Search results for "Sensor"

showing 10 items of 4594 documents

Electrophysiological patterns of oropharyngeal swallowing in multiple sclerosis.

2012

Abstract Objective We performed an electrophysiological study of swallowing (EPSS) in multiple sclerosis (MS) to describe oropharyngeal swallowing abnormalities and to analyze their correlations with dysphagia and with overall neurological impairment. Methods Neurological examinations were quantified using the Kurtzke Functional Systems and the Expanded Disability Status Scale (EDSS). Dysphagia was evaluated using the Dysphagia in Multiple Sclerosis (DYMUS) questionnaire, while fiberoptic endoscopic evaluation of swallowing (FEES) was used to establish the degree of aspiration and penetration, graded using the penetration–aspiration scale (PAS). The EPSS measured the duration of suprahyoid/…

AdultMalemedicine.medical_specialtyMultiple SclerosisOropharynxElectromyographyBladder Sphincter DysfunctionDysphagia swallowing electromiography multiple sclerosisSwallowingPhysiology (medical)otorhinolaryngologic diseasesmedicineHumansAgedExpanded Disability Status Scalemedicine.diagnostic_testbusiness.industryElectromyographyMultiple sclerosisMiddle Agedmedicine.diseaseDysphagiaSensory SystemsPathophysiologySurgeryDeglutitionNeurologyAnesthesiaFemaleNeurology (clinical)medicine.symptomAbnormalitybusinessDeglutition DisordersClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
researchProduct

Paradoxical heat sensation in patients with multiple sclerosis

1996

Temperature thresholds were determined in 16 patients with probable or definite multiple sclerosis, in six patients with possible but unconfirmed multiple sclerosis and in 34 healthy subjects, using the method of limits and the thermal sensory limen (TSL) of the MarStock technique. A significant proportion of the patients had thresholds outside the 2.5 SD range for normal subjects, both for warmth detection threshold and TSL. In addition, 10 patients with probable or definite multiple sclerosis and one patient with possible multiple sclerosis reported a paradoxical heat sensation, i.e. a sensation of warmth elicited by a cold stimulus. This illusion was almost exclusively observed with the …

AdultMalemedicine.medical_specialtyMultiple Sclerosismedicine.medical_treatmentCentral nervous systemSensory systemAudiologyStimulus (physiology)Central nervous system diseaseSensationHumansMedicineThermal grill illusionbusiness.industryMultiple sclerosisMiddle Agedmedicine.diseasemedicine.anatomical_structureSensory ThresholdsNerve blockFemaleNeurology (clinical)businessNeuroscienceBody Temperature RegulationDemyelinating DiseasesBrain
researchProduct

Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

2008

To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…

AdultMalemedicine.medical_specialtyMydriaticsMaterials scienceBiometrygenetic structuresLightAnterior ChamberDiagnostic Techniques OphthalmologicalEyeCorneaLens thicknessOphthalmologyLens CrystallinemedicineHumansBody Weights and Measuresbusiness.industryUltrasoundReproducibility of ResultsCycloplegiaPupileye diseasesSensory SystemsSurgeryOphthalmologyInterferometrySoundPartial coherence interferometrySurgeryFemalesense organsmedicine.symptombusinessPartial coherenceJournal of cataract and refractive surgery
researchProduct

Hypoesthesia in generalised anxiety disorder and major depression disorder

2018

Objective: The determination of soft signs can be a conducive practice to understand the differential etiology between depression and anxiety. This study aims at examining malleolar hypoesthesia ro...

