Search results for "Sensory Systems"
showing 10 items of 793 documents
Evolving European guidance on the medical management of neovascular age related macular degeneration
2006
BACKGROUND: Until recently, only two options were available for the treatment of choroidal neovascularisation (CNV) associated with age related macular degeneration (AMD)-thermal laser photocoagulation and photodynamic therapy with verteporfin (PDT-V). However, new treatments for CNV are in development, and data from phase III clinical trials of some of these pharmacological interventions are now available. In light of these new data, expert guidance is required to enable retina specialists with expertise in the management of AMD to select and use the most appropriate therapies for the treatment of neovascular AMD. METHODS: Consensus from a round table of European retina specialists was obt…
Postoperative Lens Position Preoperatively Determined by Scheimpflug Photography
1999
The position of the artificial lens has an important influence on refractive power calculation. We compared the position of the crystalline lens with that of the artificial lens after cataract surgery by means of Scheimpflug photography. A difference in position of approximately 0.8 mm in the anterior direction could be determined.
Clinical and genetic update of corneal dystrophies.
2019
The International Committee for Classification of Corneal Dystrophies (IC3D) distinguishes between 22 distinct forms of corneal dystrophy which are predominantly autosomal dominant, although autosomal recessive and X-chromosomal dominant patterns do exist. Before any genetic examination, there should be documentation of a detailed corneal exam of as many affected and unaffected family members as possible, because detailed phenotypic description is essential for accurate diagnosis. Corneal documentation should be performed in direct and indirect illumination at the slit lamp with the pharmacologically dilated pupil. For the majority of the corneal dystrophies, a phenotype-genotype correlatio…
Brimonidine versus dapiprazole: Influence on pupil size at various illumination levels.
2005
To evaluate the influence of dapiprazole versus brimonidine on pupil size at various illumination levels.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In randomized prospective study, 19 healthy volunteers received 2 ophthalmic solutions, dapiprazole and brimonidine, 1 in each eye, for intraindividual comparison. Before and after application, pupil diameter was measured using an infrared binocular pupillometer at 3 illumination levels (0.03, 0.82, and 6.4 lux).Only slight pupil dilation was observed under scotopic conditions after application of both agents. After 20 minutes, the median reduction in pupil width was 1.4 mm for brimonidine and 0.9 mm for dapiprazo…
Spotlight on fundus autofluorescence.
2018
Fundus autofluorescence (FAF) imaging is based on the fluorescence from ocular endogenous fluorophores located in the retinal pigment epithelium and choroid, mainly lipofuscin and melanin. It is a noninvasive technique that provides information about the spatial distribution of lipofuscin/melanin and retinal pigment epithelium health status. An overview about the fluorophores responsible for FAF imaging and the usefulness of FAF imaging in the noninvasive assessment and monitoring of retinal diseases, such as age-related macular degeneration, diabetic retinopathy, diabetic macular edema, central serous chorioretinopthy, retinitis pigmentosa and retinal dystrophies, are discussed in this rev…
Effects of Superficial Keratectomy in Peripheral Hypertrophic Subepithelial Corneal Opacification on Front and Back Corneal Astigmatism
2020
To evaluate changes of anterior and posterior corneal astigmatism after superficial keratectomy in peripheral hypertrophic subepithelial corneal opacification (PHSCO). Patients with PHSCO, who had ...
Vacuoles in the Acrysof<sup>TM</sup> Intraocular Lens as Factor of the Presence of Serum in Aqueous Humor
2001
<i>Objective:</i> Acrysof™ (Alcon) foldable lenses (IOLs) have been shown to be highly biocompatible and exhibit a low incidence of posterior capsular opacification. However, minute vacuoles or ‘glistenings’ have been observed in some Acrysof IOLs. The clinical relevance of vacuole formation is presently unclear. To help clarify the influence of factors present under in vivo conditions on vacuole formation, the present experimental study examines the influence of aqueous humor components on the occurrence of vacuoles in Acrysof IOLs. <i>Methods:</i> A total of 12 sterile Acrysof IOLs (Alcon, MA60BM) were incubated at body temperature (37°C) for 3 or 6 months in anter…
Role of the tear film in the optical quality of the human eye.
2007
This paper reviews recent studies of the role of the tear film in the optical quality of the eye. Recent investigations focus on the dynamics of the tear film after a blink and its important role in the optical quality of the eye. The results in this review were used in an attempt to understand the optical and visual impact of tear-film breakup in normal eyes and dry eyes. It was noted that patients with dry-eye syndrome have large optical aberrations compared with those in normal eyes, which may be the cause of blurry vision associated with the syndrome. In addition, instillation of artificial tears reduces optical aberrations and thus improves the optical quality of vision in these patien…
Binocular Vision in Patients with Multiple Sclerosis.
2021
Amparo Gil-Casas,1,2 David P Pi&ntilde;ero-Llorens,2 Ainhoa Molina-Martin2 1Cl&iacute;nica Optom&eacute;trica, Fundaci&oacute; Llu&iacute;s Alcany&iacute;s, University of Valencia, Valencia, Spain; 2Optics and Visual Perception Group (GOPV), Department of Optics, Pharmacology, and Anatomy, University of Alicante, Alicante, SpainCorrespondence: Ainhoa Molina-MartinDepartment of Optics, Pharmacology, and Anatomy, University of Alicante, Carretera San Vicente del Raspeig, San Vicente del Raspeig, 03690, Alicante, SpainTel +34 965 903-400Email ainhoa.molina@ua.esPurpose: Oculomotor disorders have been reported in multiple sclerosis (MS) in up to 80% of cases. There have …
2017
The mere presence of a depiction of eyes can elicit a sense of being watched in the perceiver. To this date, the factors affecting the intensity of this sense of being watched, however, have not been investigated. In the present experiment, we tested the impact of two potentially relevant variables: arousal (manipulated using specific musical pieces) and duration of the perceptual episode (manipulated using presentation times of 200 ms and 10 s, respectively). We asked participants to report how intensely they felt being watched while we exposed them to various observation cues ranging from human eyes to surveillance cameras. We found that, on average, reported intensities were higher if pa…