Search results for "Senso"

showing 10 items of 4750 documents

Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.

2001

To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…

AdultMaleIntraocular pressuremedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIntraocular lensCataractCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansMinimally Invasive Surgical ProceduresProspective StudiesSclerocorneaIntraocular PressureAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryScleraOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessSurgical incisionScleraJournal of cataract and refractive surgery
researchProduct

Falsely elevated intraocular pressure due to increased central corneal thickness

1999

PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…

AdultMaleIntraocular pressuremedicine.medical_specialtyprimary open-angle glaucomaAdolescentgenetic structuresEye diseaseOcular hypertensionGlaucomaCorneaCellular and Molecular NeurosciencePredictive Value of TestsCorneaOphthalmologyDiabetes mellitusHumansMedicineFalse Positive ReactionsProspective StudiesCorneal pachymetry[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansProspective cohort studyAgedUltrasonographyAged 80 and overmedicine.diagnostic_testdiabetesbusiness.industryMiddle Agedmedicine.diseaseSensory Systemseye diseasesSurgeryOphthalmologymedicine.anatomical_structureocular hypertensionFemalecentral corneal thicknesssense organsbusinessGlaucoma Open-Angle[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyintraocular pressure
researchProduct

KIAA0556 is a novel ciliary basal body component mutated in Joubert syndrome

2015

Background Joubert syndrome (JBTS) and related disorders are defined by cerebellar malformation (molar tooth sign), together with neurological symptoms of variable expressivity. The ciliary basis of Joubert syndrome related disorders frequently extends the phenotype to tissues such as the eye, kidney, skeleton and craniofacial structures. Results Using autozygome and exome analyses, we identified a null mutation in KIAA0556 in a multiplex consanguineous family with hallmark features of mild Joubert syndrome. Patient-derived fibroblasts displayed reduced ciliogenesis potential and abnormally elongated cilia. Investigation of disease pathophysiology revealed that Kiaa0556-/- null mice possess…

AdultMaleK04F10.2KIAA0556MicrotubuleMicrotubulesRetinaMiceJoubert syndromeCerebellumAnimalsHumansAbnormalities MultipleExomeCiliaEye AbnormalitiesSensory disorders Radboud Institute for Molecular Life Sciences [Radboudumc 12]Caenorhabditis elegansChildCells CulturedAdenosine TriphosphatasesADP-Ribosylation FactorsResearchBrainMetabolic Disorders Radboud Institute for Molecular Life Sciences [Radboudumc 6]Kidney Diseases CysticBasal BodiesPedigreeMice Inbred C57BLRenal disorders Radboud Institute for Molecular Life Sciences [Radboudumc 11]Basal bodyChild PreschoolMutationFemaleKataninMicrotubule-Associated ProteinsProtein BindingGenome Biology
researchProduct

Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.

2012

To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentCorneal StromaVision DisordersVisual AcuityComa (optics)Power vectorKeratoconusRefraction OcularCohort StudiesProsthesis ImplantationYoung AdultOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesAlpins methodAgedIntrastromal corneal ring segmentbusiness.industryCorneal TopographyProstheses and ImplantsMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologySurgeryFemalesense organsLaser TherapyCorneal ringbusinessJournal of cataract and refractive surgery
researchProduct

Amplitudes of laser evoked potential recorded from primary somatosensory, parasylvian and medial frontal cortex are graded with stimulus intensity

2003

Intensity encoding of painful stimuli in many brain regions has been suggested by imaging studies which cannot measure electrical activity of the brain directly. We have now examined the effect of laser stimulus intensity (three energy levels) on laser evoked potentials (LEPs) recorded directly from the human primary somatosensory (SI), parasylvian, and medial frontal cortical surfaces through subdural electrodes implanted for surgical treatment of medically intractable epilepsy. LEP N2* (early exogenous/stimulus-related potential) and LEP P2** (later endogenous potential) amplitudes were significantly related to the laser energy levels in all regions, although differences between regions w…

AdultMaleLaser-Evoked PotentialsPainStimulus (physiology)Somatosensory systemFunctional LateralityNuclear magnetic resonanceSeizuresReaction TimemedicineNoxious stimulusHumansEvoked potentialElectrodesEvoked PotentialsAnterior cingulate cortexPain MeasurementBrain MappingChemistryLasersDose-Response Relationship RadiationSomatosensory CortexMiddle AgedFrontal LobeElectrophysiologyAnesthesiology and Pain Medicinemedicine.anatomical_structureNeurologySomatosensory evoked potentialFemaleNeurology (clinical)NeurosciencePain
researchProduct

Dipole source analyses of laser evoked potentials obtained from subdural grid recordings from primary somatic sensory cortex

