Search results for "Spectroscopy"

showing 10 items of 10293 documents

Comparison of silica-based materials for organophosphorus pesticides sampling and occupational risk assessment.

2020

Abstract A novel air sampler has been designed containing a sorbent based on UVM-7 mesoporous silica doped with Ti. The sorbent has been applied for the determination of organophosphorus pesticides in occupational air, followed by gas chromatography with mass spectrometry detection. Thus, several silica materials with different structures (mesoporous UVM-7 and microporous xerogels) were synthesized, and modified with the addition of Ti and Fe. The structure of these materials was proved by transmission electronic microscopy, energy-dispersive X-ray, X-ray diffraction, nitrogen adsorption-desorption and UV–Vis and Raman spectroscopy. The potential of these materials for the retention of pest…

AnalyteSorbentChromatographyChemistry010401 analytical chemistrySorption02 engineering and technologyMicroporous materialMesoporous silica021001 nanoscience & nanotechnologyMass spectrometry01 natural sciencesBiochemistry0104 chemical sciencesAnalytical ChemistryEnvironmental ChemistryGas chromatography0210 nano-technologyMesoporous materialSpectroscopyAnalytica chimica acta
researchProduct

A solid colorimetric sensor for the analysis of amphetamine-like street samples.

2016

A solid sensor obtained by embedding 1,2-naphthoquinone-4-sulfonate (NQS) into polydimethylsiloxane/tetraethylortosilicate/silicon dioxide nanoparticles composite has been developed to identify and determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxymetamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA). The analytes are derivatized inside the composite for 10 min to create a colored product which can be then quantified by measuring the diffuse reflectance or the color intensity after processing the digitalized image. Satisfactory limits of detection (0.002–0.005 g mL−1) and relative standard deviations (<10%) have been achieved. The proposed kit has been successfu…

AnalyteSpectrophotometry InfraredStreet drugsAnalytical chemistryNQS02 engineering and technology01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundColorimetric sensormedicineEnvironmental ChemistryAmphetamineSpectroscopyDetection limitPolydimethylsiloxaneIllicit Drugs010401 analytical chemistryAmphetaminesColor intensity021001 nanoscience & nanotechnology0104 chemical scienceschemistryColorimetrySpectrophotometry Ultraviolet0210 nano-technologymedicine.drugAnalytica chimica acta
researchProduct

Hyperbolic subtraction method: Determination of the concentration of an analyte in the presence of an unknown interferent via spectral data.

2018

A theoretical model to determine the concentration of an analyte in the presence of unknown interferents using spectral-type data is described. The method involves absorbance measurements at three wavelengths and the calculation of specific absorbances yielding a hyperbolic relationship between absorbance ratios and analyte concentrations. The concentration of the analyte of known spectrum can be determined in the presence of an interferent or mixture of interferents of unknown concentration(s) and spectra can be determined combining data for different sets of wavelengths. Application to indigo and isatin solutions in DMSO related to the so-called Maya blue problem is reported as an illustr…

AnalyteSubtraction methodChemistryIsatinAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and OpticsSpectral lineIndigo0104 chemical sciencesAnalytical ChemistryAbsorbancechemistry.chemical_compoundWavelength0210 nano-technologySpectroscopyInstrumentationSpectroscopySpectrochimica acta. Part A, Molecular and biomolecular spectroscopy
researchProduct

Determination of biochemical parameters in human serum by near-infrared spectroscopy

2014

NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipopr…

AnalyteVery low-density lipoproteinChromatographyMean squared errorChemistryCholesterolGeneral Chemical EngineeringNear-infrared spectroscopyGeneral EngineeringAnalytical chemistryAnalytical ChemistryAbsorbancechemistry.chemical_compoundPartial least squares regressionCalibrationAnalytical Methods
researchProduct

Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations

1998

The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…

Analytegenetic structuresResolution (mass spectrometry)ChemistrySample (material)Analytical chemistryPhysics::OpticsBiochemistrySpectral lineAnalytical ChemistryChemometricsAbsorbanceWavelengthStandard additionElectrochemistryEnvironmental Chemistrysense organsSpectroscopyThe Analyst
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct

Headspace–mass spectrometry determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers in soil samples using chemometrics

2007

A simple and fast method has been developed for the determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers (BTEX) in soils. Samples were introduced in 10 mL standard glass vials of a headspace (HS) autosampler together with 150 microL of 2,6,10,14-tetramethylpentadecane, heated at 90 degrees C for 10 min and introduced in the mass spectrometer by using a transfer line heated at 250 degrees C as interface. The volatile fraction of samples was directly introduced into the source of the mass spectrometer which was scanned from m/z 75 to 110. A partial least squares (PLS) multivariate calibration approach based on a classical 3(3) calibration model was build with m…

