Search results for "Secondary Ion Mass Spectrometry"

showing 10 items of 38 documents

Further characterisation of the 91500 zircon crystal

2004

This paper reports the results from a second characterisation of the 91500 zircon, including data from electron probe microanalysis, laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS), secondary ion mass spectrometry (SIMS) and laser fluorination analyses. The focus of this initiative was to establish the suitability of this large single zircon crystal for calibrating in situ analyses of the rare earth elements and oxygen isotopes, as well as to provide working values for key geochemical systems. In addition to extensive testing of the chemical and structural homogeneity of this sample, the occurrence of banding in 91500 in both backscattered electron and cathodolumines…

In situLaser ablation010504 meteorology & atmospheric sciencesAnalytical chemistryMineralogyGeologyCathodoluminescence010502 geochemistry & geophysicsLaserMass spectrometry01 natural sciencesIsotopes of oxygenlaw.inventionSecondary ion mass spectrometryGeochemistry and PetrologylawGeology0105 earth and related environmental sciencesZircon
researchProduct

Elaboration and characterization of barium silicate thin films.

2008

International audience; Room temperature depositions of barium on a thermal silicon oxide layer were performed in ultra high vacuum (UHV). In-situ X-ray photoelectron spectroscopy (XPS) analyses were carried out as well after exposure to air as after subsequent annealings. These analyses were ex-situ completed by secondary ion mass spectrometry (SIMS) profiles and transmission electron microscopy (TEM) cross-sectional images. The results showed that after air exposure, the barium went carbonated. Annealing at sufficient temperature permitted to decompose the carbonate to benefit of a barium silicate. The silicate layer was formed by interdiffusion of barium with the initial SiO2 layer.

Materials scienceAnnealing (metallurgy)Ultra-high vacuumAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_element02 engineering and technology01 natural scienceschemistry.chemical_compoundIn-situ analysesX-ray photoelectron spectroscopyStructural Biology0103 physical sciencesXPSGeneral Materials ScienceThin filmBarium silicateSilicon oxide010302 applied physicstechnology industry and agricultureBariumCell Biology021001 nanoscience & nanotechnologySilicateSecondary ion mass spectrometrychemistry0210 nano-technology
researchProduct

Mechanisms Involved by Reactive Elements upon High Temperature Chromia Scale Growth

2001

The influence of Y 2 O 3 , Pr 2 O 3 , Nd 2 O 3 , Sm 2 O 3 and Yb 2 O 3 coatings on Fe-30Cr alloy oxidation behaviour was investigated at 1000°C in air under atmospheric pressure. Isothermal exposures indicated that the Y 2 O 3 coating was the most protective after 100 hours. Pr 2 O 3 , Nd 2 O 3 and Sm 2 O 3 coatings were less effective, but the less beneficial effect was observed when Yb 2 O 3 coating was applied onto the Fe-Cr alloy surface. Two-stage oxidation experiments in 16 O 2 and then 18 O 2 were performed to get information about the chromia growth phenomena with and without reactive elements. The 18 O-tracer distribution was determined by secondary ion mass spectrometry (SIMS) and…

Materials scienceAtmospheric pressureMechanical EngineeringDiffusionHigh-temperature corrosionMetallurgyAlloyAnalytical chemistrychemistry.chemical_elementengineering.materialCondensed Matter PhysicsChromiaSecondary ion mass spectrometryChromiumCoatingchemistryMechanics of MaterialsengineeringGeneral Materials ScienceMaterials Science Forum
researchProduct

Bio-imaging with the helium-ion microscope: A review

2021

Scanning helium-ion microscopy (HIM) is an imaging technique with sub-nanometre resolution and is a powerful tool to resolve some of the tiniest structures in biology. In many aspects, the HIM resembles a field-emission scanning electron microscope (FE-SEM), but the use of helium ions rather than electrons provides several advantages, including higher surface sensitivity, larger depth of field, and a straightforward charge-compensating electron flood gun, which enables imaging of non-conductive samples, rendering HIM a promising high-resolution imaging technique for biological samples. Starting with studies focused on medical research, the last decade has seen some particularly spectacular …

Materials scienceBiological objectshimIonofluorescenseGeneral Physics and AstronomyBio-imagingNanotechnology02 engineering and technologyReviewmikroskopialcsh:Chemical technologylcsh:Technology03 medical and health sciencesBiological specimenBio imagingHelium-ion microscopyhelium-ion microscopyMicroscopyNanotechnologyGeneral Materials ScienceHigh resolutionlcsh:TP1-1185Depth of fieldElectrical and Electronic Engineeringlcsh:Science030304 developmental biology0303 health sciencesFlood gunhigh resolutionlcsh:THIMionofluorescense021001 nanoscience & nanotechnologyBiological materialslcsh:QC1-999him-simsSecondary ion mass spectrometryflood gunNanosciencekuvantaminenbio-imagingvirologiaHIM-SIMSlcsh:Qmikrobiologia0210 nano-technologyField ion microscopelcsh:PhysicssolubiologiaBeilstein Journal of Nanotechnology
researchProduct

Corrosion Protection of Steel with Oxide Nanolaminates Grown by Atomic Layer Deposition

2011

Atomic layer deposited (ALD) aluminum and tantalum oxide (Al 2 O 3 and Ta 2 O 5 ) and their nanolaminates were applied as corrosion protection coatings on AISI 52100 steel. The aim was to combine the good sealing properties of Al 2 O 3 with the chemical stability of Ta 2 O 5 and to optimize the coating architecture in order to obtain the best possible long-term durability. Coating composition and morphology were studied with time-of-flight elastic recoil detection analysis (ToF-ERDA), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and field emission scanning electron microscopy (FESEM) and energy dispersive x-ray spectrometry (EDS). Electrochemical properties were studied with vo…

