the current state of the art and the future prospects for green analytical chemistry with special emphasis on environment-friendly sample-preparation techniques based on the solid phase. We discuss in detail miniaturized SPE techniques, based on the most relevant, most repres…

Computer sciencebusiness.industryExtraction (chemistry)Analytical chemistrySample preparationSolid phase extractionSample collectionSolid-phase microextractionProcess engineeringbusinessSpectroscopyAnalytical ChemistryTrAC Trends in Analytical Chemistry
researchProduct

Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

2013

Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including prac…

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryGeneral MedicineSolid-phase microextractionBiochemistryAnalytical ChemistryMeasuring instrumentSample preparationSample collectionSolid phase extractionSolid Phase MicroextractionJournal of chromatography. A
researchProduct

Norm values for eosinophil cationic protein in nasal secretions: influence of specimen collection

1999

Background Eosinophil granulocytes play an important role in allergic inflammation of the nasal mucosa. Eosinophil cationic protein (ECP) is a specific eosinophil granule protein released upon activation of these cells. ECP concentration in nasal secretions has been demonstrated to be a good marker for the activity of eosinophilic nasal mucosal inflammation. The clinical use of such a marker requires defined values which are regarded as pathological or within normal range. In analyses of nasal secretion samples, the sampling method has an important influence on the data obtained. Objective We investigated ECP levels in nasal secretions (NS) of healthy volunteers obtained by seven different …

Eosinophil cationic proteinbusiness.industrymedicine.medical_treatmentImmunologyMucous membrane of noserespiratory systemEosinophilmedicine.anatomical_structureSpecimen collectionNasal sprayImmunologyotorhinolaryngologic diseasesmedicineImmunology and AllergyNasal LavageSample collectionbusinessNoseClinical &amp; Experimental Allergy
researchProduct

Helminth Microbiota Profiling Using Bacterial 16S rRNA Gene Amplicon Sequencing: From Sampling to Sequence Data Mining

2021

Symbiont microbial communities play important roles in animal biology and are thus considered integral components of metazoan organisms, including parasitic worms (helminths). Nevertheless, the study of helminth microbiomes has thus far been largely overlooked, and symbiotic relationships between helminths and their microbiomes have been only investigated in selected parasitic worms. Over the past decade, advances in next-generation sequencing technologies, coupled with their increased affordability, have spurred investigations of helminth-associated microbial communities aiming at enhancing current understanding of their fundamental biology and physiology, as well as of host-microbe intera…

FOS: Computer and information sciencesBioinformaticsComputational biologyBiologyDNA sequencingSymbiosisHelminthsRNA Ribosomal 16Sparasitic diseasesHelminthAnimalsData MiningHelminthsMicrobiomeGeneBacterial 16S rRNA geneIndirect life cycleHigh-throughput sequencingMicrobiotaHigh-Throughput Nucleotide SequencingGenes rRNASchistosoma mansoniAmplicon sequencingHuman genomeSample collectionWorm-associated microbiome
researchProduct

A Multicentre Pilot Study of a Two-Tier Newborn Sickle Cell Disease Screening Procedure with a First Tier Based on a Fully Automated MALDI-TOF MS Pla…

2019

The reference methods used for sickle cell disease (SCD) screening usually include two analytical steps: a first tier for differentiating haemoglobin S (HbS) heterozygotes, HbS homozygotes and β-thalassemia from other samples, and a confirmatory second tier. Here, we evaluated a first-tier approach based on a fully automated matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) platform with automated sample processing, a laboratory information management system and NeoSickle® software for automatic data interpretation. A total of 6701 samples (with high proportions of phenotypes homozygous (FS) or heterozygous (FAS) for the inherited genes for sickle h…

MALDI-TOFPediatricsmedicine.medical_specialtythalassemia[SDV]Life Sciences [q-bio]Sample (statistics)01 natural sciencesArticle03 medical and health sciencesImmunology and Microbiology (miscellaneous)preventionmedicineDisease Screening Procedure030304 developmental biologymass spectrometry0303 health sciencesNewborn screeningbusiness.industryMALDI-TOF; sickle cell disease; newborn screening; mass spectrometry; thalassemia; preventionnewborn screening010401 analytical chemistrylcsh:RJ1-570Obstetrics and GynecologyData interpretationlcsh:Pediatrics0104 chemical sciencesMatrix-assisted laser desorption/ionizationFully automatedSickle haemoglobinPediatrics Perinatology and Child Healthsickle cell diseaseSample collectionbusinessInternational Journal of Neonatal Screening
researchProduct

Rat liver preservation by hypothermic oscillating liver perfusion compared to simple cold storage.

1998

Rat livers were preserved hypothermically for 10 or 24 h in vitro as if for transplantation. Two methods of preservation were compared using physiological and biochemical parameters: simple storage and oscillating perfusion. By measuring the nucleotides after preservation the calculated energy charge was significantly higher after 10 and 24 h of oscillating perfusion compared to the simple storage group. In addition, a significant energy charge loading was demonstrated by 10 h oscillating perfusion compared to the initial value prior to perfusion. The oscillating, computer-controlled perfusion permits continuous monitoring of perfusate temperature, O2 consumption, pCO2, portal vein pressure…

MalePathologymedicine.medical_specialtyBiomedical EngineeringCold storageBlood PressureIn Vitro TechniquesGeneral Biochemistry Genetics and Molecular BiologypCO2Oxygen ConsumptionAdenine nucleotideOscillometryRats Inbred BNmedicineAnimalsEnergy chargeCryopreservationL-Lactate DehydrogenaseChemistryAdenine NucleotidesGeneral MedicineOrgan PreservationHydrogen-Ion Concentrationmedicine.diseaseLiver GlycogenRatsTransplantationCold TemperaturePerfusionLiverEvaluation Studies as TopicReperfusion InjurySample collectionGeneral Agricultural and Biological SciencesReperfusion injuryPerfusionGlycolysisBiomedical engineeringCryobiology
researchProduct