Search results for "Silicone"
showing 8 items of 78 documents
Tear Film Surface Quality in Modern Daily Disposable Contact Lens Wear
2021
Objectives As reported previously, tear film surface quality (TFSQ) should be considered in contact lens (CL) fitting. This study followed noninvasive keratograph tear film break-up time (NIKBUT) in CL wearers for 12 months to validate its clinical utility in predicting CL performance. Methods Fifty-five subjects (M/F=17/38) aged 26±4 years were prescribed silicone hydrogel or hydrogel CLs. The study included baseline measurements without CLs; 2 visits for CL fitting and control; follow-up after 3, 6, and 12 months of CL wear; and postwear visit without CLs. Ocular Surface Disease Index (OSDI), 8-Item Contact Lens Dry Eye Questionnaire (CLDEQ-8), first and mean NIKBUT (F/M-NIKBUT), fluoresc…
Effectiveness of semi-permeable dressings to treat radiation-induced skin reactions. A systematic review
2017
The aim of this systematic review is to assess the available evidence concerning the effectiveness of semi-permeable dressings, on the full range of skin reactions, related to radiation therapy in cancer patients, from local erythema to moist desquamation, including subjective symptoms such as pain, discomfort, itchiness, burning and the effect on daily life activities. The bibliographic search was carried out looking for Randomised Clinical Trials (RCTs) indexed in PubMed, Cinhal, Cochrane plus and Biblioteca Nacional de Salud, published in the English and Spanish language, between 2010 and 2015. Data extraction and evaluation of study quality was undertaken by peer reviewers using the Cri…
Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.
2008
Purpose: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure. Methods: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared b…
Gastric Banding for Treatment of Morbid Obesity: Preliminary Results.
1995
Background: gastric banding (GB) has been used for treatment of morbid obesity. Methods: a banding device, introduced by Broadbent and consisting of a self-blocking nylon strip covered with a silicone tube, was used in 13 patients who have completed 1-year follow-up. This device was used for its mechanical properties, biocompatibility, ease of insertion and low cost. Results: at 1 year, mean excess weight loss was 51.6%, with all but one patient losing more than 25% of excess weight. Associated illnesses resolved. There were two complications (15%): one patient required band removal for self-induced vomiting and one patient required repair of an incisional hernia. Conclusions: GB has had go…
A diagnostic trap for the dermatopathologist: granulomatous reactions from cutaneous microimplants for cosmetic purposes.
2007
We present a case of late granulomatous reactions from silicone that first appeared in a site different from that of the injection causing an incorrect diagnosis of liposarcoma in the beginning. The histological picture was a cystic-macrophagic granuloma in both the injection site (upper lip) and the migrating site (paranasal regions). We think that the foreign body has undergone an antigravity migration from the upper lip to the right paranasal region. To our knowledge, such a phenomenon has not been yet reported in literature.
Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes
2006
Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…
The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials
2008
The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…