The application of molecular imprinting technology to solid phase extraction
2001
In parallel to a long lasting search for universal multi-purpose sorbents, the area of solid phase extraction (SPE) is recently experiencing a rapid development of new types of tailor-made class specific or compound-specific sorbents which are designed to respond to the increasing demand for selectivity and efficiency in sample clean-up prior to quantification. An important issue here is the enrichment and clean-up of complex samples, such as environmental waters, sediments, biofluids and foodstuffs prior to detection. This because the analyte is often present in low concentration in a complex mixture of similar compounds and therefore needs to be isolated and enriched in order to be detect…
Polymeric monolithic microcartridges with gold nanoparticles for the analysis of protein biomarkers by on-line solid-phase extraction capillary elect…
2020
In this study, polymeric monoliths with gold nanoparticles (AuNP@monolith) were investigated as microcartridges for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS). “Plug-and-play” microcartridges (7 mm) were prepared from a glycidyl methacrylate (GMA)-based monolithic capillary column (5 cm x 250 µm i.d.), which was modified with ammonia and subsequently functionalized with gold nanoparticles (AuNPs). The performance of these novel microcartridges was evaluated with human transthyretin (TTR), which is a protein related to different types of familial amyloidotic polyneuropathies (FAP). Protein retention depended on…
Determination of organic and inorganic mercury species in water and sediment samples by HPLC on-line coupled with ICP-MS.
2009
This paper describes a preconcentration method for Hg(2+) and MeHg(+) in water samples using sodium diethyldithiocarbamate immobilized in polyurethane foam (PU-NaDDC) and an extraction method for several mercury species in sediment samples, including MeHg(+), EtHg(+) and PhHg(+), which is simple, rapid, and uses a single organic solvent. Separation and measurement were done by high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Initially, the test of recovery was applied using procedures compatible with HPLC. Under the optimum extraction conditions, recoveries of 96.7, 96.3 and 97.3% were obtained for MeHg(+), EtHg(+), and PhHg(+),…
New In-Depth Analytical Approach of the Porcine Seminal Plasma Proteome Reveals Potential Fertility Biomarkers
2018
A complete characterization of the proteome of seminal plasma (SP) is an essential step to understand how SP influences sperm function and fertility after artificial insemination (AI). The purpose of this study was to identify which among characterized proteins in boar SP were differently expressed among AI boars with significantly different fertility outcomes. A total of 872 SP proteins, 390 of them belonging specifically to Sus Scrofa taxonomy, were identified (Experiment 1) by using a novel proteomic approach that combined size exclusion chromatography and solid-phase extraction as prefractionation steps prior to Nano LC-ESI-MS/MS analysis. The SP proteomes of 26 boars showing significan…
Determination of globotriaosylceramide in plasma and urine by mass spectrometry
2009
Abstract Background: Fabry disease is an X-chromosomally inherited lysosomal storage disorder leading to accumulation of glycosphingolipids, mainly globotriaosylceramide (ceramide-trihexoside, Gb3). Concentrations of Gb3 in plasma and urine have been used to diagnose Fabry disease and to monitor enzyme replacement therapy with recombinant α-galactosidase. Methods: Gb3 was purified from plasma or urine by combined liquid extraction/protein precipitation and solid-phase extraction, and was detected by flow-injection analysis electrospray mass spectrometry (MS) using multi-reaction-monitoring. Calibration was performed via standard addition using C17-Gb3 as internal standard. The most abundant…
Determination of microcystins in biological samples by matrix solid-phase dispersion and liquid chromatography–mass spectrometry
2005
A method for the detection and quantification of the microcystins (MCs)-MC-LR, MC-RR and MC-YR-in biological samples by matrix solid-phase dispersion (MSPD) has been developed. The optimum extraction conditions were 500 mg of liver or kidney, C18 bonded silica as dispersant, and a mixture methanol-water (70:30) as eluent. The MCs were determined by liquid chromatography electrospray mass spectrometry (LC/ES/MS). Recoveries of biological extracts at three different spiked levels (1-10 mg kg(-1)) ranged from 40.5 to 87.0% in liver, and from 52.5 to 74.5 in kidney. R.S.D.s were < 15.6% and < 10.6%, respectively. The detection and quantification limits were 0.05 and 0.5 mg kg(-1), for all MCs. …
Investigation of cuticular hydrocarbons from Bagrada hilaris genders by SPME/GC-MS
2007
The cuticular hydrocarbons of male and female Bagrada hilaris Burmeister (Heteroptera: Pentatomidae) were investigated, by headspace solid-phase microextraction followed by gas chromatography-mass spectrometry. Measurements were done with fiber coatings of different polarity after optimization of headspace volumes and extraction temperatures. This resulted in the use of polyacrylate fiber, 22-ml vial as the sample holder, and an extraction temperature of 150 degrees C. The analytical procedures allowed identification of 13 peaks, corresponding to a homologous series of n-alkanes (nC(17)-nC(29)). The hydrocarbon profiles of male and female B. hilaris were qualitatively equal, but marked sex-…
Targeting metabolomics analysis of the sunscreen agent 2-ethylhexyl 4-(N,N-dimethylamino)benzoate in human urine by automated on-line solid-phase ext…
2011
The in vivo metabolism of the xenobiotic agent 2-ethylhexyl 4-(N,N-dimethylamino)benzoate (EDP), a UV filter commonly used in sunscreen cosmetic products, was studied by targeting metabolomics analysis in human urine. The metabolomic study involved the use of urine from male and female volunteers before and after application of an EDP-containing sunscreen cosmetic. The metabolism of EDP in urine was studied by using the triple quadrupole detector in a combination of Precursor Ion Scanning and Neutral Loss Scanning modes, with and without enzymatic hydrolysis. Detected metabolites were subsequently confirmed as glucuronide conjugates of 4-(N,N-dimethylamino)benzoic acid and 4-(N-methylamino)…
Recent applications of carbonaceous nanosorbents for the analysis of mycotoxins in food by liquid chromatography: a short review
2019
Carbonaceous nanomaterials (multi-walled carbon nanotubes (MWCNTs), graphene, and graphene oxide (GO)) have attracted attention over the last decade as adsorbents suitable for the analysis of organic and inorganic pollutants. In the present paper we review methods of mycotoxin analysis that involve sample extraction with carbonaceous nanosorbents, reported from 2011 onwards. Recent studies have highlighted the advantages of magnetically modified MWCNTs and GO in mycotoxin analysis, which may enable sample isolation through magnetic separation, reduce the interaction of nanoparticles, and enhance the recovery of analytes. The papers covered in this review point to promising applications of …
Evaluation of a Multidimensional Solid-Phase Extraction Platform for Highly Selective On-Line Cleanup and High-Throughput LC−MS Analysis of Triazines…
2001
A novel highly selective sample cleanup procedure based on the use of molecularly imprinted polymers (MIPs) as solid-phase extraction materials has been evaluated with respect to its applicability and routine use in environmental analysis. The method comprises the combination of a restricted access material (RAM) and a MIP allowing a selective sample preparation to be achieved in the online mode. This combination is called the size-selective sample separation and solvent switch (six-SPE). The RAM column combines size exclusion and adsorption chromatography, reducing the concentration of matrix molecules by a cutoff of 15 kDa. The MIP column selectively retains the triazine analytes whereas …