Search results for "Signal processing"
showing 10 items of 2451 documents
Subthreshold low frequency repetitive transcranial magnetic stimulation selectively decreases facilitation in the motor cortex
2002
Objective: To investigate the modulatory effect of a subthreshold low frequency repetitive transcranial magnetic stimulation (rTMS) train on motor cortex excitability. Methods: The study consisted of two separate experiments. Subjects received a 10 min long subthreshold 1Hz rTMS train. In the first experiment, (single pulse paradigm), cortical excitability was assessed by measuring the amplitude of motor evoked potentials (MEPs) before and after the rTMS train. In the second experiment, a paired pulse paradigm was employed. Results: Corticospinal excitability, as measured by the MEP amplitude, was reduced by the rTMS train (experiment 1), with a significant effect lasting for about 10 min a…
The effectiveness of a novel optical probe in subgingival calculus detection
2008
: Objectives: The aim of the present study was to evaluate the effectiveness of a novel optical calculus detection system under in vivo conditions. Methods: One hundred and seventy-six tooth surfaces from 44 adult teeth that were indicated for extraction were selected for the present study. The patients were randomly assigned to one of the two experimental groups. In group A (n = 96), clinical presence or absence of subgingival calculus deposits was determined using the light-emitting diode-based optical probe (OP). In group B (n = 80), the subgingival deposits were first recorded with the OP followed by root surface debridement until no subgingival deposits could be detected by the devi…
Dimension reduction: additional benefit of an optimal filter for independent component analysis to extract event-related potentials.
2011
The present study addresses benefits of a linear optimal filter (OF) for independent component analysis (ICA) in extracting brain event-related potentials (ERPs). A filter such as the digital filter is usually considered as a denoising tool. Actually, in filtering ERP recordings by an OF, the ERP' topography should not be changed by the filter, and the output should also be able to be modeled by the linear transformation. Moreover, an OF designed for a specific ERP source or component may remove noise, as well as reduce the overlap of sources and even reject some non-targeted sources in the ERP recordings. The OF can thus accomplish both the denoising and dimension reduction (reducing the n…
Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist
2019
Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…
High definition plus colonoscopy combined with i-scan tone enhancement vs. high definition colonoscopy for colorectal neoplasia: A randomized trial
2014
High definition endoscopy is the accepted standard in colonoscopy. However, an important problem is missed polyps.Our objective was to assess the additional adenoma detection rate between high definition colonoscopy with tone enhancement (digital chromoendoscopy) vs. white light high definition colonoscopy.In this prospective randomized trial patients were included to undergo a tandem colonoscopy. The first exam was a white light colonoscopy with removal of all visualized polyps. The second examination was randomly assigned in a 1:1 ratio as either again white light colonoscopy (Group A) or colonoscopy with tone enhancement (Group B). Primary endpoint was the adenoma detection rate during t…
Cardiovascular effects of impulse noise, road traffic noise, and intermittent pink noise at LAeq = 75 dB, as a function of sex, age, and level of anx…
1992
In a previous paper, in which the experimental conditions of the present research are fully described (Parrot et al., this issue), heart rate (HR) was studied in 60 male and in 60 female subjects in response to a pile-driver noise (P), a gunfire noise (G), a road traffic noise (T), and an intermittent pink noise (R), all noises being emitted at the same LAeq = 75 dB for 15 min. Digital pulse level (PL) responses were concomitantly surveyed by the use of pulse oximetry, allowing continuous arterial oxygen saturation (SaO2) readings. An index of pulse reactivity (PRI) could be calculated. Arterial blood pressure was measured 7 times from the beginning to the end of each trial. At rest, within…
Evidence of unilateral isolated utricular hypofunction
2010
The findings demonstrate that an enduring unilateral utricular dysfunction, possibly together with canal hypofunction, can occur after labyrinthine disease or injury. They also suggest that unilateral, isolated utricular dysfunction - or utricle paresis - can occur, representing a novel entity in the differential diagnosis of peripheral vestibular function. The occurrence of subjective visual vertical (SVV) asymmetry in the presence of symmetric vestibular evoked myogenic potentials (VEMPs) also confirms that the information from the utricles, rather than the saccules, dominates SVV estimation.To determine the incidence of unilateral utricular hypofunction.The retrospective clinical study d…
Mentally represented motor actions in normal aging: III. Electromyographic features of imagined arm movements.
2009
Abstract Motor imagery is a cognitive process during which subjects mentally simulate movements without actually performing them. Here, we investigated the temporal and electromyographic (EMG) features of imagined arm movements in healthy elderly adults. Twelve young (mean age: 24.0 ± 1.3 years) and 12 elderly (mean age: 67.0 ± 4.5 years) participants executed and mentally simulated, with their right and left arms and as fast and as accurately as possible, arm pointing movements between three targets located in the frontal plane. We used the mental chronometry paradigm as an indicator of the accuracy of the motor imagery process (i.e. isochrony between executed and imagined movements) and t…
Neuromuscular characteristics and fatigue in endurance and sprint athletes during a new anaerobic power test
1994
The purpose of this study was to investigate neuromuscular and energy performance characteristics of anaerobic power and capacity and the development of fatigue. Ten endurance and ten sprint athletes performed a new maximal anaerobic running power test (MARP), which consisted ofn x 20-s runs on a treadmill with 100-s recovery between the runs. Blood lactate concentration [la−]b was measured after each run to determine submaximal and maximal indices of anaerobic power (P 3mmol·1 −1,P5mmol·1 −1,P10mmol·1 −1andP max) which was expressed as the oxygen demand of the runs according to the American College of Sports Medicine equation: the oxygen uptake (ml·kg−1·min−1)=0.2·velocity (m·min−1) +0.9·s…
Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.
2011
International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…