Search results for "Spasm"

showing 9 items of 149 documents

Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten

1997

PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…

musculoskeletal diseasesMaterials sciencemedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentmedicine.anatomical_structureNuclear magnetic resonanceSpinal fusionBone qualitymedicineRadiology Nuclear Medicine and imagingCortical boneDual x-ray absorptiometryQuantitative computed tomographyCadaveric spasmNuclear medicinebusinessCancellous boneFixation (histology)RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Morphomechanics of the humero-ulnar joint: I. Joint space width and contact areas as a function of load and flexion angle

1995

BACKGROUND Previous studies have shown that the trochlear notch is deeper than necessary for an exact fit with the humerus. However, humero-ulnar joint space width and contact areas have so far not been quantified for variations in the load and angle of flexion. METHODS Six fresh cadaveric specimens were investigated at 30 degrees, 60 degrees, 90 degrees, and 120 degrees of flexion and at loads of 25 and 500 N, simulating resisted elbow extension. The joint space width and contact were determined, using polyether casting material. RESULTS At 25 N all joints made contact in the ventral and dorsal aspects of the articular surfaces, whereas in the depth of the trochlear notch the joint space w…

musculoskeletal diseasesmedicine.medical_specialtyElbowGeometrymedicine.disease_causeAgricultural and Biological Sciences (miscellaneous)Weight-bearingSurgerymedicine.anatomical_structureTrochlear notchPosition (vector)medicineHumerusAnatomyCadaveric spasmRange of motionJoint (geology)MathematicsThe Anatomical Record
researchProduct

Waterjet dissection in pediatric cranioplasty

2010

Object Waterjet dissection has been shown to separate tissues of different resistance, with preservation of blood vessels. In cranioplasty, separation of subcutaneous tissue and dura mater is often difficult to achieve because the various tissue layers strongly adhere to each other after decompressive craniotomy. In the present study, the potential advantages and drawbacks of the waterjet technique in cranioplasty after craniectomy and duraplasty are addressed. Methods The waterjet effect on fresh human cadaveric dura mater specimens as well as on several dural repair patches was tested in vitro under standardized conditions, with waterjet pressures up to 80 bar. Subsequently, 8 pediatric …

musculoskeletal diseasesmedicine.medical_specialtybusiness.industryDura matermedicine.medical_treatmentMean ageGeneral MedicineDissection (medical)medicine.diseaseCranioplastyCraniosynostosisSurgerymedicine.anatomical_structuremedicineDecompressive craniectomyCadaveric spasmbusinessDecompressive CraniotomyJournal of Neurosurgery: Pediatrics
researchProduct

Bestimmung der Knochenqualität vor Wirbelsäuleninstrumentation - Stellenwert verschiedener in vivo-Methoden

2008

OBJECTIVE: The present investigation should elucidate which assessment technique for bone quality is most appropriate to estimate preoperatively fixation strength of instrumental spine fusions. METHODS: VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pullout force assessment. Bone quality was assessed by Dual Energy X-ray Absorptiometry (DEXA), Quantitative Computed Tomography (QCT), MRT and histomorphometry. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS: Highest correlation was found for cancellous bone density (QCT) (r = 0.72; p < 0.001) and DEXA (r = 0.70; p < 0.001). MRT, cortical bo…

musculoskeletal diseasesmedicine.medical_specialtymedicine.diagnostic_testBone densitybusiness.industrymedicine.medical_treatmentmusculoskeletal systemSurgerymedicine.anatomical_structureSpinal fusionmedicineOrthopedics and Sports MedicineSurgeryCortical boneQuantitative computed tomographyNuclear medicinebusinessCadaveric spasmCancellous boneDual-energy X-ray absorptiometryFixation (histology)Zeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement

1992

Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.

musculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatmentKnee replacementDentistryIn Vitro TechniquesKnee JointProsthesis Designmedicine.disease_causeCondyleWeight-bearingWeight-BearingMotionCadavermedicineHumansOrthopedics and Sports MedicineFemurOrthodonticsbusiness.industryBone Cementsequipment and suppliesmusculoskeletal systemSagittal planesurgical procedures operativemedicine.anatomical_structureOrthopedic surgerySurgeryKnee ProsthesisbusinessCadaveric spasmInternational Orthopaedics
researchProduct

A “Painful Tic Convulsif” (Trigeminal Neuralgia And Ipsilateral Facial Spasm) Due To Double Neuro-Vascular Impingement: A Case Report.

