Search results for "Sensor"
showing 10 items of 4594 documents
First results from electrical qualification measurements on DEPFET pixel detector
2010
We report on the first results from a new setup for electrical qualification measurements of DEPFET pixel detector matrices. In order to measure the transistor properties of all pixels, the DEPFET device is placed into a benchtest setup and electrically contacted via a probecard. Using a switch matrix, each pixel of the detector array can be addressed individually for characterization. These measurements facilitate to pre-select the best DEPFET matrices as detector device prior to the mounting of the matrix and allow to investigate topics like the homogeneity of transistor parameters on device, wafer and batch level in order to learn about the stability and reproducibility of the production…
The wide field imager for the International X-ray Observatory
2009
The large collecting area of the X-ray optics on the International X-ray Observatory (IXO), their good angular resolution, the wide bandwidth of X-ray energies and the high radiation tolerance required for the X-ray detectors in the focal plane have stimulated a new development of devices which unify all those science driven specifications in one single detector. The concept of a monolithic, back-illuminated silicon active pixel sensor (APS) based on the DEPFET structure is proposed for the IXO mission, being a fully depleted, back-illuminated 450 μm thick detector with a physical size of about 10 × 10 cm 2 corresponding to the 18 arcmin field of view. The backside will be covered with an i…
Small field motion detection in goldfish is red-green color blind and mediated by the M-cone type
2007
Large field motion detection in goldfish, measured in the optomotor response, is based on the L-cone type, and is therefore color-blind (Schaerer & Neumeyer, 1996). In experiments using a two-choice training procedure, we investigated now whether the same holds for the detection of a small moving object (size: 8 mm diameter; velocity: 7 cm/s). In initial experiments, we found that goldfish did not discriminate between a moving and a stationary stimulus, obviously not taking attention to the cue “moving.” Therefore, random dot patterns were used in which the stimulus was visible only when moving. Using black and white random dot patterns with variable contrast between 0.2 and 1, we found…
Pumping of single electrons with a traveling wave
1995
Abstract We describe the operation and performance of a one-dimensional chain of small metallic islands whose potentials are modulated in a wave-like manner. The sinusoidal voltages, applied to the gate electrodes, carry individual charges coherently through the array. In practice, the wave-like potential is induced on the gates by a surface acoustic wave (SAW) traveling on a piezoelectric substrate. The resulting transfer of charges should produce a DC current I = ± ef through the chain, where f is the frequency of the wave and the sign ofthe current depends on the value of the common DC bias of the islands as well as on the direction of the wave propagation. We observe, however, a much sm…
The X-ray Integral Field Unit (X-IFU) for Athena
2014
Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics princi…
Enhanced depth of field integral imaging with sensor resolution constraints.
2009
One of the main challenges in integral imaging is to overcome the limited depth of field. Although it is widely assumed that such limitation is mainly imposed by diffraction due to lenslet imaging, we show that the most restricting factor is the pixelated structure of the sensor (CCD). In this context, we demonstrate that by proper reduction of the fill factor of pickup microlenses, the depth of field can be substantially improved with no deterioration of lateral resolution.
Focus on modern frontiers of matter wave optics and interferometry
2012
The level of experimental control and the detailed theoretical understanding of matter wave physics have led to a renaissance of experiments testing the very foundations of quantum mechanics and general relativity, as well as to applications in metrology. A variety of interferometric quantum sensors surpasses, or will surpass, the limits of their classical counterparts, for instance in the measurement of frequency and time or forces such as accelerations due to rotation and gravity with applications in basic science, navigation and the search for natural resources. The collection of original articles published in this focus issue of New Journal of Physics is intended as a snapshot of the cu…
Sperrarterien in der Aderhaut und am Sehnerveneintritt beim Hund.
1954
In der Aderhaut und am Sehnerveneintritt beim Hund werden Sperrarterien beschrieben, die mit zahlreichen Langsmuskelpolstern in der Intima ausgestattet sind und offenbar der Regulation der Aderhautdurchblutung dienen. Auch andere Besonderheiten am Gefassystem im Bereich des Sehnerveneintritts (Venenplexus, arteriovenose Anastomosen) konnten nachgewiesen werden. Weder bei der Katze, beim Kaninchen, Meerschweinchen oder Menschen kommen ahnliche Gefasregulationseinrichtungen vor.
Acoustic phonons for coherent photon control in semiconductor structures
2007
We present a novel concept for acousto-optical modulation in waveguide (WG) structures using coherent phonons in the form of surface acoustic waves (SAWs). Here, a SAW impinging perpendicular to a waveguide structure induces a change in phase of the light propagating through it, which is translated into a transmission intensity modulation by using the WG as an arm of a Mach-Zehnder interferometer (MZI). We show that the modulation becomes strongly enhanced if the SAW induces phase changes of opposite sign in the MZI arms. Very compact modulators with an interaction length between the optical and acoustic waves of approx. 15 µm have been fabricated using focusing acoustic transducers to gene…
Parallel phase-shifting digital holography based on the fractional Talbot effect
2010
A method for recording on-axis single-shot digital holograms based on the self-imaging phenomenon is reported. A simple binary two-dimensional periodic amplitude is used to codify the reference beam in a Mach-Zehnder interferometer, generating a periodic three-step phase distribution with uniform irradiance over the sensor plane by fractional Talbot effect. An image sensor records only one shot of the interference between the light field scattered by the object and the codified parallel reference beam. Images of the object are digitally reconstructed from the digital hologram through the numerical evaluation of the Fresnel diffraction integral. This scheme provides an efficient way to perfo…