Search results for "Silicon"
showing 10 items of 1391 documents
Switching dynamics of dark-pulse Kerr frequency comb states in optical microresonators
2021
Dissipative Kerr solitons are localized structures that exist in nonlinear optical cavities. They lead to the formation of microcombs - chip-scale frequency combs that could facilitate precision frequency synthesis and metrology by capitalizing on advances in silicon photonics. Previous demonstrations have mainly focused on anomalous dispersion cavities. Notwithstanding, localized structures also exist in the normal dispersion regime in the form of circulating dark pulses, but their physical dynamics is far from being understood. Here, we explore dark-pulse Kerr combs generated in normal dispersion optical microresonators and report the discovery of reversible switching between coherent dar…
Dielectric versus topographic contrast in near-field microscopy
1996
Using a fully vectorial three-dimensional numerical approach (generalized field propagator, based on Green's tensor technique), we investigate the near-field images produced by subwavelength objects buried in a dielectric surface. We study the influence of the object index, size, and depth on the near field. We emphasize the similarity between the near field spawned by an object buried in the surface (dielectric contrast) and that spawned by a protrusion on the surface (topographic contrast). We show that a buried object with a negative dielectric contrast (i.e., with a smaller index than its surrounding medium) produces a near-field image that is reversed from that of an object with a posi…
Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors
2007
A very high resolution positron emission tomography (PET) scanner for small animal imaging based on the idea of inserting a ring of high-granularity solid-state detectors into a conventional PET scanner is under investigation. A particularly interesting configuration of this concept, which takes the form of a degenerate Compton camera, is shown capable of providing sub-millimeter resolution with good sensitivity. We present a Compton PET system and estimate its performance using a proof-of-concept prototype. A prototype single-slice imaging instrument was constructed with two silicon detectors 1 mm thick, each having 512 1.4 mm x 1.4 mm pads arranged in a 32 x 16 array. The silicon detector…
The Cryogenic AntiCoincidence Detector Project for ATHENA+: An Overview Up to the Present Status
2014
ATHENA+ is a space mission proposal for the next ESA L2-L3 slot. One of the focal plane instruments is the X-ray integral field unit (X-IFU) working in the energy range 0.3–10 keV. It is a multi-array based on TES detectors aimed at characterizing faint or diffuse sources (e.g. WHIM or galaxy outskirt). The X-IFU will be able to achieve the required sensitivity if a low background is guaranteed. The studies performed by GEANT4 simulations depict a scenario where the use of an active anticoincidence (AC) is mandatory to reduce the background expected in L2 orbit down to the goal level of 0.005 cts cm $$^{-2}$$ s $$^{-1}$$ keV $$^{-1}$$ . This is possible using a cryogenic anticoincidence (…
Supercontinuum generation in silicon waveguides relying on wave-breaking
2015
Four-wave-mixing processes enabled during optical wave-breaking (OWB) are exploited in this paper for supercontinuum generation. Unlike conventional approaches based on OWB, phase-matching is achieved here for these nonlinear interactions, and, consequently, new frequency production becomes more efficient. We take advantage of this kind of pulse propagation to obtain numerically a coherent octave-spanning mid-infrared supercontinuum generation in a silicon waveguide pumping at telecom wavelengths in the normal dispersion regime. This scheme shows a feasible path to overcome limits imposed by two-photon absorption on spectral broadening in silicon waveguides.
External Noise Effects in Silicon MOS Inversion Layer
2013
The effect of the addition of an external source of correlated noise on the electron transport in silicon MOS inversion layer, driven by a static electric field, has been investigated. The electron dynamics is simulated by a Monte Carlo procedure which takes into account non-polar optical and acoustic phonons. In our modelling of the quasi-two-dimensional electron gas, the potential profile, perpendicular to the MOS structure, is assumed to follow the triangular potential approximation. We calculate the changes in both the autocorrelation function and the spectral density of the velocity fluctuations, at different values of noise amplitude and correlation time. The findings indicate that, t…
First coincidences in pre-clinical Compton camera prototype for medical imaging
2003
Abstract Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500 μm thick, 256 pad silicon detector with pad size of 1.4×1.4 mm 2 , combined with a 15×15×1 cm 3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (…
JEM-X: three years in space
2006
We report on the technical and scientific performance of JEM-X, the X-ray monitor on ESA's INTEGRAL mission. INTEGRAL has now been in orbit for more than three years, and the mission is foreseen to be extended until the end of 2010. Overall, JEM-X performs very well, and can be expected to continue to do so for the duration of the mission. We discuss in some detail the operational experiences and the problems encountered with the microstrip detectors caused by the space environment and give one example of the interesting scientific results obtained. The analysis software is still being improved on, and we discuss briefly the significance of these improvements.
Time-multiplexed chromatic-controlled axial diffractive optical elements
2010
Programmable diffractive optical elements DOEs with axial response have many interesting applications, including diffractive lenses, axicons, and optical tweezers. In all these cases, it is essential to properly select the modulation configuration of the spatial light modulator SLM where the DOE is displayed, in order to avoid the undiffracted zero order component that appears on axis and overlaps the desired axial response. However, in general, the chromatic dispersion in liquid crystal SLMs prevents the cancellation of the zero order for a broadband light source, thus limiting the possibilities for polychromatic program- mable axial DOEs. We operate a ferroelectric liquid crystal on silic…
The Cryogenic Anticoincidence Detector for ATHENA-XMS
2012
The TES cryogenic detectors, due to their high spectral resolution and imaging capability in the soft X-ray domain, are the reference devices for the next proposed space missions whose aims are to characterize the spectra of faint or diffuse sources. ATHENA is the re-scoped IXO mission, and one of its focal plane instrument is the X-ray Microcalorimeter Spectrometer (XMS) working in the energy range 0.3-10 keV. XMS will be able to achieve the proposed scientific goals if a background lower than 0.02 cts/cm2/s/keV is guaranteed. The studies performed by GEANT4 simulations depict a scenario where it is mandatory to use an active Anti-Coincidence (AC) to reduce the expected background in the L…