Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure
2011
We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…
A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries
2018
© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…
European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement
2003
IntroductionOver the past 20 years or so, the accuracy of the conventional Riva-Rocci/Korotkoff technique of blood pressure measurement has been questioned and efforts have been made to improve the technique with automated devices. In the same period, recognition of the phenomenon of white-coat hype
Practice guidelines of the European Society of Hypertension for clinic, ambulatory and self blood pressure measurement.
2005
Introduction Blood pressuremeasurement is the basis for the diagnosis, management, treatment, epidemiology and research of hypertension, and the decisions affecting these aspects of hypertensionwill be influenced, for better or worse, by the accuracyofmeasurement.Anaccuratebloodpressure reading is a prerequisite, therefore, regardless of which technique is used, yet all too often the accuracy of measurement is taken for granted or ignored. This paper is a summary up-dated version of the recommendations published by the European Society of Hypertension (ESH) Working Group on Blood Pressure Monitoring for conventional (CBPM), ambulatory (ABPM) and self (SBPM) blood pressure measurement in 200…
Factores que influyen en la diferencia de medida de presión arterial entre el método auscultatorio y el oscilométrico
2006
Fundamento y objetivo El metodo auscultatorio mediante esfigmomanometro de mercurio esta siendo sustituido por otros metodos de medida de presion arterial, de los que el mas utilizado es el oscilometrico. Se analiza las posibles discrepancias de medida entre ambos metodos y los factores que influyen en ellas. Material y metodo Se obtuvieron medidas de presion arterial (PA) mediante esfigmomanometro de mercurio, con un monitor Spacelabs, en el mismo brazo y mediante un metodo secuencial. La relacion entre ambas medidas se analizo mediante los coeficientes de correlacion de Pearson y el metodo de Bland y Altman. Se calcularon las diferencias entre ambos metodos de medida. Se analizo los facto…
Presión arterial: ¿esfigmomanómetro manual o digital?
2008
El presente es un estudio prospectivo y comparativo entre la medición de la presión arterial obtenida de manera manual con esfigmomanómetro aneroide y la obtenida mediante monitor automático. El desarrollo de la práctica se realizó sobre un grupo de 100 pacientes hospitalizados en el servicio de Neurocirugía y Otorrinolaringología del Consorcio Hospital General de Valencia durante el primer trimestre del año 2007, mediante mediciones secuenciales y efectuadas por el mismo observador con ambos aparatos bien calibrados. Se observó mediante el método de correlación bivariada de Pearson que no existen diferencias estadísticamente significativas entre las presiones tomadas por ambos aparatos det…
Blood pressure control in treated hypertensive patients in daily practice of Latvian family physicians.
2011
Background and Objective. The aim of this study was to evaluate blood pressure (BP) control level in treated hypertensive patients in Latvia and to compare their characteristics according to the adequacy of BP control. Materials and Methods. Family physicians collected information on demographic and clinical characteristics, and current antihypertensive treatment of 455 18–80-year-old patients with essential arterial hypertension treated for 1 or more years. Target BP was defined as values of <140/90 mm Hg for patients with low or moderate cardiovascular risk and <135/85–125/75 mm Hg for patients with high or very high risk. BP was measured in the office setting after a 5-minute rest …