Search results for "Spectrometer"

showing 10 items of 751 documents

EXAFS and XANES Studies of CoxMg1−xO Solid Solutions Using a Laboratory EXAFS Spectrometer

1993

Studies of the local electronic structure and the short-range order in solid solutions CoxMg1−xO with x varying from 0.02 to 1.00 are carried out on the CoK-edge X-ray absorption spectra using a laboratory EXAFS spectrometer. A non-monotonous change of the CoO distance in the first coordination shell with a bent at about x = 0.5 is established. The second coordination shell of cobalt is formed by cobalt and magnesium atoms with a distribution close to a statistical one. [Russian Text Ignored.]

Absorption spectroscopySpectrometerExtended X-ray absorption fine structureInorganic chemistryAnalytical chemistrychemistry.chemical_elementElectronic structureCondensed Matter PhysicsXANESElectronic Optical and Magnetic MaterialsBond lengthchemistryCobaltSolid solutionPhysica Status Solidi (a)
researchProduct

Multi-mycotoxin analysis in wheat semolina using an acetonitrile-based extraction procedure and gas chromatography–tandem mass spectrometry

2012

A new analytical method for the rapid and simultaneous determination of ten mycotoxins including patulin, zearalenone and eight trichothecenes (nivalenol, fusarenon-X, diacetoxyscirpenol, 3-acetyl-deoxynivalenol, neosolaniol, deoxynivalenol, T-2 and HT-2) in wheat semolina has been developed and optimized. Sample extraction and purification were performed with a modified QuEChERS-based (acronym of Quick, Easy, Cheap, Effective, Rugged and Safe) procedure and determined by gas chromatography (GC) coupled to triple quadrupole instrument (QqQ). This is the first paper on the application of GC-QqQ-MS/MS to analysis of mycotoxins. Careful optimization of the gas chromatography-tandem mass spectr…

AcetonitrilesChromatographyGas Chromatography/Tandem Mass SpectrometryCalibration curveFlourLiquid-Liquid ExtractionOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineHydrogen-Ion ConcentrationMycotoxinsQuechersSensitivity and SpecificityBiochemistryGas Chromatography-Mass SpectrometryDiacetoxyscirpenolAnalytical ChemistryTriple quadrupole mass spectrometerPatulinchemistry.chemical_compoundchemistryTandem Mass SpectrometryGas chromatographyGas chromatography–mass spectrometryJournal of Chromatography A
researchProduct

Spectral Transmission of the Human Crystalline Lens in Adult and Elderly Persons: Color and Total Transmission of Visible Light

2012

Purpose To experimentally measure the spectral transmission of human crystalline lenses belonging to adult and elderly persons, and to determine the color and total transmission of visible light of such crystalline lenses. Methods The spectral transmission curve of 32 human crystalline lenses was measured using a PerkinElmer 800UV/VIS spectrometer. Total transmission of visible light and the chromatic coordinates of these crystalline lenses were determined from these curves for solar illumination. Results The crystalline lens that filters UV and its transmission in the visible spectrum decreases with age; such a decrease is greater for short wavelengths. The total transmission of visible li…

AdultMaleAgingMaterials scienceUltraviolet RaysColorMineralogylaw.inventionOpticsElderly personslawLens CrystallineTransmittanceHumansChromatic scaleAgedSunlightSpectrometerbusiness.industrySpectrum AnalysisMiddle Agedeye diseasesLens (optics)WavelengthSunlightFemalesense organsbusinessPhotic StimulationVisible spectrumInvestigative Opthalmology & Visual Science
researchProduct

Spectral transmission of the pig lens: Effect of ultraviolet A+B radiation

2014

Summary Objective To determine the spectral transmission curve of the crystalline lens of the pig. To analyse how this curve changes when the crystalline lens is irradiated with ultraviolet A + B radiation similar to that of the sun. To compare these results with literature data from the human crystalline lens. Procedures We used crystalline lenses of the common pig from a slaughterhouse, i.e. genetically similar pigs, fed with the same diet, and slaughtered at six months old. Spectral transmission was measured with a Perkin-Elmer Lambda 35 UV/VIS spectrometer. The lenses were irradiated using an Asahi Spectra Lax-C100 ultraviolet source, which made it possible to select the spectral emissi…

AdultMaterials scienceAnterior subcapsular cataractLightSwineUltraviolet RaysRadiationmedicine.disease_causeCataractSpectral linelaw.inventionOpticslawLens CrystallinemedicineAnimalsHumansScattering RadiationIrradiationSpectrometerbusiness.industrySpectrum Analysiseye diseasesLens (optics)OphthalmologyChild Preschoolsense organsbusinessUltravioletVisible spectrumJournal Français d'Ophtalmologie
researchProduct

Effective broadband refractive index retrieval by a white light optical particle counter.

