Psychophysical and electrofunctional contrast sensitivity in cataractous patients treated with bendazac-lysine salt
1990
The clinical progression of the cataract may be influenced by drugs which reduce the denaturation of lens proteins. One of the most promising drugs is the bendazac-lysine salt. The drug was used in a double-blind study of a group of patients with initial cortical cataract in order to evaluate the changes in visual acuity and contrast sensitivity by means of a psychophysical and an electrophysiological method. After 6 months of treatment with bendazac the mean values of visual acuity showed a statistically significant increase in respect to baseline values, as well as an improvement of the threshold of contrast for most spatial frequencies. In the eyes treated with placebo there was no stati…
Latanoprost-induced iris darkening: a morphometric study of human peripheral iridectomies.
2003
Abstract Purpose. This microscopic study was undertaken to compare the melanocytes of peripheral iridectomy specimens from two eyes that had latanoprost-induced iris darkening (LIID) with iridectomies taken from the fellow untreated eyes. Methods. The two patients in this study were the ones who underwent LIID in the latanoprost treated eye from a series of 17 patients requiring bilateral trabeculectomy. The first trabeculectomy procedure provided a control peripheral iridectomy for each patient, whereas the second eye was treated with once daily 50 μg ml−1 latanoprost drops for 6 months. The four peripheral iridectomy specimens from the two LIID patients were subjected to quantitative morp…
Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.
2003
Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…
Oxidative tissue damage after phacoemulsification: influence of ophthalmic viscosurgical devices.
2003
To quantify the oxidative tissue damage after phacoemulsification, correlate the damage to the energy applied, and investigate the influence of ophthalmic viscosurgical devices (OVDs).Department of Ophthalmology, University of Mainz, Mainz, Germany.The study comprised 130 eyes operated on by 1 surgeon using the same phacoemulsification machine. Some eyes received an OVD before phacoemulsification and some did not. Energy values were expressed as phaco time; that is, ultrasound (US) time (seconds) after conversion to 100% phaco power. Patients were grouped as follows: Group 1, phaco time less than 20 seconds and no OVD; Group 2, phaco time 20 to 40 seconds and no OVD; Group 3, phaco time mor…
Spring constants of capsular tension rings.
2004
Purpose To determine the spring constants of several types of capsular tension rings (CTRs). Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Fourteen models of CTRs provided by 9 companies were tested; all were 11.0 mm in diameter. The CTRs were positioned in a special retainer of a material-testing machine and compressed at a constant speed of 10.0 mm per minute. The distance and force values were recorded, and each CTR model was tested 3 times using a new specimen each time. The resulting measurements were used to calculate a mean spring constant for each CTR model. Results All tested CTRs showed linear proportionality between force and compress…
Healon5 viscoadaptive formulation: Comparison to Healon and Healon GV
2001
Abstract Purpose To compare the rheological characteristics of a viscoadaptive viscoelastic formulation with those of 2 standard ophthalmic viscosurgical devices (OVDs). Setting Department of Ophthalmology, Johannes Gutenberg-University, and Max Planck-Institute for Polymer Research, Mainz, Germany. Methods An independent comparative study of 3 OVDs of sodium hyaluronate (Healon®, Healon GV®, and Healon®5) was performed using the Advanced Rheometric Expansion System to analyze rheologic behavior (eg, dynamic frequency dependence of the complex viscosity) as well as rheological parameters (eg, viscosity at zero shear rate, pseudoplasticity, relaxation time, elastic and viscous modulus). Resu…
P13. Compensation processes for central vestibular dysfunction in patients with acute medullary infarctions (FDG-PET study)
2007
Deviance detection in sound frequency in simple and complex sounds in urethane-anesthetized rats
2019
Mismatch negativity (MMN), which is an electrophysiological response demonstrated in humans and animals, reflects memory-based deviance detection in a series of sounds. However, only a few studies on rodents have used control conditions that were sufficient in eliminating confounding factors that could also explain differential responses to deviant sounds. Furthermore, it is unclear if change detection occurs similarly for sinusoidal and complex sounds. In this study, we investigated frequency change detection in urethane-anesthetized rats by recording local-field potentials from the dura above the auditory cortex. We studied change detection in sinusoidal and complex sounds in a series of …
Evaluation of movement and brain activity
2021
Clinical neurophysiology studies can contribute important information about the physiology of human movement and the pathophysiology and diagnosis of different movement disorders. Some techniques can be accomplished in a routine clinical neurophysiology laboratory and others require some special equipment. This review, initiating a series of articles on this topic, focuses on the methods and techniques. The methods reviewed include EMG, EEG, MEG, evoked potentials, coherence, accelerometry, coherence, posturography (balance), gait, and sleep studies. Functional MRI (fMRI) is also reviewed as a physiological method that can be used independently or together with other methods. A few applicat…