The planimetric Grothoff's criteria by cardiac magnetic resonance can improve the specificity of left ventricular non-compaction diagnosis in thalass…
2020
We differentiated the left ventricle non-compaction (LVNC) from hypertrabeculated myocardium due to a negative remodeling in thalassemia intermedia (TI) patients applying linear and planimetric criteria and comparing the cardiovascular magnetic resonance (CMR) findings. CMR images were analyzed in 181 TI patients enrolled in the Myocardial Iron Overload in Thalassemia Network and 27 patients with proved LVNC diagnosis. The CMR diagnostic criteria applied in TI patients were: a modified linear CMR Petersen’s criterion based on a more restrictive ratio of diastolic NC/C > 2.5 at segmental level and the combination of planimetric Grothoff’s criteria (percentage of trabeculated LV myocardial…
Allocentric time-to-contact and the devastating effect of perspective
2014
AbstractWith regard to impending object–object collisions, observers may use different sources of information to judge time to contact (tC). We introduced changes of the observer’s vantage point to test among three sets of hypotheses: (1) Observers may use a distance-divided-by-velocity algorithm or, alternatively, elaborated τ-formulae, all of which give exact tC information; (2) observers may use simple τ-formulae (i.e., formulae of the type: visual angle divided by its own first temporal derivative); (3) observers may capitalize on non-τ variables. Hypotheses (2) and (3) imply specific patterns of errors. We presented animated, impending collisions between a moving object and a stationar…
Intra- and inter-rater reliability of thoracic spine mobility and posture assessments in subjects with thoracic spine pain
2020
Abstract Background The thoracic spine (TS) has been neglected in the study of the spine despite its essential role in the stability and posture of the entire spinal complex. Therefore, there is an inevitable need to investigate the reproducibility of different thoracic spinal posture measures used in subjects with TS pain. Methods Thirty-two subjects (16 females and 16 males, mean age 39 years) were evaluated by two physiotherapists on the same day to gauge inter-rater reliability and on two consecutive days to gauge intra-rater reliability. TS posture was assessed by observation, and thoracic spine mobility was measured by manual assessment of segmental flexion and extension mobility in a…
Characterization of hypoechoic focal hepatic lesions in patients with fatty liver: diagnostic performance and confidence of contrast-enhanced ultraso…
2007
The objective of this study was to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) to characterize hypoechoic focal hepatic lesions (HFHL) in fatty liver (FL). A study group of 105 patients with FL and 105 HFHLs (52 malignant and 53 benign) underwent CEUS after SonoVue administration. Two blinded readers independently reviewed baseline ultrasound (US) and CEUS scans and classified each lesion as malignant or benign on a five-point scale of confidence, and recorded whether further imaging work-up was needed. Sensitivity, specificity, areas under the receiver operating characteristic (ROC) curve (A (z)), and interobserver agreement were calculated. We observed that th…
Differences between orthopaedic evaluation and radiological reports of conventional radiographs in patients with minor trauma admitted to the emergen…
2017
Abstract Introduction During night and on weekends, in our emergency department there is no radiologist on duty or on call: thus, X-ray examinations (XR) are evaluated by the orthopaedic surgeon on duty and reported the following morning/monday by radiologists. The aim of our study was to examine the discrepancy rate between orthopaedists and radiologists in the interpretation of imaging examinations performed on patients in our tertiary level orthopaedic institution and the consequences of delayed diagnosis in terms of patient management and therapeutic strategy. Materials and methods We retrospectively reviewed all cases of discrepancy between orthopaedists and radiologists, which were ca…
The shoulder medial rotation test: an intertester and intratester reliability study in overhead athletes with chronic shoulder pain.
2013
The purpose of this study was to examine intertester and intratester reliability of the shoulder medial rotation test (MRT) and reliability differences depending on examiner expertise.Seventeen athletes with chronic shoulder pain participated in the study. Four independent observers with different experience levels simultaneously rated MRT performance as "correct" or "incorrect," after a standardized assessment protocol, the same day (for intertester reliability) and in a 7-day interval (for intratester reliability).The intrarater reliability was admissible for 2 experts and one novice, with κ values ranging between 0.32 to 0.76 and poor for one novice (κ0). Interrater agreement for all 4 a…
Hepatic focal nodular hyperplasia: contrast-enhanced ultrasound findings with emphasis on lesion size, depth and liver echogenicity
2010
To correlate contrast-enhanced ultrasound (CEUS) findings of hepatic focal nodular hyperplasia (FNH) with lesion size, depth and liver echogenicity and to compare CEUS with baseline US. Two radiologists evaluated baseline US and CEUS examinations of 92 FNHs (mean size: 3.1 +/- 1.7 cm) in 71 patients (59 women and 12 men) to detect the "spoke-wheel" sign, central scar and feeding vessel. The FNHs were grouped and analysed by dimension, depth and liver echogenicity. At least one sign could be detected at CEUS in 27 out of 36 (75%) FNHs larger than 3 cm and in 17 out of 56 (30%) FNH measuring 3 cm or less (p 0.05) as well as between CEUS or baseline US/CD with regard to lesion size, depth or l…
Computed Virtual Chromoendoscopy for Classification of Small Colorectal Lesions: A Prospective Comparative Study
2007
Standard colonoscopy offers no reliable discrimination between neoplastic and nonneoplastic colorectal lesions. Computed virtual chromoendoscopy with the Fujinon intelligent color enhancement (FICE) system is a new dyeless imaging technique that enhances mucosal and vascular patterns. This prospective trial compared the feasibility of FICE, standard colonoscopy, and conventional chromoendoscopy with indigo carmine in low- and high-magnification modes for determination of colonic lesion histology.Sixty-three patients with 150 flat or sessile lesions less than 20 mm in diameter were enrolled. At colonoscopy, each lesion was observed with six different endoscopic modalities: standard colonosco…
Interexaminer reliability of low back pain assessment using the McKenzie method.
2002
STUDY DESIGN A test-retest design was used. OBJECTIVE To assess interexaminer reliability of the McKenzie method for performing clinical tests and classifying patients with low back pain. SUMMARY OF BACKGROUND DATA Clinical methods and tests classifying patients with nonspecific low back pain have been based mainly on symptom duration or extent of pain referral. The McKenzie mechanical diagnostic and classification approach is a widely used noninvasive, low-technology method of assessing patients with low back pain. However, little is known about the interexaminer reliability of the method, previous studies having yielded conflicting results. METHODS For this study, 39 volunteers with low b…
Reliability of the Dynamic Gait Index (Finnish version) in individuals with neurological disorders
2012
To produce a Finnish version of the Dynamic Gait Index (DGI) and establish its reliability in people with neurological disorders affecting balance.A consecutive sample of 33 participants in inter-rater and 30 participants in intra-rater sample were tested. The DGI was administered in two testing sessions 1-2 h apart. Reliability was assessed with the intra-class correlation coefficient (ICC), Bland-Altman 95% limits of agreement, coefficient of reproducibility (CR), and standard error of the mean (SEM).The instructions from the original DGI were preserved during the translation process with no need for cultural adaptations. The relative reliability of the total scores proved to be high in i…