2009

A new approach to retrieve the effective broadband refractive indices (nbroad,eff) of aerosol particles by a white light aerosol spectrometer (WELAS) optical particle counter (OPC) is presented. Using a tandem differential mobility analyzer (DMA)-OPC system, the nbroad,eff are obtained for both laboratory and field applications. This method was tested in the laboratory using substances with a wide range of optical properties. With the obtained nbroad,eff, WELAS aerosol size distributions can be corrected. Therefore, this method can be used for instrument calibration in both laboratory and field measurements. The retrieved effective broadband refractive indices for the scattering aerosols we…

AerosolsSpectrometerLightScatteringChemistryAtmosphereSpectrum AnalysisAnalytical chemistryGeneral Physics and AstronomyAerosolPhotometryWavelengthRefractometryDifferential mobility analyzerCalibrationParticulate MatterGasesPhysical and Theoretical ChemistryParticle SizeParticle counterRefractive indexEnvironmental MonitoringPhysical chemistry chemical physics : PCCP
researchProduct

First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas

2014

The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…

AnalyteHydrogenAnalytical chemistrychemistry.chemical_elementOxygenAnalytical ChemistryTriple quadrupole mass spectrometerIonAmmoniachemistry.chemical_compoundchemistryIsobaric processInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…

2014

An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…

Analytical chemistryTandem mass spectrometryOrbitrapBiochemistryMass SpectrometryAnalytical Chemistrylaw.inventionMatrix (chemical analysis)Gel permeation chromatographychemistry.chemical_compoundColumn chromatographylawTandem Mass SpectrometryAnimalsMuscle SkeletalChromatography High Pressure LiquidHexabromocyclododecaneChromatographyEelsOrganic ChemistryFishesReproducibility of ResultsGeneral MedicineRepeatabilityTriple quadrupole mass spectrometerHydrocarbons BrominatedchemistryWater Pollutants ChemicalEnvironmental MonitoringJournal of chromatography. A
researchProduct

Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…

2015

A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…

Analytical chemistrychemistry.chemical_elementNatural GasMass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeLimit of DetectionEnvironmental ChemistryBenzeneSpectroscopyDetection limitAir PollutantsZeeman effectSpectrometerSpectrophotometry AtomicAbsorption RadiationBenzeneEquipment DesignTolueneMercury (element)WavelengthMercury IsotopeschemistrysymbolsEnvironmental MonitoringAnalytica chimica acta
researchProduct

A method for the surface reflectance retrieval from PROBA/CHRIS data over land: application to ESA SPARC campaigns

2005

The Compact High Resolution Imaging Spectrometer (CHRIS) onboard the Project for On-Board Autonomy (PROBA) platform system provides the first high spatial resolution hyper-spectral/multiangular remote sensing data from a satellite system, what represents a new source of information for Earth Observation purposes. A fully consistent radiative transfer approach is always preferred when dealing with the retrieval of surface reflectance from hyperspectral/multiangular data. However, due to the reported calibration anomalies for CHRIS data, a direct atmospheric correction based on physical radiative transfer modeling is not possible, and the method must somehow compensate for such calibration pr…

Ancillary dataEarth observationSpectrometerAtmospheric correctionRadiative transferCalibrationGeneral Earth and Planetary SciencesHyperspectral imagingEnvironmental science550 - Earth sciencesElectrical and Electronic EngineeringImage resolutionRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct

The cryogenic anticoincidence detector for ATHENA-XMS: preliminary results from the new prototype

2012

ATHENA has been the re-scoped IXO mission, and one of the foreseen focal plane instrument was the X-ray Microcalorimeter Spectrometer (XMS) working in the energy range 0.3-10 keV, which was a kilo-pixel array based on TES (Transition Edge Sensor) detectors. The need of an anticoincidence (AC) detector is legitimated by the results performed with GEANT4 simulations about the impact of the non x-ray background onto XMS at L2 orbit (REQ. < 0.02 cts/cm2/s/keV). Our consortium has both developed and tested several samples, with increasing area, in order to match the large area of the XMS (64 mm2). Here we show the preliminary results from the last prototype. The results achieved in this work off…

Anticoincidence detectorLow temperature DetectorAnticoincidence detectorsAstrophysicsOrbital mechanicslaw.inventionOpticslawElectronicOptical and Magnetic MaterialsElectrical and Electronic EngineeringAnticoincidence detectors; High Energy Astrophysics; Low temperature Detectors; TES; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic EngineeringPhysicsLow temperature DetectorsSpectrometerbusiness.industryApplied MathematicsElectronic Optical and Magnetic MaterialBolometerDetectorComputer Science Applications1707 Computer Vision and Pattern RecognitionCondensed Matter PhysicsApplied MathematicCardinal pointMillimeterSatelliteTransition edge sensorHigh Energy AstrophysicbusinessTESHigh Energy AstrophysicsSPIE Proceedings
researchProduct