Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up

2014

Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyCiliary sulcusgenetic structuresOne year follow upPolymersVisual AcuityBiocompatible MaterialsPhakic intraocular lensYoung AdultLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesIntraoperative ComplicationsProspective cohort studyDioptreImplantable collamer lensEfficacy indexbusiness.industryCiliary Bodyeye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyFemaleSurgeryCollagenbusinessJournal of Cataract and Refractive Surgery
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Modulatory effects of low- and high-frequency repetitive transcranial magnetic stimulation on visual cortex of healthy subjects undergoing light depr…

2005

The aim of the present study was to explore further the effects of light deprivation (LD) on visual cortex excitability. Healthy subjects reporting reliable induction of phosphenes by occipital transcranial magnetic stimulation (TMS) underwent 60 min of complete LD. Phosphene threshold (PT) was measured before (T0), after 45 min (T1) and 60 min (T2) of LD, and then every 10 min after light re-exposure until recovery to T0 values. Repetitive TMS (rTMS) (at 1 or 10 Hz) was applied in separate sessions during the last 15 min of LD. PTs significantly decreased after 45 min of LD. rTMS differentially modified the effects of 60 min LD on PTs depending on stimulation frequency. One hertz rTMS did …

AdultMalePhosphenesNeural Inhibition/physiology Phosphenes/physiology Photic Stimulation Sensory Deprivation/physiology Transcranial Magnetic Stimulation Visual Cortex/physiologyNeural InhibitionMiddle AgedTranscranial Magnetic StimulationElectric StimulationIntegrative PhysiologyHumansFemaleSensory DeprivationPhotic StimulationVisual CortexThe Journal of physiology
researchProduct

Feasibility and reproducibility of electroencephalography-based corticokinematic coherence

2020

Corticokinematic coherence (CKC) is the phase coupling between limb kinematics and cortical neurophysiological signals, reflecting cortical processing of proprioceptive afference, and it is reproducible when estimated with magnetoencephalography (MEG). However, feasibility and reproducibility of CKC based on electroencephalography (EEG) is still unclear and is the primary object of the present report. Thirteen healthy right-handed volunteers (seven females, 21.7 ± 4.3 yr) participated in two combined MEG/EEG sessions 12.6 ± 1.3 mo apart. Participants' dominant and nondominant index finger was continuously moved at 3 Hz for 4 min separately using a pneumatic-movement actuator. Coherence was …

AdultMalePhysiologyComputer scienceMovementproprioceptionKinematicsElectroencephalographyFunctional Laterality050105 experimental psychologysomatosensoryFingersYoung Adult03 medical and health sciences0302 clinical medicineEvoked Potentials SomatosensorymedicineHumans0501 psychology and cognitive sciencesComputer visionEEGrepeatabilityReproducibilityliikeaistimedicine.diagnostic_testProprioceptiontoistettavuusbusiness.industryGeneral Neuroscience05 social sciencesMagnetoencephalographyReproducibility of ResultsSomatosensory CortexCoherence (statistics)Sciences bio-médicales et agricolesneurotieteetBiomechanical Phenomena3. Good healthkinematicsFeasibility StudiesFemalebiomekaniikkaArtificial intelligencebusiness030217 neurology & neurosurgeryelectroencephalography
researchProduct

Dipole Source Analyses of Early Median Nerve SEP Components Obtained From Subdural Grid Recordings

2010

The median nerve N20 and P22 SEP components constitute the initial response of the primary somatosensory cortex to somatosensory stimulation of the upper extremity. Knowledge of the underlying generators is important both for basic understanding of the initial sequence of cortical activation and to identify landmarks for eloquent areas to spare in resection planning of cortex in epilepsy surgery. We now set out to localize the N20 and P22 using subdural grid recording with special emphasis on the question of the origin of P22: Brodmann area 4 versus area 1. Electroencephalographic dipole source analysis of the N20 and P22 responses obtained from subdural grids over the primary somatosensor…

AdultMalePhysiologyModels NeurologicalSubdural SpaceSomatosensory systemYoung AdultSpecies SpecificityEvoked Potentials SomatosensoryCortex (anatomy)Brodmann area 4medicineAnimalsHumansBrain MappingEpilepsyScalpGeneral NeuroscienceMotor CortexElectroencephalographyArticlesHaplorhiniSomatosensory CortexAnatomyMiddle AgedMagnetic Resonance ImagingCentral sulcusMedian Nervemedicine.anatomical_structureSomatosensory evoked potentialFemalePrimary motor cortexTomography X-Ray ComputedPsychologyNeuroscienceBrodmann areaMotor cortexJournal of Neurophysiology
researchProduct

Cutaneous Painful Laser Stimuli Evoke Responses Recorded Directly From Primary Somatosensory Cortex in Awake Humans

2004

Negative and positive laser evoked potential (LEP) peaks (N2*, P2**) were simultaneously recorded from the primary somatosensory (SI), parasylvian, and medial frontal (MF: anterior cingulate and supplementary motor area) cortical surfaces through subdural electrodes implanted for the surgical treatment of intractable epilepsy. Distribution of the LEP N2*and P2**peaks was estimated to be in cortical areas (SI, parasylvian, and MF) identified by anatomic criteria, by their response to innocuous vibratory stimulation of a finger (v-SEP), and to electrical stimulation of the median nerve (e-SEP). The maximum of the LEP N2*peak was located on the CS, medial (dorsal) to the finger motor area, as …

AdultMalePhysiologyStimulationSomatosensory systemHomunculusEvoked Potentials SomatosensoryPhysical StimulationCortex (anatomy)Reaction TimemedicineHumansWakefulnessEvoked potentialPain MeasurementPhysicsSupplementary motor areaPostcentral gyrusLasersGeneral NeuroscienceSomatosensory CortexAnatomyMiddle AgedElectric Stimulationmedicine.anatomical_structureTouchNociceptorFemaleNeuroscienceJournal of Neurophysiology
researchProduct

Selection of odorants for memory tests on the basis of familiarity, perceived complexity, pleasantness, similarity and identification

2002

In a procedure for the selection of two equivalent sets of familiar and two equivalent sets of unfamiliar odours for use in odour memory studies, 24 naive subjects were first asked to rate the familiarity, perceived complexity and pleasantness of 54 a priori unfamiliar odours and 57 a priori familiar odours and to identify the latter. After selection of the 40 most familiar and the 40 least familiar odours, the subjects sorted each of these two sets into groups of similar odours. Their results were analysed by multidimensional scaling and cluster analysis and each set was divided into two recognition sets that had the same degree of similarity between target and distractor odours and that h…

AdultMalePhysiologymedia_common.quotation_subject050105 experimental psychology03 medical and health sciencesBehavioral Neuroscience0302 clinical medicineCognitionMemoryPhysiology (medical)PerceptionSimilarity (psychology)Selection (linguistics)Humans0501 psychology and cognitive sciencesMultidimensional scalingSet (psychology)Equivalence (measure theory)ComputingMilieux_MISCELLANEOUSmedia_commonRecognition memoryAgedCommunicationbusiness.industryMemoria05 social sciencesMiddle AgedSensory SystemsSmell[CHIM.OTHE] Chemical Sciences/OtherMental RecallOdorantsFemalebusinessPsychology[CHIM.OTHE]Chemical Sciences/Other030217 neurology & neurosurgeryCognitive psychology
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct