Search results for "Spatial resolution"
showing 10 items of 51 documents
An assessment of the differences between spatial resolution and grid size for the SMAP enhanced soil moisture product over homogeneous sites
2018
Abstract Satellite-based passive microwave remote sensing typically involves a scanning antenna that makes measurements at irregularly spaced locations. These locations can change on a day to day basis. Soil moisture products derived from satellite-based passive microwave remote sensing are usually resampled to a fixed Earth grid that facilitates their use in applications. In many cases the grid size is finer than the actual spatial resolution of the observation, and often this difference is not well understood by the user. Here, this issue was examined for the Soil Moisture Active Passive (SMAP) enhanced version of the passive-based soil moisture product, which has a grid size of 9-km and …
Active shape correction of a thin glass/plastic x-ray mirror
2015
Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or plastic in order to keep the total mass within acceptable limits. Optics based on thin slumped glass foils are currently in use in the NuSTAR telescope and are being developed at various institutes like INAF/OAB, aiming at improving the angular resolution to a few arcsec HEW. Another possibility would be the use of thin plastic foils, being developed at SAO and the Palermo University. Even if relevant progresses in the achieved angular resolution were recently made, a viable possibility to further improve the mirror figure would be the app…
MR-Perfusionsbildgebung des Herzens mit TrueFISP
2001
OBJECTIVE Development and test of a saturation-recovery TrueFISP (SR-Trufi) pulse sequence for myocardial perfusion MR imaging (MRI) using improved gradient hardware. MATERIAL AND METHODS Measurements were performed on a 1.5 T scanner with prototype gradients (50 mT/m, minimum rise time 300 microseconds). T1-weighted first-pass MRI of Gd-DTPA (0.025 mumol/kg) kinetics in the myocardium was performed using an SR-Trufi pulse sequence (TR/TE/alpha = 2.6 ms/1.4 ms/55 degrees) with a saturation preparation of TD = 30 ms before the TrueFISP readout. Measurements were performed in volunteers (n = 4) and in a pig model of chronic ischemia (n = 1). RESULTS In phantoms, the signal intensity was linea…
A Time Projection Chamber with GEM-Based Readout
2016
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
Radiation hard monolithic CMOS sensors with small electrodes for High Luminosity LHC
2019
Abstract The upgrade of the tracking detectors for the High Luminosity-LHC (HL-LHC) requires the development of novel radiation hard silicon sensors. The development of Depleted Monolithic Active Pixel Sensors targets the replacement of hybrid pixel detectors with radiation hard monolithic CMOS sensors. We designed, manufactured and tested radiation hard monolithic CMOS sensors in the TowerJazz 180 nm CMOS imaging technology with small electrodes pixel designs. These designs can achieve pixel pitches well below current hybrid pixel sensors (typically 50 × 50 μ m ) for improved spatial resolution. Monolithic sensors in our design allow to reduce multiple scattering by thinning to a total si…
A CZT 3D imaging spectrometer prototype with digital readout for high energy astronomy
2023
The scientific challenges still open in hard X-rays and γ-rays astronomy require the development of new instrumentation able to overcome the sensitivity limits of the present one. Among the technologies currently under study to cover the energy range between several tens of keV and one MeV, the development of telescopes equipped with broadband Laue lenses associated with focal planes with high spectroscopic and imaging performance represents an extremely promising solution. With this perspective, we report on the development and the first spectroscopic characterisation results of an X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimension…
Monitoring of cortical blood flow: Clinical relevance of experimental laser Doppler studies
1996
Continuous monitoring of cortical blood flow provides real time information of CBF-changes during neurosurgical operations and on the neurointensive care unit. Laser Doppler flowmetry is a continuous, noninvasive technique suitable for measurement of the cortical microcirculation. In a number of experimental studies we have analyzed the characteristics of this method for cortical blood flow monitoring. The high spatial resolution of laser Doppler flowmetry and the heterogeneity of the cortical microvascular network results in a scatter of flow values over a wide range depending on the site of measurement. Data collection from different spots and calculation of frequency histogram may serve …
Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector
2018
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z|= 3.5 m and covering the region 2.4 <|η|< 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3×1.3 mm2 and arrays with 2×2 pads with a surface area of 2×2 mm2 or 3×3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SP…
Deceleration in the Expansion of SN 1993J
1997
A rarity among supernova, SN 1993J in M81 can be studied with high spatial resolution. Its radio power and distance permit VLBI observations to monitor the expansion of its angular structure. This radio structure was previously revealed to be shell-like and to be undergoing a self-similar expansion at a constant rate. From VLBI observations at the wavelengths of 3.6 and 6 cm in the period 6 to 42 months after explosion, we have discovered that the expansion is decelerating. Our measurement of this deceleration yields estimates of the density profiles of the supernova ejecta and circumstellar material in standard supernova explosion models.
Nanoscale inhomogeneity of the Schottky barrier and resistivity inMoS2multilayers
2015
Conductive atomic force microscopy (CAFM) is employed to investigate the current injection from a nanometric contact (a Pt coated tip) to the surface of ${\text{MoS}}_{2}$ thin films. The analysis of local current-voltage characteristics on a large array of tip positions provides high spatial resolution information on the lateral homogeneity of the $\mathrm{tip}/{\text{MoS}}_{2}$ Schottky barrier ${\mathrm{\ensuremath{\Phi}}}_{B}$ and ideality factor $n$, and on the local resistivity ${\ensuremath{\rho}}_{\text{loc}}$ of the ${\text{MoS}}_{2}$ region under the tip. Here, ${\mathrm{\ensuremath{\Phi}}}_{B}=300\ifmmode\pm\else\textpm\fi{}24\phantom{\rule{0.28em}{0ex}}\text{meV}, n=1.60\ifmmode…