Search results for "Shield"

showing 10 items of 177 documents

Metrological Properties of the Test Setup for Determination Shielding Effectiveness of the Industrial Cable Connectors

2017

Abstract The paper presents results related to assessment of the repeatability and reproducibility of the measurement test setup for determination the relative value of the shielding effectiveness coefficient of the industrial connectors. The construction of the proposed test setup, the measurement method and the procedure for the analysis of measurement results were described. To determine the value of the repeatability and reproducibility coefficient, the two–way analysis of variance was used, which additionally allows for an assessment of the influence of individual sources of variance. The measurements and their analysis were conducted for several frequencies in the range up to 1 GHz. A…

010302 applied physicsTest setupEngineeringReproducibilitybusiness.industry020208 electrical & electronic engineeringMechanical engineering02 engineering and technologyRepeatabilityVariance (accounting)01 natural sciencesReliability engineeringMetrology0103 physical sciencesElectromagnetic shielding0202 electrical engineering electronic engineering information engineeringRange (statistics)Measurement uncertaintybusinessInternational Journal of Electronics and Telecommunications
researchProduct

Antineutrino monitoring of spent nuclear fuel

2016

Military and civilian applications of nuclear energy have left a significant amount of spent nuclear fuel over the past 70 years. Currently, in many countries world wide, the use of nuclear energy is on the rise. Therefore, the management of highly radioactive nuclear waste is a pressing issue. In this letter, we explore antineutrino detectors as a tool for monitoring and safeguarding nuclear waste material. We compute the flux and spectrum of antineutrinos emitted by spent nuclear fuel elements as a function of time, and we illustrate the usefulness of antineutrino detectors in several benchmark scenarios. In particular, we demonstrate how a measurement of the antineutrino flux can help to…

010308 nuclear & particles physicsNuclear engineeringDetectorGeneral Physics and AstronomyFluxRadioactive wasteFOS: Physical sciences01 natural sciencesSpent nuclear fuel3. Good healthHigh Energy Physics - ExperimentOverburdenHigh Energy Physics - Experiment (hep-ex)High Energy Physics - PhenomenologyHigh Energy Physics - Phenomenology (hep-ph)0103 physical sciencesElectromagnetic shieldingEnvironmental scienceNeutrinoNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentLeakage (electronics)
researchProduct

Abiotic and biotic controls on methane formation down to 2.5 km depth within the Precambrian Fennoscandian Shield

2017

Abstract Despite a geological history characterised by high temperature and pressure processes and organic carbon deprived crystalline bedrock, large amounts of hydrocarbons are found in deep groundwaters within Precambrian continental shields. In many sites, methane comprises more that 80% of the dissolved gas phase reaching concentrations of tens of mmol l −1 . In this study, we used isotopic methods to study the carbon isotope systematics and sources of crustal methane within the Fennoscandian Shield. The main study sites were the Outokumpu Deep Drill Hole and the Pyhasalmi mine in Finland, both of which allow groundwater sampling down to 2.5 km depth and have been previously studied for…

010504 meteorology & atmospheric sciencesMethanogenesista1171GeochemistryMineralogychemistry.chemical_element010502 geochemistry & geophysicsmetaani01 natural sciencesMethanechemistry.chemical_compoundPrecambrianPyhäsalmikalsiittiGeochemistry and PetrologyNatural gasgrafiitti0105 earth and related environmental sciencesTotal organic carbongraphitebusiness.industrymethane15. Life on landethaneOutokumpuchemistryvetycarbon isotopes13. Climate actionIsotopes of carbonhydrogenFennoscandian shieldbusinesscalciteCarbonGroundwaterGeologyGeochimica et Cosmochimica Acta
researchProduct

Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.

2017

Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…

0106 biological sciencesbusiness.industryEquivalent dosemedicine.medical_treatmentBrachytherapyBrachytherapyPublic Health Environmental and Occupational HealthTreatment roomGeneral MedicineRadiation Dosage01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation ProtectionElectromagnetic shieldingCalibrationmedicineHumansScattering RadiationNuclear medicinebusinessRadiometryWaste Management and Disposal010606 plant biology & botanyJournal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Stable radical anions generated from a porous perylenediimide metal-organic framework for boosting near-infrared photothermal conversion

2019

Radical anions of electron-deficient systems are widely used, but are easily reoxidized upon exposure to air. Therefore, the stabilization of radical anions under ambient conditions is of great significance, but still remains a scientific challenge. Herein, perylenediimide is employed to prepare a crystalline metal-organic framework for stabilizing radical anions without extensive chemical modification. The porous, three-dimensional framework of perylenediimide can trap electron donors such as amine vapors and produce radical anions in-situ through photo-induced electron transfer. The radical anions are protected against quenching by shielding effect in air and remain unobstructed in air fo…

0301 basic medicineMultidisciplinaryMaterials scienceScienceQNear-infrared spectroscopyGeneral Physics and AstronomyChemical modification02 engineering and technologyGeneral ChemistryPhotothermal therapy021001 nanoscience & nanotechnologyPhotochemistryArticleGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciencesElectron transfer030104 developmental biologyShielding effectMetal-organic frameworkAmine gas treatinglcsh:Q0210 nano-technologyPorositylcsh:ScienceNature Communications
researchProduct

Can hip resurfacing be safely revised with short-stem total hip arthroplasty? A case series of six patients.

