Search results for "Sensor"
showing 10 items of 4594 documents
Performance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability
2008
Aim: The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient’s age on the instrument performance are tested with a series of experiments. Methods: First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error −1.34 (2.72) D) were examined with the C-Quant straylightmeter, taking 10 consecutive readings. Five subjects were also examined on five consecutive days to assess reproducibility. Additionally, repeated measures of straylight from 84 subjects of ages ranging from 19 to 86 years (mean (SD): 42.4 (24.0) years) were retrospectively analysed to assess the …
Association of low birth weight with myopic refractive error and lower visual acuity in adulthood: results from the population-based Gutenberg Health…
2017
PurposeLow birth weight (BW) is linked to impaired organ development in childhood, including altered ocular morphological and functional development. The aim of this study was to evaluate whether low BW has long-term effects on visual acuity and refraction in adulthood.MethodsThe Gutenberg Health Study is a population-based, observational cohort study in Germany, including 15 010 participants aged between 35 and 74 years. These participants were divided into three different BW groups (low: <2500 g; normal: between 2500 and 4000 g; and high: >4000 g). Best-corrected visual acuity and objective refraction were examined. We used multivariable linear regression models with adjustment for …
Prevalence of myopic maculopathy in the German population: results from the Gutenberg health study.
2019
AimsTo determine the prevalence of myopic maculopathy in the general population in Germany and to analyse potential associations with ocular and systemic factors.DesignThe Gutenberg Health Study is a population-based study, including 15 010 participants aged 35–74 years.MethodsMyopic maculopathy was graded in phakic eyes with spherical equivalent ≤−6 D by assessing fundus photographs according to a recent international photographic classification system (META-PM). 801 eyes of 519 participants (mean age 51.0±0.77 years) met the conditions and had gradable fundus photographs. Age-specific prevalence estimates were computed. Multivariable logistic regression analysis was used to assess associa…
Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).
2014
Objective To study the distribution of refractive errors among adults of European descent. Design Population-based eye study in Germany with15 010 participants aged 35–74 years. Methods The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia +0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. Results 13 959 subjects were eligible. Refractive errors ranged from −21.5 to…
Analysis of thiamine transporter genes in sporadic beriberi
2014
Abstract Objective Thiamine or vitamin B 1 deficiency diminishes thiamine-dependent enzymatic activity, alters mitochondrial function, impairs oxidative metabolism, and causes selective neuronal death. We analyzed for the first time, the role of all known mutations within three specific thiamine carrier genes, SLC19 A2, SLC19 A3 , and SLC25 A19 , in a patient with atrophic beriberi, a multiorgan nutritional disease caused by thiamine deficiency. Methods A 44-year-old male alcoholic patient from Morocco developed massive bilateral leg edema, a subacute sensorimotor neuropathy, and incontinence. Despite normal vitamin B 1 serum levels, his clinical picture was rapidly reverted by high-dose in…
First experiences with a high-resolution ultrasonic scanner in the diagnosis of malignant melanomas
1983
The use of high-resolution ultrasonic instruments with transducer frequencies above 8 MHz makes it possible to visualize malignant melanomas of a thickness of more than 0.7 mm. While the sonolucent structure has not permitted the dignity of a lesion to be judged to date, it is easy to determine the maximal tumor thickness as well as infiltration of the subcutis. Thus "low-risk" and "high-risk" melanomas may be differentiated preoperatively according to these parameters. The results are of great use for the operator to plan the extent of his intervention, as well as to select patients for prophylactic regional lymphonodectomy.
A breathing-retraining procedure in treatment of sleep-onset insomnia: theoretical basis and experimental findings.
1995
Increase in CO2 has a sedative effect upon the central nervous system, and the beginning of sleep coincides with modifications in breathing, decrease in ventilation, and in pCO2 increase. In this paper is described a technique of breathing that is useful in producing drowsiness in a very short time. 46 insomniacs were randomly allocated to either a treatment or control condition. In the former, patients were trained in the breathing process. The control group was taught no breathing process. Latencies to sleep for the insomniacs confirmed that the breathing process was useful in producing drowsiness. Theoretical bases are discussed.
Detached and distracted: ERP correlates of altered attentional function in depersonalisation.
2018
Abstract Depersonalisation (DP) is a psychological condition marked by feelings of disembodiment. In everyday life, it is frequently associated with concentration problems. The present study used visual event-related potentials (ERPs) in a Posner-type spatial cueing task with valid, invalid and spatially neutral cues to delineate the potential neurophysiological correlates of these concentration problems. Altered attentional functioning at early, sensory stages was found in DP patients but not in anxiety- and depression-matched psychosomatic patients without DP. Specifically, DP was associated with decreased suppression of stimuli at unattended locations, shown as absent processing costs fo…
Hemisensory disturbances in patients with complex regional pain syndrome.
2018
Sensory disturbances often spread beyond the site of injury in complex regional pain syndrome (CRPS) but whether this applies equally to CRPS I and II, or changes across the course of the disease, is unknown. Establishing this is important, because different symptom profiles in CRPS I and II, or in acute vs chronic CRPS, might infer different pathophysiology and treatment approaches. To explore these questions, sensory disturbances were assessed in the limbs and forehead of 71 patients with CRPS I and 33 patients with CRPS II. Pain had persisted up to 12 months in 32 patients, for 13 to 36 months in 29 patients, and for longer than this in 43 patients. Patients with CRPS I were more likely …
Evoked potential study in facio-scapulo-humeral muscular dystrophy.
1997
Nerve conduction velocities (NCVs), somatosensory (SEPs) and auditory evoked potentials (BAEPs) were recorded in 9 patients with facio-scapulo-humeral dystrophy (FSHD) and in 20 age-matched controls. In FSHD patients a significant increase of the nerve distal sensory latencies and of the absolute SEP latencies revealed a subclinical involvement of the afferent sensory pathways, as well as the abnormal slowing of the later components of the BAEPs, pointed to a central auditory dysfunction. Moreover all patients underwent brain MRI that showed the presence of white matter hyperintense lesions in 4 of them (44%). No correlations were found between individual or total number of SEP and BAEP abn…