Analytical chemistryBTEXXylenesMass spectrometryBiochemistryEthylbenzeneGas Chromatography-Mass SpectrometryMass SpectrometryAnalytical ChemistryChemometricsSoilchemistry.chemical_compoundIsomerismBenzene DerivativesEnvironmental ChemistryBenzeneSpectroscopyChromatographyChromatographyXyleneTemperatureBenzeneTolueneHydrocarbonsBiodegradation EnvironmentalModels ChemicalchemistryCalibrationGas chromatographyTolueneAnalytica Chimica Acta
researchProduct

Pressure-induced magnetic switching and linkage isomerism in K0.4Fe4[Cr(CN)6]2.8 x 16 H2O: X-ray absorption and magnetic circular dichroism studies.

2008

The effect of applied pressure on the magnetic properties of the Prussian blue analogue K0.4Fe4[Cr(CN)6]2.8 x 16 H2O (1) has been analyzed by dc and ac magnetic susceptibility measurements. Under ambient conditions, 1 orders ferromagnetically at a critical temperature (T(C)) of 18.5 K. Under application of pressure in the 0-1200 MPa range, the magnetization of the material decreases and its critical temperature shifts to lower temperatures, reaching T(C) = 7.5 K at 1200 MPa. Pressure-dependent Raman and Mossbauer spectroscopy measurements show that this striking behavior is due to the isomerization of some Cr(III)-C[triple bond]N-Fe(II) linkages to the Cr(III)-N[triple bond]C-Fe(II) form. A…

Analytical chemistryBiochemistryCatalysisMagnetizationsymbols.namesakeMagneticsColloid and Surface ChemistryIsomerismX-Ray DiffractionChromium CompoundsMössbauer spectroscopyTavernePressureLinkage isomerismCyanidesMagnetic circular dichroismChemistrySpectrum AnalysisX-RaysTemperatureWaterGeneral ChemistryMagnetic susceptibilityX-ray magnetic circular dichroismsymbolsDiamagnetismRaman spectroscopyCrystallizationIron CompoundsJournal of the American Chemical Society
researchProduct

New insights in the formation of silanol defects in silicalite-1 by water intrusion under high pressure.

2010

International audience; The "water-silicalite-1" system is known to act as a molecular spring. The successive intrusion-extrusion cycles of liquid water in small crystallites (6 × 3 × 0.5 μm(3)) of hydrophobic silicalite-1 were studied by volumetric and calorimetric techniques. The experiments displayed a decrease of the intrusion pressure between the first intrusion-extrusion cycle and the consecutive ones, whereas the extrusion pressures remained unchanged. However, neither XRD studies nor SEM observations revealed any structural and morphological modifications of silicalite-1 at the long-range order. Such a shift in the value of the intrusion pressure after the first water intrusion-extr…

Analytical chemistryGeneral Physics and AstronomyInfrared spectroscopy02 engineering and technologyCalorimetry010402 general chemistryMolecular sieve01 natural scienceschemistry.chemical_compoundX-Ray DiffractionSpectroscopy Fourier Transform InfraredPressure[SDV.BBM]Life Sciences [q-bio]/Biochemistry Molecular BiologyPhysical and Theoretical ChemistryFourier transform infrared spectroscopyZeoliteSilicatesWaterSilanes021001 nanoscience & nanotechnology0104 chemical sciencesSilanolchemistryChemical engineeringSiloxaneX-ray crystallographyZeolitesCrystallite0210 nano-technologyCrystallizationPhysical chemistry chemical physics : PCCP
researchProduct

First signals of electrochemically oxidized species of TTF and TMT-TTF : a study by in situ spectroelectrochemical FTIR and DFT calculations

2003

A first study by in situ FTIR spectroelectrochemistry of TTF and TTM-TTF has been undertaken. The oxidation, in this case, is caused only by electrochemistry, which constitutes a clear advantage over chemical oxidation since no side products are present in the solution. In this context, we obtained the signals of neutral, radical cation, and dication species of TTF and TTM-TTF. The experimental conditions were chosen in order to avoid the possible formation of π-dimer species and to obtain a satisfactory signal-to-noise ratio. A weak signal was detected for TTF and a stronger one for TTM-TTF. The changes induced by the oxidation process in the IR spectra of TTF and TTM-TTF have been analyze…

Analytical chemistryGeneral Physics and AstronomyInfrared spectroscopyContext (language use)02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyElectrochemistry01 natural sciencesFourier transform spectroscopy0104 chemical sciencesDicationchemistry.chemical_compoundRadical ionchemistryPhysical chemistryDensity functional theoryPhysical and Theoretical Chemistry0210 nano-technologyTetrathiafulvalene
researchProduct