2021

Abstract Background The usage of short stems in primary total hip arthroplasty (THA) has constantly gained popularity over the last decade, however, to date, short stems are not eligible to be used as revision implants. The aim of this study was to retrospectively evaluate the outcome of revision surgery of failed hip resurfacing arthroplasty (HRA) using short-stem THA. Methods In a single center, retrospective analysis, 6 consecutive patients who were treated with a calcar-guided short stem after failure of HRA were evaluated. The mean follow-up was 3.25 years (SD 0.45). Patient reported outcome measurements (PROMs) were recorded using the Harris hip score (HHS) and The Western Ontario and…

030222 orthopedicsmedicine.medical_specialtyWOMACbusiness.industryVisual analogue scalemedicine.medical_treatment030229 sport sciencesOsteoarthritisStress shieldingmedicine.diseaseArthroplastyHip resurfacingSurgery03 medical and health sciences0302 clinical medicineHarris Hip ScoreMedicineOrthopedics and Sports MedicinePatient-reported outcomebusinessJournal of orthopaedics
researchProduct

Anulación del privacy shield en las transferencias internacionales de datos : ¿presenciamos un desplazamiento fáctico de la responsabilidad?

2021

This study provides a comprehensive analysis of international transfers of personal data to third countries or international organizations due to new privacy regulation. More specifically, it analyzes the effects on this regulatory scheme of the annulment of the Privacy Shield in the transatlantic information movements between the European Union and the United States and how this implies, in fact, a transfer of responsibility to the controller

:CIENCIAS JURÍDICAS [UNESCO]international transfers2070-8157 22082 Revista Boliviana de Derecho 565487 2021 31 7730066 Anulación del privacy shield en las transferencias internacionales de datos ¿presenciamos un desplazamiento fáctico de la responsabilidad? Rodríguez AyusoEE. UU.US 476 503RGPDtransferencias internacionalesPrivacyUNESCO::CIENCIAS JURÍDICASin factit analyzes the effects on this regulatory scheme of the annulment of the Privacy Shield in the transatlantic information movements between the European Union and the United States and how this impliesJuan Francisco This study provides a comprehensive analysis of international transfers of personal data to third countries or international organizations due to new privacy regulation. More specificallya transfer of responsibility to the controller Dato personalGDPRUEEU
researchProduct

Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.

2015

To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…

Adultmedicine.medical_specialtymedicine.medical_treatmentBrachytherapyBrachytherapyBiophysicsGeneral Physics and AstronomyFetal positionBreast NeoplasmsIonizing radiationLead shieldingBreast cancerFetusRadiation ProtectionPregnancymedicineHumansRadiology Nuclear Medicine and imagingRadiometrybusiness.industryRadiotherapy Planning Computer-AssistedRadiotherapy DosageGeneral Medicinemedicine.diseaseIridium RadioisotopesSurgeryRadiation therapyPregnancy ComplicationsElectromagnetic shieldingFemaleImplantbusinessNuclear medicinePhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
researchProduct

Neoproterozoic Rosetta Gabbro from northernmost Arabian–Nubian Shield, south Jordan : Geochemistry and petrogenesis

2017

An Ediacaran mafic intrusion of south Jordan is a distinctive appinitic igneous rock with a possibly unique texture, characterized by spherical clots up to 40 mm in diameter composed of amphibole cores from which plagioclase euhedra radiate; we call it the Rosetta Gabbro. It is exposed as a small (ca. 750 m(2)) outcrop in the Neoproterozoic basement of south Jordan. A second outcrop of otherwise similar gabbro is located about 400 m to the north of the Rosetta Gabbro, but it lacks the distinctive texture. The Rosetta Gabbro could represent a magma pipe. It intrudes the Aqaba Complex (similar to 600 Ma) granitoids and metasediments of the Janub Metamorphic Complex (633-617 Ma). The gabbro is…

Amphibole microchemistry010504 meteorology & atmospheric sciencesGeochemistryRosetta Gabbroengineering.material010502 geochemistry & geophysicsAppinite01 natural sciencesMagmatic waterGeochemistry and PetrologyPlagioclaseLA-ICP-MSAmphibole0105 earth and related environmental sciencesBasaltGabbroGeovetenskap och miljövetenskapGeologyArabian-Nubian shieldIgneous rockWater-rich magmaMagmaengineeringMaficEarth and Related Environmental SciencesGeology
researchProduct

Understanding the ring current effects on magnetic shielding of hydrogen and carbon nuclei in naphthalene and anthracene

2008

The local response to an external magnetic field normal to the molecular plane of naphthalene and anthracene was investigated via current density and magnetic shielding density maps. The Biot-Savart law shows that the deshielding caused by pi-ring currents in naphthalene is stronger for alpha- than for beta-protons due to geometrical factors. The shielding tensor of the carbon nuclei in both molecules is strongly anisotropic and its out-of-plane component determines the up-field chemical shift of (13)C in nuclear magnetic resonance spectra. The pi-ring currents flowing beyond the C-skeleton in front of a probe carbon nucleus, and on remote parts of the molecular perimeter, yield positive co…

AnthraceneHydrogennaphthalenechemistry.chemical_elementGeneral ChemistryAromatic ring currentMagnetic fieldComputational Mathematicschemistry.chemical_compoundchemistrycurrent density mapsElectromagnetic shieldingproton and carbon chemical shiftAtomic physicsnaphthalene; ring currents; proton and carbon chemical shift; current density mapsCarbonCurrent densityring currentsRing currentJournal of Computational Chemistry
researchProduct