AdultMalemedicine.medical_specialtyNeurological soft signsDiagnosis Differential03 medical and health sciences0302 clinical medicineGeneralised anxiety disordermedicineHumansPsychiatryDepression (differential diagnoses)Depressive Disorder Majorbusiness.industryfungifood and beveragesHypoesthesiaMiddle AgedAnxiety Disorders030227 psychiatryPsychiatry and Mental healthTouchSomatosensory DisordersEtiologyAnxietyFemaleAnklemedicine.symptombusiness030217 neurology & neurosurgeryInternational Journal of Psychiatry in Clinical Practice
researchProduct

Meibomian glands structure in daily disposable soft contact lens wearers: a one‐year follow‐up study

2020

Purpose To assess the impact of daily disposable soft contact lenses on meibomian gland morphology over a period of 12 months. Methods Forty-one subjects (33 experienced and 8 neophytes) were fitted with either silicone-hydrogel or hydrogel daily contact lenses. The study protocol included four visits: baseline, day-2 for contact lens fit and follow-up measurements, as well as after 6 and 12 months of lens wear. Non-contact infrared meibography images were acquired with Keratograph 5M topographer (www.oculus.de) and analysed with an automated method, which objectively estimates the area of gland atrophy, gland length and width, number of glands and gland irregularity. Protocol at follow-up …

AdultMalemedicine.medical_specialtyOne year follow upMeibomian glandlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineAtrophylawOphthalmologyHumansMedicineOcular Surface Disease IndexProspective StudiesVision Ocularbusiness.industryOsmolar ConcentrationMeibomian GlandsContact Lenses Hydrophilicmedicine.diseaseeye diseasesSensory SystemsLens (optics)Contact lensOphthalmologymedicine.anatomical_structurePatient SatisfactionTears030221 ophthalmology & optometryFemaleDaily disposablesense organsbusinessEarly phase030217 neurology & neurosurgeryFollow-Up StudiesOptometryOphthalmic and Physiological Optics
researchProduct

Assessment of induced corneal hypoxia in diabetic patients

2002

Comparative Study Address correspondence and reprint requests to Dr. C. Creuzot-Garcher, Service d'Ophtalmologie, CHU, Hopital Général, 3 Rue du Faubourg Raines, BP 1519, 21033 Dijon, France. E-mail: Catherine.creuzot-garcher@chu-dijon.fr; To assess the control of corneal hydration in patients with diabetes during a contact lens-induced hypoxia. Corneal stress was induced in 15 patients with diabetes and 23 healthy patients by having them wear contact lenses for 2 hours. Pachymetries were measured and corneal parameters (percentage recovery per hour [PRPH], time for deswelling [T99%] and induced swelling [IS]) were calculated. In the mean time, tears were collected to assess the activity of…

AdultMalemedicine.medical_specialtyPathologyCell CountCorneachemistry.chemical_compoundStress PhysiologicalOphthalmologyLactate dehydrogenaseDiabetes mellitusHumansMedicineIn patient[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansHypoxiaAged[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologyL-Lactate Dehydrogenasebusiness.industryCorneal EdemaEndothelium CornealMiddle AgedHypoxia (medical)Contact Lenses Hydrophilicmedicine.diseaseeye diseasesOphthalmologyDiabetes Mellitus Type 1Diabetes Mellitus Type 2chemistry[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory OrgansTearsTearsFemaleCorneal hypoxiasense organsmedicine.symptomSwellingbusinessAnaerobic exercise[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Afferent contribution to locomotor muscle activity during unconstrained overground human walking:an analysis of triceps surae muscle fascicles

2010

Plantar flexor series elasticity can be used to dissociate muscle–fascicle and muscle–tendon behavior and thus afferent feedback during human walking. We used electromyography (EMG) and high-speed ultrasonography concomitantly to monitor muscle activity and muscle fascicle behavior in 19 healthy volunteers as they walked across a platform. On random trials, the platform was dropped (8 cm, 0.9 g acceleration) or held at a small inclination (up to ±3° in the parasagittal plane) with respect to level ground. Dropping the platform in the mid and late phases of stance produced a depression in the soleus muscle activity with an onset latency of about 50 ms. The reduction in ground reaction force…

AdultMalemedicine.medical_specialtyPhysiologyPostureSensory systemWalkingElectromyographyAchilles TendonPlantar flexionTendonsYoung AdultPhysical medicine and rehabilitationTriceps surae muscleAfferentHumansMedicineNeurons AfferentMuscle activityMuscle SkeletalUltrasonographyLegmedicine.diagnostic_testElectromyographybusiness.industryGeneral NeuroscienceBiomechanicsMotor controlmusculoskeletal systemBiomechanical PhenomenaData Interpretation StatisticalFemalebusinessLocomotionMuscle Contraction
researchProduct

Motor learning without doing: trial-by-trial improvement in motor performance during mental training.