Materials scienceOxide02 engineering and technologyengineering.material01 natural sciencesCorrosionAtomic layer depositionchemistry.chemical_compoundCoating0103 physical sciencesMaterials ChemistryElectrochemistryta116010302 applied physicsta114Renewable Energy Sustainability and the EnvironmentMetallurgy021001 nanoscience & nanotechnologyCondensed Matter PhysicsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsDielectric spectroscopyElastic recoil detectionSecondary ion mass spectrometryChemical engineeringchemistryengineering0210 nano-technologyLayer (electronics)Journal of the Electrochemical Society
researchProduct

Kinetics of Bulk Lifetime Degradation in Float‐Zone (FZ) Silico n : Fast Activation and Annihilation of Grown‐In Defects and the Role of Hydrogen vs …

2020

Float-zone (FZ) silicon often has grown-in defects that are thermally activated in a broad temperature window (≈300–800 °C). These defects cause efficient electron-hole pair recombination, which deteriorates the bulk minority carrier lifetime and thereby possible photovoltaic conversion efficiencies. Little is known so far about these defects which are possibly Si-vacancy/nitrogen-related (VxNy). Herein, it is shown that the defect activation takes place on sub-second timescales, as does the destruction of the defects at higher temperatures. Complete defect annihilation, however, is not achieved until nitrogen impurities are effused from the wafer, as confirmed by secondary ion mass spectro…

Materials scienceSiliconPassivationfloat-zone siliconResearchInstitutes_Networks_Beacons/photon_science_instituteTKchemistry.chemical_elementnitrogen vacancy centers02 engineering and technologyPhoton Science Institute01 natural scienceslaw.inventionlaw0103 physical sciencesSolar cellMaterials ChemistryWaferElectrical and Electronic Engineeringdefects010302 applied physicsDangling bondSurfaces and InterfacesCarrier lifetimeFloat-zone silicon021001 nanoscience & nanotechnologyCondensed Matter PhysicsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsSecondary ion mass spectrometryfloat‐zone siliconphotovoltaicschemistryChemical physicsbulk lifetime0210 nano-technology
researchProduct

Status of the project TRAPSENSOR: Performance of the laser-desorption ion source

2013

Abstract Penning traps provide mass measurements on atomic nuclei with the highest accuracy and sensitivity. Depending on the experiment and on the physics goal, a relative mass uncertainty varying from 10 −7 to below 10 −11 is required. Regarding sensitivity, the use of only one ion for the measurement is crucial, either to perform mass measurements on superheavy elements (SHE), or to reach δ m / m ≈ 10 - 11 in order to contribute to the direct determination of the mass of the electron-antineutrino with accurate mass measurements on specific nuclei. This has motivated the development of a new technique called Quantum Sensor based on a laser-cooled ion stored in a Penning trap, to perform m…

Nuclear and High Energy PhysicsChemistry010401 analytical chemistryQuantum sensorMass spectrometryPenning trap7. Clean energy01 natural sciencesIon source0104 chemical sciencesComputational physicsIonSecondary ion mass spectrometry0103 physical sciencesIon trapTime-of-flight mass spectrometryAtomic physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams

1997

Abstract A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 10 5 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.

Nuclear and High Energy PhysicsIon beamChemistryMass spectrometryPenning trapIon gunISOLTRAPIon sourceNuclear physicsSecondary ion mass spectrometryPhysics::Accelerator PhysicsIon trapDetectors and Experimental TechniquesAtomic physicsNuclear ExperimentInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Versatile use of ion beams for diffusion studies by the modified radiotracer technique

2004

Abstract In the modified radiotracer technique ion beams within a broad energy range are employed. They include energetic light particles ensuring radioactive isotope production via nuclear reactions, keV-ion implantation of radiotracers and sputtering by low energy heavy ions for depth profiling. If the involved ion–solid interactions are properly taken into account, the technique provides an effective means for solid-state diffusion studies under demanding conditions. The various aspects related to the modified radiotracer technique are surveyed and discussed. The reliability of the procedure is demonstrated by comparisons with corresponding profiles obtained by secondary ion mass spectro…

Nuclear reactionNuclear and High Energy PhysicsRange (particle radiation)PhotonIon beamChemistryAnalytical chemistry010403 inorganic & nuclear chemistry01 natural sciences7. Clean energy0104 chemical sciencesIonSecondary ion mass spectrometrySputtering0103 physical sciencesDiffusion (business)010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Recent Exploits of the ISOLTRAP Mass Spectrometer

2013

Abstract The Penning-trap mass spectrometer ISOLTRAP, located at the isotope-separator facility ISOLDE (CERN), is presented in its current form taking into account technical developments since 2007. Three areas of developments are presented. The reference ion sources have been modified to guarantee a sufficient supply of reference ions for mass measurements and systematic studies. Different excitation schemes have been investigated for manipulation of the ion motion in the Penning trap, to enhance either the purification or measurement process. A multi-reflection time-of-flight mass separator has been implemented and can now be routinely used for purification and as a versatile tool for bea…

Penning-trap mass spectrometryNuclear and High Energy PhysicsLarge Hadron ColliderIon beam analysisChemistry010401 analytical chemistryMeasurement of pure ion ensembles[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap01 natural sciencesISOLTRAPMulti-reflection time-of-flight mass separator0104 chemical sciencesSecondary ion mass spectrometryNuclear physicsIon-beam analysis0103 physical sciencesBeam purificationIon trapAtomic physics010306 general physicsNuclear ExperimentInstrumentationHybrid mass spectrometer
researchProduct