Search results for "Scintillator"
showing 10 items of 172 documents
A novel experimental system for the KDK measurement of the 40K decay scheme relevant for rare event searches
2020
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source …
A time-differential Mössbauer emission spectrometer with high efficiency and high time resolution
1986
A high-efficiency, high rate-capability, computer-based measuring setup for Time-Differential Mossbauer Spectroscopy was constructed. Applying NaI(Tl) and plastic scintillators for the detection of the 14.4 keV and 122 keV γ-radiation respectively, a superior timing (2, 3 ns FWHM) was achieved by a “fast-fast-ultra fast” timing method developed for that purpose.
Measurement of propagation time dispersion in a scintillator
2007
One contribution to the time resolution of a scintillation detector is the signal time spread due to path length variations of the detected photons from a point source. In an experimental study a rectangular scintillator was excited by means of a fast pulsed ultraviolet laser at different positions along its longitudinal axis. Timing measurements with a photomultiplier tube in a detection plane displaced from the scintillator end face showed a correlation between signal time and tube position indicating only a small distortion of photon angles during transmission. The data is in good agreement with a Monte Carlo simulation used to compute the average photon angle with respect to the detecti…
Neutron detection and γ-ray suppression using artificial neural networks with the liquid scintillators BC-501A and BC-537
2019
Abstract In this work we present a comparison between the two liquid scintillators BC-501A and BC-537 in terms of their performance regarding the pulse-shape discrimination between neutrons and γ rays. Special emphasis is put on the application of artificial neural networks . The results show a systematically higher γ -ray rejection ratio for BC-501A compared to BC-537 applying the commonly used charge comparison method. Using the artificial neural network approach the discrimination quality was improved to more than 95% rejection efficiency of γ rays over the energy range 150 to 1000 keV for both BC-501A and BC-537. However, due to the larger light output of BC-501A compared to BC-537, neu…
Measurements of the muon component of extensive air showers at 320m.w.e. underground
2003
Abstract The ALEPH detector at LEP has been supplemented with five scintillator telescopes to measure the muon component of cosmic ray air showers underground. The emphasis of the present analysis of a new data set is to measure coincidences over distances up to about 1 km which are sensitive to the forward production of hadronic interactions and the chemical composition of primary cosmic rays in the energy range around 1015 eV. First results indicate that the observed decoherence curve of muons is compatible with a light primary composition and the arrival directions of muons show no obvious clustering in galactic coordinates.
A highly-segmented ΔE-time-of-flight wall as forward detector of the 4π-system for charged particles at the SIS/ESR accelerator
1993
Abstract At the SIS/ESR accelerator facility at GSI in Darmstadt the 4π-detector system FOPI is under construction at present. It is designed for the investigation of central collisions of heavy ions in the energy range up to 2 A GeV. As phase I of this detector a forward wall has been built and used in various experiments. It comprizes a total number of 764 scintillators with an additional shell of 188 thin ΔE -detectors in front of it and covers the full azimuth of the polar angles from 1° to 30°. The velocity and the nuclear charge of the fragments are determined by a combined time-of-flight and ΔE measurement.
Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly
2015
Abstract In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope , UBAT, during the preliminary calibration with MAPMTs of 64 2.88 × 2.88 mm2 pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode . The simulation reproduced more than 70% of the crosstalk and explained it as a consequence of the total reflection produced by the photocathode. The result…
WITHDRAWN: A scintillator based time-of-flight hodoscope with a new type of emitter follower divider
2004
Pulse shape analysis of liquid scintillators for neutron studies
2002
The acquisition of signals from liquid scintillators with Flash ADC of high sampling rate ð 1G S=sÞ has been investigated. The possibility to record the signal waveform is of great advantage in studies with g’s and neutrons in a high count-rate environment, as it allows to easily identify and separate pile-up events. The shapes of pulses produced by g-rays and neutrons have been studied for two different liquid scintillators, NE213 and C6D6: A 1-parameter fitting procedure is proposed, which allows to extract information on the particle type and energy. The performance of this method in terms of energy resolution and n=g discrimination is analyzed, together with the capability to identify a…
Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study
2015
[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…