Search results for "Spectrum analyzer"
showing 10 items of 35 documents
Optimization of a conversion electron Mössbauer spectroscopy gas flow He/CH4 proportional counter
1992
A new detector for CEMS has been built and optimized with respect to the statistical quality of spectra obtained. The optimization has been performed by measuring Mosbauer and pulse height spectra at in- and off-resonance. Single channel analyzer settings were calculated by a new optimization routine. A comparison of different detector designs has been performed using the statistical utility rate of spectra obtained from a stainless steel foil. A procedure for determining optimal operating parameters for ICEMS gas flow proportional counters is proposed.
Limitation of fourier transform photoelasticity: Influence of isoclinics
2000
The application of the Fourier transform to photoelasticity was used in the evaluation of the retardation using a carrier system of fringes. In photoelasticity, the light intensity from the analyzer in a circular polariscope depends on both the retardation (isochromatics) and the isoclinic parameter. The theoretical analysis shows that the angle between the principal stresses in the model and in the carrier system of fringes influences the evaluation of the retardation (isochromatics), as occurs when misaligned compensators (namely, Babinet) are used. As a consequence, this method may not be applied as a full-field technique, although the error is small if the angle between the principal st…
A Method Based on Amplitude Probability Density Representation for Sounding High Frequency Noise in Ionospheric Channels
2021
High Frequency (HF) communications efficiency require a precise characterization of the ionospheric channel’s noise. We present a rapid and accurate method to sound the HF ionospheric channels that enables tracing of the time-availability of the channel based on imposed electric field strength thresholds. The method makes use of the amplitude probability density implemented in a real-time spectrum analyzer. Sounding of 3, 10 and 20 kHz bandwidth channels in the 4.8 – 8.8 MHz range is exemplified and specific observations are presented.
A ten-fold divided total absorption Ge(Li) gamma-ray detector
1976
Abstract We have constructed a split-crystal total absorption Ge(Li) gamma-ray spectrometer and special logic electronics for rejecting Compton continuum in spectra. A 10 cm3 planar detector was divided into ten electrically separated detectors by grinding nine parallel slots on the n-surface of the detector. In operation both the n- and p-contacts are isolated from the ground. Using capacitive sharing, most of the released electrical charge is taken from the p-contact into an ordinary pulse amplifier line and analyzed. A small fraction of the charge collected at the n-strips is observed with voltage-sensitive FET-preamplifiers. The following logic electronics provides a gate pulse for the …
Simultaneous recording of true and random coincidences using a two-parameter analyzer system
1971
Abstract A description is given of a simple fast coincidence method which allows the simultaneous recording of coincidence and random coincidence spectra. The method is based on the properties of a standard two-parameter pulse-height analyzer system, and no special electronics is required.
Highly efficient multichannel spin-polarization detection.
2011
Since the original work by Mott, the low efficiency of electron spin polarimeters, remaining orders of magnitude behind optical polarimeters, has prohibited many fundamental experiments. Here we report a solution to this problem using a novel concept of multichannel spin-polarization analysis that provides a stunning increase in efficiency by 4 orders of magnitude. This improvement was demonstrated in a setup using a hemispherical electron energy analyzer. An imaging setup proved the principal capability of resolving more than ${10}^{5}$ data points in parallel.
Hydrogen sulfide measurements in air by passive/diffusive samplers and high-frequency analyzer: A critical comparison
2016
In this study, hydrogen sulfide (H2S) measurements in air carried out using (a) passive/diffusive samplers (Radiello® traps) and (b) a high-frequency (60 s) real-time analyzer (Thermo® 450i) were compared in order to evaluate advantages and limitations of the two techniques. Four different sites in urban environments (Florence, Italy) and two volcanic areas characterized by intense degassing of H2S-rich fluids (Campi Flegrei and Vulcano Island, Italy) were selected for such measurements. The concentrations of H2S generally varied over 5 orders of magnitude (from 101e103 mg/m3), the H2S values measured with the Radiello® traps (H2SR) being significantly higher than the average values measure…
Sensitivity of SHG-FROG for the characterization of ultrahigh-repetition-rate telecommunication laser sources
2004
International audience; We analyze experimentally the sensitivity of second-harmonic generation frequency-resolved optical gating (SHG-FROG) for the complete intensity and phase characterization of both a sinusoidal beat signal and a train of 1.3 ps pulses at a repetition rate of 160 GHz at 1550 nm. Using a commercially-available optical spectrum analyzer in the SHG-FROG set-up, incident pulses with energies of only 125 and 190 fJ, which correspond to the beat signal and the 1.3 ps pulse train, respectively, have been accurately characterized.
Chromatographic Air Analyzer Microsystem for the Selective and Sensitive Detection of Explosive-related Compounds
2014
Abstract The detection of explosives and explosive-related compounds is of major importance for the monitoring of explosive- contaminated sites. Current methods need to become cheaper and portable while maintaining a high sensitivity and selectivity level. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level in the presence of toluene and moisture.
Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer.
2009
Objective This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. Design and methods Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. Results The CMIA total %CV's were all < 8% and the Limit of Quantification (LOQ) was < 1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R ≥ 0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R ≥ 0.94 at…