2011

painful tic convulsif trigeminal neuralgia facial spasm neurovascular impingement
researchProduct

Intracranial Venous Alteration in Patients With Aneurysmal Subarachnoid Hemorrhage: Protocol for the Prospective and Observational SAH Multicenter St…

2022

BackgroundArterial vasospasm has been ascribed as the responsible etiology of delayed cerebral infarction in patients with aneurysmal subarachnoid hemorrhage (aSAH), but other neurovascular structures may be involved. We present the protocol for a multicenter, prospective, observational study focused on analyzing morphological changes in cerebral veins of patients with aSAH.Methods and AnalysisIn a retrospective arm, we will collect head arterial and venous CT angiograms (CTA) of 50 patients with aSAH and 50 matching healthy controls at days 0–2 and 7–10, comparing morphological venous changes. A multicenter prospective observational study will follow. Patients aged ≥18 years of any gender …

surgical clipping10180 Clinic for Neurosurgerybrain circulationSettore MED/36endovascular coilingsubarachnoid hemorrhage610 Medicine & healthSurgerybrain aneurysmvenous alterationvasospasm
researchProduct

Redzes asuma treniņu efektivitāte

2018

Bakalaura darbs ir uzrakstīts angļu valodā uz 27. lappasspusēm, satur 12 attēlus, 1. tabulu un tajā ir atsauksmes uz 21. literatūras avotu. Darba mērķis ir novērtēt redzes asumu uzlabojošo treniņu efektivitāti. Viens no iemesliem pazeminātai redzei var būt palielināta tuvuma slodze, kā arī pazeminātas spējas veikt dažādus vizuālos uzdevumus. Trenējot šīs spējas, redzes sistēma labāk pielāgojas palielinātai tuvuma slodzei. Pētījumā piedalījās 24 bērni, kuriem tika doti dažādi redzes treniņi 3 mēnešu periodā. Redzes asums treniņu beigās būtiski uzlabojās (p<0.0001), salīdzinot ar treniņu sākumu. Vidējais uzlabojums bija 0,19 logMAR vienības. Dalībniekiem ar miopiju ametropijas lielums treniņu…

visual acuityvisual trainingaccommodative spasmvisual stressOptometrija
researchProduct

Chemical composition and biological activity of the essential oil of Ballota hispanica (L.) Benth. growing wild in Sicily

2015

Ballota L. comprises several relevant species largely used for their excellent therapeutic properties. Ballota hispanica (L.) Benth. is widely used in herbal medicine, and it is sold in herbalist shops for its sedative and antispasmodic properties. Considering its traditional medicinal use and the lack of scientific studies on the volatile components of this species as well as on its biological activities, in this study the chemical composition of the essential oil from aerial parts of B. hispanica, collected in Sicily, was evaluated by gas chromatography and gas chromatography–mass spectrometry. α-Elemol was the most abundant component of the oil (10.9%), followed by α-ylangene (8.5%),…

α-elemolPlant Sciencefree radical scavenging activityBiology01 natural scienceslaw.inventionlawBotanymedicineMedicinal plantsChemical compositionEcology Evolution Behavior and SystematicsEssential oilantimicrobial activity010405 organic chemistryBiological activityAntimicrobialbiology.organism_classificationEcology Evolution Behavior and Systematic0104 chemical sciences010404 medicinal & biomolecular chemistryBallota hispanicaα-ylangeneComposition (visual arts)AntispasmodicBallotamedicine.drugPlant Biosystems - An International Journal Dealing with all Aspects of Plant Biology
researchProduct