Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer

2000

Abstract The masses of Xe isotopes with 124⩾ A ⩾114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm ≈12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found.

PhysicsNuclear and High Energy PhysicsSpectrometer[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]Physics::Instrumentation and Detectors010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometry01 natural sciencesISOLTRAPAtomic massIsotopes of oxygenNuclear physics0103 physical sciencesIsotopes of xenonAtomic physicsParticle PhysicsNuclear Experiment010306 general physicsQuadrupole mass analyzerHybrid mass spectrometer
researchProduct

A coded mask for γ-ray astronomy. Design and calibration

2003

Abstract The high-resolution γ-ray spectrometer (SPI) is one of the two main instruments on board the ESA INTEGRAL satellite successfully launched in October 2002. SPI uses coded aperture mask technique in order to have imaging capabilities at the energy band (20 keV–8 MeV) it will study celestial sources. The SPI imaging performance depends critically on the quality of the coded mask response and also on the precise knowledge of such response function. In this paper we present a general description of the SPI Coded Mask design together with its main features. Scientific impact of INTEGRAL SPI Coded Mask design on the instrument capabilities is also discussed. Results obtained for Mask cali…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsIntegrated circuit layoutOn boardOpticsQuality (physics)CalibrationSatelliteCoded aperturebusinessInstrumentationRemote sensingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Spectroscopic response of a CdZnTe multiple electrode detector

2007

Abstract The spectroscopic performances of a CdZnTe detector (crystal size: 5×5×0.9 mm 3 ) with five electrodes (cathode, anode and three steering electrodes) were studied. The anode layout, which consists of a circular electrode ( φ =80 μm) surrounded by two ring electrodes (gap=100 μm; radial width Δ r =100 μm) and by one electrode that extends to the edge of the crystal, is mostly sensitive to the electron carriers, overcoming the well known effect of the hole trapping in the measured spectra. We report on the spectroscopic response of the detector at different bias voltages of the electrodes and at various photon energies ( 109 Cd, 241 Am and 57 Co sources). The CdZnTe detector exhibits…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryCdZnTe detectorSteering electrodeDetectorMultiple electrode detectorElectronSmall pixel effectCathodeAnodelaw.inventionCrystalFull width at half maximumX-ray and gamma ray spectroscopylawElectrodeOptoelectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Frontend electronics for high-precision single photo-electron timing using FPGA-TDCs

2014

Abstract The next generation of high-luminosity experiments requires excellent particle identification detectors which calls for Imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better than 100 ps is required by the Barrel DIRC to disentangle the complicated patterns created on the image plane. R&D studies have been performed to provide a design based on the TRB3 readout using FPGA-TDCs with a precision better than 20 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and …

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorIntegrated circuitImage planelaw.inventionTime-to-digital converterApplication-specific integrated circuitlawElectronicsField-programmable gate arraybusinessInstrumentationComputer hardwareNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A CdTe position sensitive spectrometer for hard X- and soft γ-ray polarimetry

2002

Coded Imager and Polarimeter for High Energy Radiation (CIPHER) is a hard X- and soft gamma- ray spectroscopic and polarimetric coded mask telescope based on an array of Cadmium telluride microspectrometers. The position sensitive detector (PSD) will be arranged in 4 modules of 32 x 32 crystals, each of 2 x 2 mm(2) cross-section and 10 mm thickness giving a total active area of about 160 cm(2), operating over a wide energy range (similar to10 keV to 1 MeV). Each PSD module is obtained by aligning 32 linear arrays of micro-detectors each also containing the integrated analog front end electronics on a thin ceramic layer. The CIPHER instrument will be proposed for a balloon experiment, both i…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorPolarimetryPolarimeterCadmium telluride photovoltaicslaw.inventionTelescopeAnalog front-endOpticslawOptoelectronicsbusinessInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Experimental results from Al/p-CdTe/Pt X-ray detectors

2013

Abstract Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm 3 ). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at −25 °C under a bias voltage of −1000 V. The spectroscopic performance of the detectors at b…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorX-ray detectorBiasingPhoton countingFull width at half maximumElectric fieldOptoelectronicsCharge carrierbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The large-area micro-channel plate entrance detector of the heavy-ion magnetic spectrometer PRISMA

2005

This paper describes the entrance detector of the magnetic spectrometer PRISMA recently installed at Legnaro. The detector is based on rectangular (80 x 100 mm(2)) Micro-Channel Plates (MCP). It provides a fast time signal and its position-sensitive anode allows to extract the X and Y information. It exploits an electrostatic field for the acceleration of secondary electrons from a thin Carbon foil (similar or equal to 20 mu g/cm(2)) onto the MCP assembly. The electrons are guided by a parallel magnetic field. Good performances were obtained in the laboratory tests. The detector is presently installed at the entrance of PRISMA and gives resolutions <= 400 ps in time, and 1 mm in both X and …

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectordetectors for heavy ions ; micro-channel plates ; magnetic spectrometers ; low-energy heavy-ion reactionsParticle detectorSecondary electronsCharged particleMagnetic fieldNuclear physicsOpticsElectric fieldMicrochannel plate detectorbusinessInstrumentation
researchProduct

IN13 Backscattering Spectrometer at ILL: Looking for Motions in Biological Macromolecules and Organisms

2008

In 1998, three partner groups (the French institutions Institut de Biologie Structurale and the Leon Brillouin Laboratory and the Italian Istituto Nazionale per la Fisica della Materia, now merged with the Consiglio Nazionale delle Ricerche, INFM-CNR) applied to operate the thermal backscattering spectrometer IN13, at the Institut Laue Langevin, as a French-Italian Collaborative Research Group (CRG). The plan was to have access to a dedicated spectrometer in order to explore how far neutron scattering could contribute to the understanding of dynamics in biological macromolecules: how “flexible” must be a biological object to perform its function?

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryneutron scattering02 engineering and technologytechnique010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and Optics0104 chemical sciencesspectrometryOpticsinstrumentbiological physics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]0210 nano-technologybusinessComputingMilieux_MISCELLANEOUS
researchProduct

MONSTER: a TOF Spectrometer for beta-delayed Neutron Spectroscopy

2014

β-delayed neutron (DN) data, including emission probabilities, Pn, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

PhysicsNuclear and High Energy PhysicsSpectrometerta114Nuclear TheoryNeutron stimulated emission computed tomographyNeutron scatteringNeutron temperatureNeutron time-of-flight scatteringNeutron spectroscopyNuclear physicsNeutron cross sectionNeutronNuclear ExperimentNuclear Data Sheets
researchProduct

A high resolution electrostatic time-of-flight spectrometer with adiabatic magnetic collimation

1999

Abstract A new type of spectrometer for low energy charged particles is presented. It consists of an adiabatic magnetic collimation and two filters: an electrostatic retarding potential to set a lower limit (high pass) and a time-of-flight analysis to reject high energy charged particles (low pass). Both filters are only limited in their resolution by the efficiency of the adiabatic magnetic collimation. The proof of this principle is demonstrated by a pilot measurement on the K conversion line of 83mKr. Possible applications to pulsed and continuous electron sources are discussed with the emphasis on the investigation of the β spectrum of T2 to deduce information on the mass of the electro…

PhysicsNuclear and High Energy PhysicsTime of flightLuminosity (scattering theory)SpectrometerMeasuring instrumentContext (language use)ElectronAtomic physicsAdiabatic processInstrumentationCharged particleNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct