Visually produced locomotion in an autokinetic setup.
1987
On individual ttials, 15 subjects stood G m before a minicomputer screen displaying a colon in a completely darkened room Subjects were aware that the light source wzs stationary. They were instructed to fixate the colon and to perform nonlocomotive jogging in place for 2 min. and continuously to report their sensations. Room lights were turned on after 30 sec., and subjects' deviations from their starting places were measured. All subjects had moved toward the light source (M = 4.42 m, SD = .43) although they were convinced that they had not moved. Instead, they had reported either the light source approached them or the light source became larger and/or more intense. On a second trial, su…
Posterior chamber phakic intraocular lenses after penetrating keratoplasty.
2009
Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …
Yellow (577 nm) micropulse laser versus half-dose verteporfin photodynamic therapy in eyes with chronic central serous chorioretinopathy: results of …
2018
PurposeTo compare the functional and anatomical outcomes of eyes with chronic central serous chorioretinopathy treated with yellow micropulse (MP) laser versus half-dose verteporfin photodynamic therapy (PDT).MethodsThis is a multicentre, retrospective comparative study of 92 eyes treated with yellow MP laser (duty cycle of 5%, zero spacing between spots, spot size varied from 100 to 200 µm, power varied from 320 to 660 mW, and the pulse burst duration was 200 ms) and 67 eyes treated with PDT (half-dose verteporfin (3 mg/m2) infused over 10 min), followed by laser activation for 83 s. Spot sizes varied from 400 to 2000 µm.ResultsIn the MP group, at 12 months of follow-up, the mean best corr…
P26-S Left and right motor cortical excitability and relationship to motor functions in healthy adolescents
2019
Background The interhemispheric difference in cortical excitability and its relationship to motor functions is unclear. Aim We examined the relationship between handedness, left and right motor cortex excitability and fine and gross motor functions in adolescence. Methods 28 healthy adolescents (age 16–19 years, 19 girls) were studied. Handedness was determined by the Waterloo Handedness Questionnaire. Motor threshold (MT) of the abductor pollicis brevis was measured on both hemispheres using biphasic stimulation, and on the left hemisphere also with monophasic stimulation. Box and block test (BBT) was used for manual dexterity, line run and standing long jump for gross motor tasks. Spearma…
P 61. Is high frequency rTMS a new tool in remediating dyslexia?
2013
Introduction Evidence from functional neuroimaging has reported hypoactivation of the left parieto-temporal regions in children and adults with dyslexia when they engage in reading-related tasks (Shaywitz et al., 2002; Richlan et al., 2011). Studies on the remediation of dyslexia have consistently found that remedial treatment improves reading ability and increases activation in critical brain areas (Temple et al., 2003; Hoeft et al., 2011). Objectives We wanted to determine whether high frequency repetitive trancranial magnetic stimulation (hf-rTMS) over areas that are underactive in dyslexics during reading, such as the left superior temporal gyrus (STG) and the left inferior parietal lob…
Closed foldable capsular rings
2004
A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.
Solvent for removing silicone oil from intraocular lenses: experimental study comparing various biomaterials.
2000
Abstract Purpose To evaluate the effectiveness of a perfluorocarbon—perfluorohexyloctane (PFHO)—in removing silicone oil from different intraocular lenses (IOLs) and determine whether any removal technique enhances the removal of silicone oil. Methods Six IOL materials were analyzed: standard poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, AcrySof, 2 polyHEMAs with different water contents, and a second-generation SLM-2 silicone. One or 2 μL of a highly viscous silicone oil (5700 cs) was applied to the center of each IOL optic. Perfluorohexyloctane (2 mL) was then used to remove the silicone oil by 1 of 3 techniques: immersion of the IOL in PFHO; irrigation of the sil…
Compression forces of haptics of selected posterior chamber lenses
1997
Abstract Purpose: To compare the compressive forces of the haptics of different intraocular lens (IOL) models and analyze the observed differences. Setting: Central Hospital of Central Finland and University of Jyvaskyla, Jyvaskyla, Finland. Methods: The haptics of 28 IOL models were compressed to a diameter of 9.0 mm. The compression forces were measured at 0.5 mm intervals. The conclusions were verified by numerical simulations of mechanical models of the lenses. Results: The measured forces varied between 100 and 601 mg at a diameter of 11.0 mm, 206 and 1057 mg at a diameter of 10.0 mm, and 315 and 2094 mg at a diameter of 9.0 mm. The slopes of the force curves of the three-piece lenses …
Compression forces of haptics of freely rotating posterior chamber intraocular lenses.
1998
Abstract Purpose: To measure the compressive forces of the haptics of 28 intraocular lens (IOL) models for different modes of compression and compare the results of two types of measurements. Setting: Department of Ophthalmology, Central Hospital of Central Finland, Jyvaskyla, Finland. Methods: The haptics of 28 types of IOLs were compressed to a diameter of 9.0 mm between curved anvils. The compression forces in the plane of compression (i.e., in the plane of the optics) were measured at 0.5 mm intervals. During compression, the optics and the haptics were free to rotate with respect to the anvils. The results were compared with those of earlier measurements in which the optics were held f…
A rapid method for measuring intraocular lens power in vitro with a focimeter.
2015
In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.