2011

The cortical potentials evoked by cutaneous application of a laser stimulus (laser evoked potentials, LEP) often include potentials in the primary somatic sensory cortex (S1), which may be located within the subdivisions of S1 including Brodmann areas 3A, 3B, 1, and 2. The precise location of the LEP generator may clarify the pattern of activation of human S1 by painful stimuli. We now test the hypothesis that the generators of the LEP are located in human Brodmann area 1 or 3A within S1. Local field potential (LFP) source analysis of the LEP was obtained from subdural grids over sensorimotor cortex in two patients undergoing epilepsy surgery. The relationship of LEP dipoles was compared wi…

AdultMaleLaser-Evoked PotentialsPhysiologySubdural SpaceStimulus (physiology)Somatosensory systemlaw.inventionYoung AdultlawEvoked Potentials SomatosensorymedicineHumansSubdural spaceDipole sourcePhysicsLasersGeneral NeuroscienceElectric ConductivityArticlesSomatosensory CortexCutaneous applicationLaserElectric StimulationElectrodes Implantedmedicine.anatomical_structurePrimary somatic sensory cortexFemaleNeuroscienceJournal of Neurophysiology
researchProduct

Changes in pattern induced flicker colors are mediated by the blue-yellow opponent process.

1992

The colors of Benham's Top [pattern induced flicker colors (PIFCs)] were matched with color stimuli provided by a computer aided color mixer. Subjects viewed a series of specifically modified black and white disks and matched the resulting subjective color with a comparison field containing the color generated by additive mixing. Different phase relations between the apparently colored ring and the surround were tested. The color loci of all PIFCs were found to lie on a plane in receptor three-space which is given by the axis of the shortwave receptor excitation and a vector given by combining the middle and long wave receptor excitation directions in a fixed ratio of nearly 1:1. From the o…

AdultMaleLightColor visionPhase (waves)OpticsmedicinePsychophysicsHumansColor perception testPhotoreceptor CellsPhysicsColor Perception Testsmedicine.diagnostic_testbusiness.industryPlane (geometry)FlickerOpponent processSensory SystemsOphthalmologyColoredPattern Recognition VisualFemalebusinessColor PerceptionPhotic StimulationVision research
researchProduct

Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…

2007

Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…

AdultMaleLightPsychometricsIntraclass correlationLensletDiagnostic Techniques OphthalmologicalEyeRefraction OcularModels BiologicalSensitivity and SpecificityStandard deviationOpticsmedicineImage Processing Computer-AssistedHumansScattering RadiationMathematicsbusiness.industryObjective measurementCentroidReproducibility of ResultsSmall sampleRepeatabilitySensory SystemsOphthalmologymedicine.anatomical_structureOptometrySurgeryHuman eyeFemalebusinessJournal of cataract and refractive surgery
researchProduct

Color and lightness constancy in different perceptual tasks

1998

Color and lightness constancy with respect to changing illumination was studied with three different perceptual tasks: ranking of colored papers according (1) to their lightness and (2) to their chromatic similarity in photopic, mesopic, and scotopic states of adaptation, and (3) recognition of remembered colored papers after changes of illumination in photopic vision. Constancy was found in the second task, only. Excitations of light receptors and luminance channels were computed to simulate the empirical rank orders. Results of the first task can be predicted with the hypothesis that luminance channels are activated, if lightness is asked for. Sequences arranged with respect to chromatic …

AdultMaleLightnessGeneral Computer ScienceMesopic visionColor visionColorAdaptation (eye)Discrimination LearningHumansComputer visionScotopic visionMathematicsColor constancyAdaptation Ocularbusiness.industryCIECAM02Sensory ThresholdsRetinal Cone Photoreceptor CellsFemaleArtificial intelligencebusinessColor PerceptionPhotic StimulationBiotechnologyPhotopic visionBiological Cybernetics
researchProduct

Tapping doesn't help: Synchronized self-motion and judgments of musical tempo.

2019

For both musicians and music psychologists, beat rate (BPM) has often been regarded as a transparent measure of musical speed or tempo, yet recent research has shown that tempo is more than just BPM. In a previous study, London, Burger, Thompson, and Toiviainen (Acta Psychologica, 164, 70–80, 2016) presented participants with original as well as “time-stretched” versions of classic R&B songs; time stretching slows down or speeds up a recording without changing its pitch or timbre. In that study we discovered a tempo anchoring effect (TAE): Although relative tempo judgments (original vs. time-stretched versions of the same song) were correct, they were at odds with BPM rates of each stimulus…

AdultMaleLinguistics and LanguageTime FactorsAdolescentMovementAudio time-scale/pitch modificationExperimental and Cognitive PsychologyRhythmMusicalStimulus (physiology)Perception–action dissociation050105 experimental psychologyLanguage and LinguisticsPerceptual sharpeningFingersTime for Action: Reaching for a Better Understanding of the Dynamics of Cognition03 medical and health sciencesJudgmentMotionYoung Adult0302 clinical medicineRhythmSensorimotor synchronizationSelf motionHumans0501 psychology and cognitive sciencesTempo illusion05 social sciencesSensory SystemsAuditory PerceptionTappingFemalePsychologyTimbreBeat (music)030217 neurology & neurosurgeryMusicCognitive psychologyAttention, perceptionpsychophysics
researchProduct