Search results for "Speckle pattern"
showing 10 items of 83 documents
IS A 3D SPECKLE TRACKING ALGORITHM SYNONYMOUS WITH BETTER ESTIMATION OF LEFT VENTRICULAR FUNCTION?
2012
Multi-speckle autocorrelation spectroscopy — a new strategy to monitor ultraslow dynamics in dense and nonergodic media
2007
We present a modification of the conventional dynamic light scattering set-up which allows to monitor the intensity fluctuations of many independent spatial Fourier components of the density fluctuations, i.e. “speckles”, simultaneously by using a charge-coupled device (CCD) camera as area detector. By averaging over the intensity autocorrelation function the final 10–20% decay of the intermediate scattering function in very dense colloidal dispersions is obtained with much higher accuracy. At the same time this multi-speckle autocorrelation spectroscopy provides an alternative route for constructing ensemble-averaged intermediate scattering functions in nonergodic media by replacing the av…
Surpassing digital holography limits by lensless object scanning holography.
2012
We present lensless object scanning holography (LOSH) as a fully lensless method, capable of improving image quality in reflective digital Fourier holography, by means of an extremely simplified experimental setup. LOSH is based on the recording and digital post-processing of a set of digital lensless holograms and results in a synthetic image with improved resolution, field of view (FOV), signal-to-noise ratio (SNR), and depth of field (DOF). The superresolution (SR) effect arises from the generation of a synthetic aperture (SA) based on the linear movement of the inspected object. The same scanning principle enlarges the object FOV. SNR enhancement is achieved by speckle suppression and c…
Synthetic aperture superresolution by speckle pattern projection.
2009
We propose a method for increasing the resolution of an aperture limited optical system by illuminating the input with a speckle pattern. The high resolution of the projected speckle pattern demodulates the high frequencies of the sample and permits its passage through the system aperture. A decoding provides the superresolved image. The speckle pattern can be generated in a simple manner in contrast with other structured light superresolution methods. The method is demonstrated in microscopy test images.
Speckle based configuration for simultaneousin vitroinspection of mechanical contractions of cardiac myocyte cells
2013
In this manuscript we propose optical lensless configuration for a remote non-contact measuring of mechanical contractions of vast number of cardiac myocytes. All the myocytes were taken from rats, and the measurements were done in an in vitro mode. The optical method is based on temporal analysis of secondary reflected speckle patterns generated in lensless microscope configuration. The processing involves analyzing the movement and the change in the statistics of the generated secondary speckle patterns that are created on top of the cell culture when it is illuminated by a spot of laser beam. The main advantage of the proposed system is the ability to measure many cells simultaneously (a…
Optical sensor for remote estimation of alcohol concentration in blood stream
2013
Abstract The purpose of this manuscript is to validate our recently developed novel optical approach for extraction of remote vibration sources as a successful technique to estimate the alcohol concentration in blood stream. This technique is based on the tracking of temporal changes of reflected secondary speckle patterns produced in human skin when being illuminated by a laser beam. Since the skin’s vibrations profile is changed due to the alcohol in the blood stream, the extraction of the vibration profile can be translated into the corresponding alcohol concentration values by means of defining several parameters acting as indicators for the presence of alcohol in the blood stream. We h…
Depth sensing using coherence mapping
2010
A method for depth sensing based on sensing the visibility associated with the coherence function of a laser source is presented. The setup is based on an electronic speckle pattern interferometric (ESPI) setup, where the object depth is encoded into the amplitude of the interference pattern without the need for depth scanning. After performing phase-shifting method, the object three-dimensional (3-D) shape is reconstructed by means as a range image from the visibility of the image set of interferograms and where each gray level represents a given object depth. Experimental results validate the proposed approach for reflective diffuse objects at different measurement distances.
Hybrid optical-digital method for local-displacement analysis by use of a phase-space representation.
2010
A method for evaluating the local deformation or displacement of an object in speckle metrology is described. The local displacements of the object in one direction are digitally coded in a one-dimensional specklegram. By optically performing the local spectrum of this pattern, one simultaneously achieves information about the local displacement and its spatial position. The good performance of this technique is demonstrated with computer-generated test signals.
Classification of SD-OCT Volumes Using Local Binary Patterns: Experimental Validation for DME Detection
2016
International audience; This paper addresses the problem of automatic classification of Spectral Domain OCT (SD-OCT) data for automatic identification of patients with Diabetic Macular Edema (DME) versus normal subjects. Optical Coherence Tomography (OCT) has been a valuable diagnostic tool for DME, which is among the most common causes of irreversible vision loss in individuals with diabetes. Here, a classification framework with five distinctive steps is proposed and we present an extensive study of each step. Our method considers combination of various pre-processings in conjunction with Local Binary Patterns (LBP) features and different mapping strategies. Using linear and non-linear cl…
Speckle tracking analysis in intensive care unit: A toy or a tool?
2018
The use of conventional echocardiography in the intensive care unit (ICU) is today established to assess left and right ventricular systolic function, for preload determination and procedural guidance. Next step in ICU echocardiography could be the use of novel ultrasound techniques such as strain echocardiography to assist in the management of patients with acute coronary syndrome, heart failure, or pulmonary embolism. This review has gathered the available evidence supporting the incremental value of strain in the diagnostic workup of cardiac diseases treated in ICU.