2010

Although there is converging experimental and clinical evidences suggesting that mental training with motor imagery can improve motor performance, it is unclear how humans can learn movements through mental training despite the lack of sensory feedback from the body and the environment. In a first experiment, we measured the trial-by-trial decrease in durations of executed movements (physical training group) and mentally simulated movements (motor-imagery training group), by means of training on a multiple-target arm-pointing task requiring high accuracy and speed. Movement durations were significantly lower in posttest compared with pretest after both physical and motor-imagery training. …

AdultMalemedicine.medical_specialtyPhysiologyeducationSensory systemDevelopmental psychologyTask (project management)Young AdultPhysical medicine and rehabilitationMotor imageryMental practiceFeedback SensorymedicineHumansLearningMovement (music)General NeuroscienceTraining (meteorology)Biomechanical PhenomenaDuration (music)Practice PsychologicalImaginationFemalePsychologyMotor learningPsychomotor PerformanceJournal of neurophysiology
researchProduct

Prevalence and risk factors of diabetic retinopathy in adult and elderly subjects. The Casteldaccia Eye Study

2003

PURPOSE: To investigate the prevalence and risk factors of diabetic retinopathy in subjects aged 40 years or older living in Casteldaccia, Sicily. METHODS: A population-based survey was performed on 1,588 subjects randomly enrolled among people aged 40 years or older. A total of 1,068 persons could be examined and in 1,019 the fundus of the eye was adequately observed (64.2% of the enrolled population). Diabetic retinopathy was diagnosed by ophthalmoscopy and fundus photographs; fluorescein angiography was performed in 91% of retinopathic subjects. In addition, a case-control study was carried out in order to demonstrate the association of diabetic retinopathy with a number of variables. RE…

AdultMalemedicine.medical_specialtyPopulationFundus (eye)OphthalmoscopyCellular and Molecular NeuroscienceAge DistributionRisk FactorsInternal medicineDiabetes mellitusPrevalenceHumansMedicineSex DistributionRisk factoreducationSicilyAgededucation.field_of_studyDiabetic Retinopathymedicine.diagnostic_testbusiness.industryDiabetic Retinopathy Fluorescein Angiography Proliferative Diabetic Retinopathy Fundus Photograph Antidiabetic TreatmentCase-control studyDiabetic retinopathyMiddle Agedmedicine.diseaseFluorescein angiographyHealth SurveysSensory SystemsSurgeryOphthalmologyCase-Control StudiesFemalebusiness
researchProduct

Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.

2013

Purpose To evaluate the efficacy, predictability, safety, and stability of a new-model posterior chamber Implantable Collamer Lens phakic intraocular lens (pIOL) (V4c Visian) to correct myopia. Setting Private practice, Oviedo, Spain. Design Case series. Methods This study enrolled patients who had implantation of a new pIOL design with a central hole for more natural aqueous flow, eliminating the need for neodymium:YAG iridotomy or peripheral iridectomy. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refractive error, intraocular pressure (IOP), endothelial cell count, central vault, and adverse events were evaluated 6 months postoperatively. Results The study enroll…

AdultMalemedicine.medical_specialtyRefractive errorIntraocular pressurePhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityCell CountPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineMyopiaHumansProspective StudiesProspective cohort studyDioptreIntraocular PressureAqueous flowbusiness.industryEndothelium CornealCorneal Endothelial Cell Lossmedicine.diseaseRefractive Errorseye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomePrivate practiceIridectomySurgeryFemalesense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct