Search results for "Secondary Ion Mass Spectrometry"
showing 10 items of 38 documents
Further characterisation of the 91500 zircon crystal
2004
This paper reports the results from a second characterisation of the 91500 zircon, including data from electron probe microanalysis, laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS), secondary ion mass spectrometry (SIMS) and laser fluorination analyses. The focus of this initiative was to establish the suitability of this large single zircon crystal for calibrating in situ analyses of the rare earth elements and oxygen isotopes, as well as to provide working values for key geochemical systems. In addition to extensive testing of the chemical and structural homogeneity of this sample, the occurrence of banding in 91500 in both backscattered electron and cathodolumines…
Elaboration and characterization of barium silicate thin films.
2008
International audience; Room temperature depositions of barium on a thermal silicon oxide layer were performed in ultra high vacuum (UHV). In-situ X-ray photoelectron spectroscopy (XPS) analyses were carried out as well after exposure to air as after subsequent annealings. These analyses were ex-situ completed by secondary ion mass spectrometry (SIMS) profiles and transmission electron microscopy (TEM) cross-sectional images. The results showed that after air exposure, the barium went carbonated. Annealing at sufficient temperature permitted to decompose the carbonate to benefit of a barium silicate. The silicate layer was formed by interdiffusion of barium with the initial SiO2 layer.
Mechanisms Involved by Reactive Elements upon High Temperature Chromia Scale Growth
2001
The influence of Y 2 O 3 , Pr 2 O 3 , Nd 2 O 3 , Sm 2 O 3 and Yb 2 O 3 coatings on Fe-30Cr alloy oxidation behaviour was investigated at 1000°C in air under atmospheric pressure. Isothermal exposures indicated that the Y 2 O 3 coating was the most protective after 100 hours. Pr 2 O 3 , Nd 2 O 3 and Sm 2 O 3 coatings were less effective, but the less beneficial effect was observed when Yb 2 O 3 coating was applied onto the Fe-Cr alloy surface. Two-stage oxidation experiments in 16 O 2 and then 18 O 2 were performed to get information about the chromia growth phenomena with and without reactive elements. The 18 O-tracer distribution was determined by secondary ion mass spectrometry (SIMS) and…
Bio-imaging with the helium-ion microscope: A review
2021
Scanning helium-ion microscopy (HIM) is an imaging technique with sub-nanometre resolution and is a powerful tool to resolve some of the tiniest structures in biology. In many aspects, the HIM resembles a field-emission scanning electron microscope (FE-SEM), but the use of helium ions rather than electrons provides several advantages, including higher surface sensitivity, larger depth of field, and a straightforward charge-compensating electron flood gun, which enables imaging of non-conductive samples, rendering HIM a promising high-resolution imaging technique for biological samples. Starting with studies focused on medical research, the last decade has seen some particularly spectacular …
Corrosion Protection of Steel with Oxide Nanolaminates Grown by Atomic Layer Deposition
2011
Atomic layer deposited (ALD) aluminum and tantalum oxide (Al 2 O 3 and Ta 2 O 5 ) and their nanolaminates were applied as corrosion protection coatings on AISI 52100 steel. The aim was to combine the good sealing properties of Al 2 O 3 with the chemical stability of Ta 2 O 5 and to optimize the coating architecture in order to obtain the best possible long-term durability. Coating composition and morphology were studied with time-of-flight elastic recoil detection analysis (ToF-ERDA), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and field emission scanning electron microscopy (FESEM) and energy dispersive x-ray spectrometry (EDS). Electrochemical properties were studied with vo…
Kinetics of Bulk Lifetime Degradation in Float‐Zone (FZ) Silico n : Fast Activation and Annihilation of Grown‐In Defects and the Role of Hydrogen vs …
2020
Float-zone (FZ) silicon often has grown-in defects that are thermally activated in a broad temperature window (≈300–800 °C). These defects cause efficient electron-hole pair recombination, which deteriorates the bulk minority carrier lifetime and thereby possible photovoltaic conversion efficiencies. Little is known so far about these defects which are possibly Si-vacancy/nitrogen-related (VxNy). Herein, it is shown that the defect activation takes place on sub-second timescales, as does the destruction of the defects at higher temperatures. Complete defect annihilation, however, is not achieved until nitrogen impurities are effused from the wafer, as confirmed by secondary ion mass spectro…
Status of the project TRAPSENSOR: Performance of the laser-desorption ion source
2013
Abstract Penning traps provide mass measurements on atomic nuclei with the highest accuracy and sensitivity. Depending on the experiment and on the physics goal, a relative mass uncertainty varying from 10 −7 to below 10 −11 is required. Regarding sensitivity, the use of only one ion for the measurement is crucial, either to perform mass measurements on superheavy elements (SHE), or to reach δ m / m ≈ 10 - 11 in order to contribute to the direct determination of the mass of the electron-antineutrino with accurate mass measurements on specific nuclei. This has motivated the development of a new technique called Quantum Sensor based on a laser-cooled ion stored in a Penning trap, to perform m…
A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams
1997
Abstract A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 10 5 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.
Versatile use of ion beams for diffusion studies by the modified radiotracer technique
2004
Abstract In the modified radiotracer technique ion beams within a broad energy range are employed. They include energetic light particles ensuring radioactive isotope production via nuclear reactions, keV-ion implantation of radiotracers and sputtering by low energy heavy ions for depth profiling. If the involved ion–solid interactions are properly taken into account, the technique provides an effective means for solid-state diffusion studies under demanding conditions. The various aspects related to the modified radiotracer technique are surveyed and discussed. The reliability of the procedure is demonstrated by comparisons with corresponding profiles obtained by secondary ion mass spectro…
Recent Exploits of the ISOLTRAP Mass Spectrometer
2013
Abstract The Penning-trap mass spectrometer ISOLTRAP, located at the isotope-separator facility ISOLDE (CERN), is presented in its current form taking into account technical developments since 2007. Three areas of developments are presented. The reference ion sources have been modified to guarantee a sufficient supply of reference ions for mass measurements and systematic studies. Different excitation schemes have been investigated for manipulation of the ion motion in the Penning trap, to enhance either the purification or measurement process. A multi-reflection time-of-flight mass separator has been implemented and can now be routinely used for purification and as a versatile tool for bea…