Search results for "Spectroscopy"
showing 10 items of 10293 documents
Analysis of phytosterols in foods
2006
Phytosterols are bioactive compounds, one of their most studied and outstanding properties being their cholesterol-lowering activity. This explains the growing interest in the phytosterol contents of foods as either intrinsic or added components. The different steps (extraction, saponification, clean up, chromatographic determination) of plant sterol determination are reviewed, and emphasis is placed on the methods used to assay different phytosterols in food.
Rayleigh and Brillouin scattering in a lysozyme–water mixture: An unusual behavior around 343K
2011
Abstract This article describes Rayleigh and Brillouin light scattering studies on a lysozyme–water mixture from 293 K to 355 K. The scattering intensities from this system are compared with those from a sodium acetate buffer used to dissolve the lysozyme. It is found that in the vicinity of 343 K the lysozyme–water mixture becomes opalescent, and the intensity of the Brillouin peaks decreases and almost vanishes, to be restored at temperatures above 343 K. Around the same temperature the intensity of the central, unshifted Rayleigh peak, however, increases strongly. No such behavior was observed for the sodium acetate buffer. The analysis of the experimental data indicates an irreversible …
SilicaROD™ — A new challenge in fast high-performance liquid chromatography separations
1998
Abstract High performance liquid chromatography (HPLC) has become one of the most used methods for the analysis of compound mixtures in industry, especially for the quality control of products. Nowadays productivity is the major and dominant upcoming issue, i.e. the goal is to drastically reduce the analysis time and cost per analysis. The solution of the task is higher throughput and faster HPLC methods. Here we describe a new monolithic type of HPLC column, the SilicaROD™ column, which permits the fast HPLC separation of compound mixtures within a few minutes.
Size Exclusion Chromatography for Semipreparative Scale Separation of Au 38 (SR) 24 and Au 40 (SR) 24 and Larger Clusters
2011
Size exclusion chromatography (SEC) on a semipreparative scale (10 mg and more) was used to size-select ultrasmall gold nanoclusters (2 nm) from polydisperse mixtures. In particular, the ubiquitous byproducts of the etching process toward Au(38)(SR)(24) (SR, thiolate) clusters were separated and gained in high monodispersity (based on mass spectrometry). The isolated fractions were characterized by UV-vis spectroscopy, MALDI mass spectrometry, HPLC, and electron microscopy. Most notably, the separation of Au(38)(SR)(24) and Au(40)(SR)(24) clusters is demonstrated.
Accurate determination of element species by on-line coupling of chromatographic systems with ICP-MS using isotope dilution technique
1998
Abstract The instrumental design for coupling different liquid chromatographic systems such as ion, reversed phase, and size exclusion chromatography as well as capillary gas chromatography, with ICP-MS for the determination of element species is described. For accurate analyses obtaining ‘real time’ concentrations of chromatographic peaks, the isotope dilution mass spectrometric (IDMS) technique is applied. Two different spiking modes are possible, one using species-specific and another one using species-unspecific spike solutions of isotope-enriched labelled compounds. The species-specific mode is only possible for element species well defined in their structure and composition, for examp…
Identification and determination of amphetamine and methamphetamine in street drugs
2000
Abstract A procedure to identify and quantify amphetamine and/or methamphetamine in street drugs is proposed. The procedure is based on the application of the ACC method (Apparent content curves method) to emission and absorption data of samples. Discrimination and quantification of amphetamine and methamphetamine in samples is carried out based on their different behavior in acid and basic medium. Potential interfering drugs are tested and the accuracy of the method is verified in prepared and real samples. Results obtained are in agreement with a HPLC procedure used as reference.
Gibbs' Dividing Surface between a Fixed-Charge Membrane and an Electrolyte Solution. Application to Electrokinetic Phenomena in Charged Pores
1999
The Gibbs model for the boundary between two phases consists of replacing the finite interfacial region, where the properties of the system change gradually, by a dividing surface which acts as a third phase of zero volume in which some magnitudes change abruptly. This thermodynamic concept was recently applied to a planar interface between a fixed charge membrane and an electrolyte solution.1 The continuous decrease of counterions with the distance from the charged surface is replaced by a step function, so that the diffuse double layer is ideally represented by a charged region depleted of all co-ions. Here the cylindrical geometry is analyzed, and the planar case is revisited by proposin…
Determination of α-Tocopherol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection and Stability of α-Tocopherol under Dif…
2011
In order to study the clinical effects of the antioxidant alpha-tocopherol (tocofersolan, CAS 30999-06-5) a simple, robust, sensitive and reliable high performance liquid chromatography (HPLC) method using fluorescence detection for the daily measurement of alpha-tocopherol concentration in plasma is described. Several methods of HPLC analysis using fluorescence techniques are published, however, investigations of the stability of alpha-tocopherol during sample preparation under different conditions are relevant in the routine measurements and have to date not been reported. Therefore a modified method, both sensitive and robust, qualified for the day-by-day measurement of alpha-tocopherol …
Sunscreen analysis
2005
Although there are no official analytical methods for UV filters determination in sunscreen cosmetics, their maximum content are regulated by legislation, and then analytical methods to control these products are necessary. In this paper, analytical methods for UV filters determination in cosmetics, which can be found in the literature, are reviewed. The usefulness of the analytical methods, techniques and sample preparation is discussed. The analytical methods used for the determination of UV filters in other type of samples are commented upon. Moreover, a brief overview of the European Union legislation concerning UV filters is included.
Molecular connectivity as a relevant new tool for predicting analytical behavior: A survey of chemiluminescence and chromatography
2005
Abstract We present a critical presentation and discussion on molecular connectivity applied to analytical fields, giving special attention to predicting the chemiluminescent behavior of pharmaceuticals and pesticides. Molecular connectivity has been largely applied to predict the therapeutic effects of pharmaceuticals and rarely to predictions in analytical chemistry – basically to chromatographic processes and recently to liquid-phase chemiluminescence.