Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
2019
Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…
A New Method for Revision of Encapsulated Blebs after Trabeculectomy: Combination of Standard Bleb Needling with Transconjunctival Scleral Flap Sutur…
2016
Purpose A simple needling procedure is the standard method for restoring the function of an encapsulated bleb after trabeculectomy. However, postoperative hypotony represents a possible hazard. This study describes a new surgical approach for treating encapsulated blebs with reduced risk of early postoperative hypotony: bleb needling combined with transconjunctival sutures tightening the scleral flap directly. Methods The study included two groups of 23 patients with failing bleb following trabeculectomy: “Group 1” underwent simple needling revision of the filtering bleb and served as a control group, while “Group 2” received needling revision with additional transconjunctival scleral flap …
Corneo-scleral contact lens in a piggyback system for keratoconus: A case report.
2017
Purpose: We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. Methods: A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a s…
Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.
2020
OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…
Ocular Phenotype of Relaxin Gene Knockout (Rln-/-) Mice
2020
Purpose: To test if relaxin deficiency affects ocular structure and function we investigated expression of relaxin (Rln) and RXFP receptors (Rxfp1, Rxfp2), and compared ocular phenotypes in relaxin gene knockout (Rln-/- ) and wild type (Rln+/+ ) mice. Materials and Methods: Rln, Rxfp1 and Rxfp2 mRNA expression was detected in ocular tissues of Rln+/+ mice using RT-PCR. The eyes of 11 Rln-/- and 5 Rln+/+ male mice were investigated. Corneal and retinal thickness was assessed using optical coherence tomography. Intraocular pressure was measured using a rebound tonometer. Retinal, choroidal and sclera morphology and thickness were evaluated histologically. Eyes were collected and fixed for imm…
XEN-augmented Baerveldt Implantation for Refractory Childhood Glaucoma: A Retrospective Case Series
2019
Background Tube implants can lead to long-term decompensation of the cornea after decades, in particular in complicated childhood glaucoma, because of a variety of causes including contact between the tube tip and the corneal endothelium. The augmentation of a XEN implant with a Baerveldt (250) tube implant, introduced 2016 by Mermoud et al for refractory glaucoma in adult patients, may reduce this risk in children. In our retrospective study, we report on the XEN-augmented Baerveldt (250) tube implant in children. Patients and methods Ten consecutive patients with refractory childhood glaucoma who underwent XEN-augmented Baerveldt implantation by a single surgeon (F.G.) between January 201…
Corneal Biomechanics, Retinal Nerve Fiber Layer, and Optic Disc in Children
2014
Purpose. To evaluate the possible associations between corneal biomechanical parameters, optic disc morphology, and retinal nerve fiber layer (RNFL) thickness in healthy white Spanish children. Methods. This cross-sectional study included 100 myopic children and 99 emmetropic children as a control group, ranging in age from 6 to 17 years. The Ocular Response Analyzer was used to measure corneal hysteresis (CH) and corneal resistance factor. The optic disc morphology and RNFL thickness were assessed using posterior segment optical coherence tomography (Cirrus HD-OCT). The axial length was measured using an IOLMaster, whereas the central corneal thickness was measured by anterior segment opti…
PE-11, a peptide derived from chromogranin B, in the rat eye.
2010
The aim of the study was to investigate the presence and distribution of PE-11, a peptide derived from chromogranin B, in the rat eye. For this purpose, newborn rats were injected with a single dosage of 50mg/kg capsaicin subcutaneously under the neck fold and after three months, particular eye tissues were dissected and the concentration of PE-11-like immunoreactivity was determined by radioimmunoassay. Furthermore, PE-11-like immunoreactivities were characterized in an extract of the rat eye by reversed phase HPLC. Then, the distribution pattern of PE-11 was investigated in the rat eye and rat trigeminal ganglion by immunofluorescence. As a result, PE-11 was present in each tissue of the …
Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism
2017
Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…
Severe scleral dellen as an early complication of pterygium excision with simple conjunctival closure and review of the literature
2014
Descrevemos um paciente com "dellen" escleral agudo (SD) após excisão de pterígio com fechamento conjuntival simples. Uma revisão adicional da literatura médica sobre SD precoce após a cirurgia de pterígio também é realizada. Este caso descreve um homem de 45 anos de idade, que apresentou SD grave, sete dias após a cirurgia de pterígio com cauterização mínima de vasos episclerais e fechamento conjuntival simples. Nenhuma outra terapia adjuvante foi utilizada no intraoperatório. O paciente recusou-se à cobertura de retalho conjuntival da lesão. Portanto, o tratamento médico consistiu em pomada antibiótica, oclusão e acompanhamento diário. Após sete dias, a oclusão foi mudada para a lubrifica…