Search results for "Sensor"
showing 10 items of 4594 documents
Precursors of the evoked K-complex in event-related brain potentials in stage 2 sleep.
1997
The aim of the study was to examine precursors of the evoked K-complex as manifested in event-related brain potentials (ERPs) during stage 2 sleep. ERPs to infrequent deviant tones of 1100 and 2000 Hz and immediately preceding frequent standard tones of 1000 Hz were compared between trials containing and trials not containing a K-complex (KC trials, NO KC trials, respectively) to the deviant tones. The N350 wave to the deviant tones was markedly larger during the KC than during the NO KC trials. Also the P210 wave to the 2000 Hz deviant tone showed the same phenomenon. No definite evidence was found for the mismatch negativity-like deflection during the KC trials. ERPs to the standard tones…
DPOAE‐Grams in Patients with Acute Tonal Tinnitus
2005
To investigate cochlear outer hair cell function in patients with acute tonal tinnitus and normal or near-normal hearing threshold.Prospective controlled study in an academic tertiary health center. Distortion products of otoacoustic emissions (DPOAE)-grams of 32 ears with acute tonal tinnitus and normal hearing or minimal hearing loss were compared with those of 17 healthy nontinnitus ears.Tinnitus ears exhibited relatively increased amplitudes of DPOAE at high frequencies (4-6.3 kHz) when compared with the group of healthy ears and relatively decreased DPOAE amplitudes at middle frequencies (1650-2400 Hz). Statistically significant ( P0.01) increased mean values of DPOAE amplitudes were o…
Are different kinds of acoustic features processed differently for speech and non-speech sounds?
2001
This study examined how changes in different types of acoustic features are processed in the brain for both speech and non-speech sounds. Event-related potentials (ERPs) were recorded in native Finnish speakers presented with sequences of repetitive vowels (/e/) or complex harmonical tones interspersed with infrequent changes in duration, frequency and either a vowel change (/o/ for vowel sequences) or a double deviant (frequency+duration change for tone sequences). The stimuli were presented monaurally in separate blocks to either the left or right ear. The results showed that speech stimuli were more efficiently processed than harmonical tones as reflected by an enhanced mismatch negativi…
Single-Sided Deafness: Impact of Cochlear Implantation on Speech Perception in Complex Noise and on Auditory Localization Accuracy.
2017
Objective To assess auditory localization accuracy and speech reception threshold (SRT) in complex noise conditions in adult patients with acquired single-sided deafness, after intervention with a cochlear implant (CI) in the deaf ear. Study design Nonrandomized, open, prospective patient series. Setting Tertiary referral university hospital. Patients Eleven patients with late-onset single-sided deafness (SSD) and normal hearing in the unaffected ear, who received a CI. All patients were experienced CI users. Intervention Unilateral cochlear implantation. Main outcome measures Speech perception was tested in a complex multitalker equivalent noise field consisting of multiple sound sources. …
CT-guided stereotactic biopsy aided by Doppler ultrasonic vascular monitoring
1992
The use of a 20 MHz pulsed Doppler technique during stereotactic brain tumour biopsies is described. By means of a miniaturized ultrasonic probe the tissue planned for biopsy was investigated for vessel signals. Out of 41 patients, with this technique a flow-pulse curve in front of the biopsy cannula was registered in 14 cases. In 9 cases one pulse curve was determined and in 5 cases two or more flow curves were found, indicating the presence of arterial vessels. The depth of the vessels signal could be localized and this area avoided for biopsy sampling. In a series of 41 stereotactic biopsies carried out in this way there was no intra-operative haemorrhage or postoperative haematoma.
The Effect of Color on the Use of Electronic Body Protectors in Taekwondo Matches
2016
This study investigated the relationship between the color protector and success in taekwondo combats in the qualification championships, when electronic body protectors were used. Moreover, it analyzed the confounding effect of a participant being a top-ranked athlete in the 2012 London Olympic Games, in a sample of 462 matches. Results from the entire sample showed a non-significant relationship between the combat outcome and the winner’s color electronic protector. At the level of the tournament, the results showed a significant relationship between wearing a red electronic protector and winning the combat in the Asian and the European qualification tournaments. For gender and weight ca…
[Clinical and radiological evolution of a group of untreated acoustic neuromas].
2013
Abstract Introduction The acoustic neuroma is a benign tumour that originates in the vestibular branch of the eighth cranial nerve. The main treatment is surgery, but many authors suggest that with elderly patients or in small neuromas we can opt for watchful waiting. Methods This was a retrospective study from 2007 to 2013 that included 27 patients diagnosed of acoustic neuroma that had not been treated due to the size of the tumour, age and comorbidities, or by patient choice. We evaluated overall condition, hearing thresholds, degree of canal paresis and central disorders. Results After 6 years of follow up, clinical manifestations of 18 patients remained unchanged, 5 patients underwent …
FUNCTIONAL EFFECT OF SHORT-TERM IMMOBILIZATION: KINEMATIC CHANGES AND RECOVERY ON REACHING-TO-GRASP
2012
Abstract Although previous investigations agree in showing significant cortical modifications related to short-term limb immobilization, little is known about the functional changes induced by non-use. To address this issue, we studied the kinematic effect of 10 h of hand immobilization. In order to prevent any movement, right handed healthy participants wore on their dominant hand a soft bandage. They were requested to perform the same reaching-to-grasping task immediately after immobilization, 1 day before (baseline 1) and in other two following days without non-use (baseline 2 and baseline 3). While no differences were found among baseline conditions, an increase of the total duration of…
Comparison of electromyographic pattern of sensory experts and untrained subjects during chewing of Mahon cheese
2002
Use of electromyography (EMG) to monitor mastication is a relatively new concept in assessing food physical and sensory properties. Although expert assessment of cheese characteristics is widely used, the effect of training in sensory analysis on mastication patterns, as assessed using EMG is not well known. Nine samples of the same Mahon cheese (60 days ripening) were given to 24 subjects (8 experts, 16 untrained) and EMG recorded for each chewing sequence. Three samples were tested in a single session by each subject, and three sessions carried out on different days. EMG was recorded from four masticatory muscles for each subject. From EMG records the following was extracted: number of ch…
The time course of temporal discrimination: An ERP study
2009
Objective: The question of how temporal information is processed by the brain is still a matter of debate. This study aimed to elucidate the brain electrical activity associated with a visual temporal discrimination task. Methods: For this purpose, 44 participants were required to compare pairs of sequentially presented time intervals: a fixed standard interval (1000 ms), and an equal-to-standard, longer (1200 ms) or shorter (800 ms) comparison interval. Behavioural data and event-related potentials (ERPs) were analyzed. Results: Long intervals were more rapidly identified than short intervals. The amplitude of the contingent negative variation (CNV) found at frontocentral sites before the …