Field-portable Mössbauer spectroscopy on Earth, the Moon, Mars, and beyond

2011

ABSTRACT Iron occurs naturally as Fe 2+ , Fe 3+ , and, to a lesser extent, as Fe 0 . Many fundamental (bio)geochemical processes are based on redox cycling between these oxidation states. Mossbauer spectroscopy provides quantitative information about the distribution of Fe among its oxidation states, identification of Fe-bearing phases, and relative distribution of Fe among those phases. Portable, miniaturised Mossbauer spectrometers were developed for NASA9s Mars Exploration Rovers (in operation since 2004) and provide a means for non-destructive, in-situ field investigations. On Mars, these instruments provided evidence for aqueous activity with implications for habitability, were applied…

SpectrometerField (physics)MineralogyIn situ resource utilizationGeneral ChemistryMars Exploration ProgramExploration of MarsMeteoriteGeochemistry and PetrologyMössbauer spectroscopyGeneral Earth and Planetary SciencesGeologyEarth (classical element)General Environmental ScienceGeochemistry: Exploration, Environment, Analysis
researchProduct

Elastic neutron scattering of dry and rehydrated trehalose coated carboxy-myoglobin

2008

We report here a comparison between the hydrogen atoms mean square displacements measured by elastic neutron scattering on trehalose coated carboxy-myoglobin, at ILL on the backscattering spectrometers IN13 and IN16. An inconsistency is observed when comparing the mean square displacements measured on the two spectrometer, on samples of identical composition, since they resulted of larger amplitude on IN13 (either in condition of drought or after overnight rehydration under 75% D2O atmosphere), notwithstanding the lower time window accessible on this instrument with respect to IN16. Such inconsistency disappears when the data obtained on this last spectrometer are analyzed in two separate r…

SpectrometerHydrogenChemistryEnthalpyAnalytical chemistryPROTEINGeneral Physics and Astronomychemistry.chemical_elementNeutron scatteringMOLECULAR-DYNAMICS SIMULATIONTrehalosechemistry.chemical_compoundROOM-TEMPERATUREAmplitudeMyoglobinWATEREXTERNAL MATRIXWave vectorPhysical and Theoretical Chemistryneutron-scattering trehalose myoglobin
researchProduct

Laser-Induced Breakdown Spectroscopy for Rapid Elemental Analysis of Drillcore

2013

Abstract The elemental and mineralogical contents of rock drillcore can be analyzed using a variety of methods. For efficient exploration the characterization of the drillcore should be performed rapidly, so that the further drillings can be better planned and unnecessary costs can be reduced. In this paper, laser-induced breakdown spectroscopy (LIBS) is studied as a potential rapid on-line method for automated elemental analysis of drillcore. The method is based on a pulsed laser beam that transforms a small volume of the sample into plasma. Individual elements in the plasma have characteristic emission patterns detectable by a spectrometer. Based on the measured spectra the amount of diff…

SpectrometerInfraredElemental analysisChemistrySample (material)Analytical chemistryMineralogyHyperspectral imagingGeneral MedicineLaser-induced breakdown spectroscopySpectroscopyCharacterization (materials science)IFAC Proceedings Volumes
researchProduct

Coupled retrieval of aerosol optical thickness, columnar water vapor and surface reflectance maps from ENVISAT/MERIS data over land

2008

An algorithm for the derivation of atmospheric parameters and surface reflectance data from MEdium Resolution Imaging Specrometer Instrument (MERIS) on board ENVIronmental SATellite (ENVISAT) images has been developed. Geo-rectified aerosol optical thickness (AOT), columnar water vapor (CWV) and spectral surface reflectance maps are generated from MERIS Level-1b data over land. The algorithm has been implemented so that AOT, CWV and reflectance products are provided on an operational manner, making no use of ancillary parameters apart from those attached to MERIS products. For this reason, it has been named Self-Contained Atmospheric Parameters Estimation from MERIS data (SCAPE-M). The fund…

SpectrometerMeteorologyCorrelation coefficientAtmospheric correctionSoil ScienceGeology550 - Earth sciencesAERONETAerosolEnvironmental scienceSatelliteComputers in Earth SciencesImage resolutionWater vaporRemote sensing
researchProduct

Spectral calibration and atmospheric correction of ultra-fine spectral and spatial resolution remote sensing data. Application to CASI-1500 data

2007

Imaging spectrometers operating in the solar spectrum measure the upwelling reflected solar radiation, and are an important tool in the bio/geochemical characterization of the Earth system. Surface reflectance is usually the starting point for the retrieval of biophysical parameters from remote measurements. Reliable radiometric and spectral calibrations and accurate atmospheric correction are mandatory in the interpretation of the surface reflectance. A complete surface reflectance retrieval scheme specifically designed for ultra-fine spectral resolution (bandwidth from 10 to 2 nm) and spatial resolution (pixel size less than 10 m) imaging spectrometers is presented in this work. The asses…

Spectrometerbusiness.industryAtmospheric correctionSoil Science550 - Earth sciencesGeologyImaging spectroscopyOpticsCalibrationRadiative transferRadiometryEnvironmental scienceComputers in Earth SciencesSpectral resolutionbusinessImage resolutionRemote sensingRemote Sensing of Environment
researchProduct

Reduction of Convective Low-Frequency Noise in Thermal Lens Spectrometry

1990

The construction and optimization of a thermal lens spectrometer with coaxial pump/probe configuration is reported. The low-frequency noise of convective origin is studied in detail, and it is demonstrated that a horizontal slit, instead of a pinhole, can be used as a simple way of reducing the noise to a negligible level without losing sensitivity.

