Search results for "Sinus rhythm"
showing 10 items of 49 documents
Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography
2006
OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduct…
Delayed Anaerobic Threshold in Heart Failure Patients With Atrial Fibrillation
2016
PURPOSE To assess whether atrial fibrillation (AF) in heart failure (HF) affects oxygen uptake at anaerobic threshold ((Equation is included in full-text article.)O2 AT) and heart rate (HR) kinetics. METHODS A total of 15 patients with HF and AF and 18 with HF and sinus rhythm (SR) performed a maximal incremental and 2 constant workload cycle ergometer cardiopulmonary exercise tests (below and above AT, at 25% and 75% of maximal workload, respectively). At constant workload tests, kinetics of (Equation is included in full-text article.)O2 and HR were assessed by calculating time constant (τ). RESULTS HF patients with AF showed a similar peak (Equation is included in full-text article.)O2 to…
Prognostic Role of Subsequent Atrial Tachycardias Occurring During Ablation of Persistent Atrial Fibrillation
2013
Background— The role of subsequent atrial tachycardias (AT) in the context of persistent atrial fibrillation (AF) remains undetermined. This study evaluated the prognostic role of subsequent ATs for arrhythmia recurrences after catheter ablation of persistent AF. Methods and Results— A total of 110 patients with persistent AF (63±9 years; 22 women; 61 long-lasting persistent AF) underwent pulmonary vein isolation followed by electrogram-guided ablation. After AF terminated to AT, patients were separated by the randomization protocol to receive either direct cardioversion (group A) or further ablation of subsequent ATs to sinus rhythm (group B). After a mean follow-up of 20.1±13.3 months af…
Atrial fibrillation is associated with cardiac hypoxia.
2008
BACKGROUND: Atrial fibrillation (AF), the most common human arrhythmia, is responsible for substantial morbidity and mortality and may be promoted by selective atrial ischemia and atrial fibrosis. Consequently, we investigated markers for hypoxia and angiogenesis in AF. METHODS: Right atrial appendages (n=158) were grouped according to heart rhythm [sinus rhythm (SR) or AF]. The degree of fibrosis and microvessel density of all patients were determined morphometrically using Sirius-Red- and CD34/CD105-stained sections, respectively. Next, sections (n=77) underwent immunostaining to detect hypoxia- and angiogenesis-related proteins [hypoxia-inducible factor (HIF)1 alpha, HIF2 alpha, vascular…
Arrhythmia Termination Versus Elimination of Dormant Pulmonary Vein Conduction as a Procedural End Point of Catheter Ablation for Paroxysmal Atrial F…
2015
Background— Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. Methods and Results— A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting ex…
Advanced interatrial block predicts new-onset atrial fibrillation and ischemic stroke in patients with heart failure: The “Bayes' Syndrome-HF” study
2018
Advanced interatrial block (IAB) is characterized by a prolonged (≥120 ms) and bimodal P wave in the inferior leads. The association between advanced IAB and atrial fibrillation (AF) is known as “Bayes' Syndrome”, and there is scarce information about it in heart failure (HF). We examined the prevalence of IAB and whether advanced IAB could predict new-onset AF and/or stroke in HF patients. Methods and results: The prospective observational “Bayes' Syndrome-HF” study included consecutive outpatients with chronic HF. The primary endpoints were new-onset AF, ischemic stroke, and the composite of both. A secondary endpoint included all-cause death alone or in combination with the primary endpo…
Prevalence of atrial fibrillation and use of antithrombotics in hypertensive patients agedor=65 years. The FAPRES trial.
2010
Introduction and objectives. Age and arterial hypertension are two of the main factors associated with atrial fibrillation and an increased risk of embolism. The objective of this study was to determine the prevalence of atrial fibrillation and the extent of antithrombotic use in hypertensive patients aged ≥65 years in the Spanish region of Valencia. Methods. Each study investigator enrolled the first three hypertensive patients aged ≥65 years who came for a consultation on the first day of each week for 5 weeks. Each patient’s risk factors, history of cardiovascular disease, CHADS2 score and medical treatment were noted and an ECG was recorded. Data were analyzed centrally. A patient was r…
Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?
1998
UNLABELLED In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P…
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…
Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiog…
2005
One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent multislice computed tomography of the heart and conventional coronary angiography were retrospectively selected. The population was divided into 2 groups depending on their calcium score (CS) (e.g., low CS and high CS). The diagnostic accuracy of multislice computed tomographic scans for detecting significant lesions (>50% lumen reduction) in both groups was compared with quantitative coronary angiography. The sensitivity and specificity of multislice computed tomography were 90% and 92%, and 97% and 91% for low and high CS groups, respectively.