Spectrometerbusiness.industryChemistryInfrasound010401 analytical chemistry01 natural sciences0104 chemical scienceslaw.invention010309 opticsLens (optics)Opticslaw0103 physical sciencesThermalPinhole (optics)CoaxialbusinessInstrumentationImage resolutionSpectroscopyNoise (radio)Applied Spectroscopy
researchProduct

New sunphotometer for network operation.

1983

A handheld sunphotometer has been developed and is described. It operates for 9 wavelengths in the visible and near infrared. The sensitivity range is rather broad, so it can be used in turbid as well as clear atmospheres. The operation is simple, and a digital readout helps prevent operator biases. The instrument is sun powered and suitable for network operations. Determination of the atmospheric turbidity due to aerosol and the column content of O3, NO2, H2O is possible.

Spectrometerbusiness.industryStray lightMaterials Science (miscellaneous)Near-infrared spectroscopyNetwork operations centerIndustrial and Manufacturing EngineeringAerosolPhotometry (optics)WavelengthOpticsEnvironmental scienceBusiness and International ManagementbusinessNear infrared radiationRemote sensingApplied optics
researchProduct

Resonance ionization mass spectroscopy for trace determination of plutonium in environmental samples

1997

Resonance ionization mass spectroscopy (RIMS) is a sensitive and isotope selective method and well suited for trace analysis of plutonium in the environment. After the chemical isolation of plutonium from soil, air filters or urine, e.g., it is electrolytically deposited as hydroxide on a tantalum backing and covered with a thin titanium layer. By heating such a sandwich filament in the RIMS-apparatus under vacuum an atomic beam of plutonium is produced. The atoms are ionized by a three-step resonant excitation using pulsed dye lasers, and the ions are mass-selectively detected with a time-of-flight (TOF) spectrometer and a multi channel plate detector. RIMS yields a low detection limit of …

SpectrometerchemistryIonizationRadiochemistryAnalytical chemistryTantalumchemistry.chemical_elementPlutonium in the environmentMass spectrometryBiochemistryAir filterPlutoniumIonFresenius' Journal of Analytical Chemistry
researchProduct

Vicarious calibration of MERIS over dark waters in the near infrared

2005

Abstract We propose to evaluate the calibration of MERIS (MEdium Resolution Imaging Spectrometer) over dark waters in the near infrared. We work with 5 months of data, from July to November 2003, over five world sites: Venice and Lampedusa in Italy, El Arenosillo in Spain, MOBY/Lanai and CalCOFI/San Nicolas in the United States. The sites are all equipped with a CIMEL station that forms part of the AERONET network. The basic idea is to associate CIMEL sky radiance measurements with MERIS level-1b data in a twin geometry which corresponds to the same scattering angle. This vicarious calibration relies on an accurate description of the atmospheric scattering based on the CIMEL measurements. A…

Spectrometermedia_common.quotation_subjectNear-infrared spectroscopyImaging spectrometerDiffuse sky radiationSoil ScienceGeologyAERONET[SDE.MCG] Environmental Sciences/Global Changes[ SDE.MCG ] Environmental Sciences/Global Changes[SDU.STU.CL] Sciences of the Universe [physics]/Earth Sciences/ClimatologySkyCalibrationRadianceEnvironmental scienceComputers in Earth Sciences[ SDU.STU.CL ] Sciences of the Universe [physics]/Earth Sciences/ClimatologyRemote sensingmedia_common
researchProduct

Routine application using single quadrupole liquid chromatography-mass spectrometry to pesticides analysis in citrus fruits.

2005

Abstract A rapid and sensitive liquid chromatography–electrospray ionization–mass spectrometry method has been developed for the routine analysis of buprofezin, bupirimate, hexaflumuron, tebufenpyrad, fluvalinate and pyriproxyfen in citrus fruits. Extracts were obtained by matrix solid-phase dispersion (MSPD) using C 18 as dispersant and dichloromethane-methanol (80:20, v/v) as eluent. Matrix effects were tested for all matrices by addition of standard to sample blank extracts (samples containing no detectable residues). Mean recoveries obtained at fortification levels between 0.01 and 5 mg kg −1 were 57–97% with relative standard deviations (RSDs) from 5 to 19%. The limits of quantificatio…

Spectrometry Mass Electrospray IonizationChromatographyChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryTriple quadrupole mass spectrometerMatrix (chemical analysis)Liquid chromatography–mass spectrometryFruitmedia_common.cataloged_instanceSample preparationSolid phase extractionEuropean unionPesticidesmedia_commonChromatography LiquidJournal of chromatography. A
researchProduct