Search results for "Spinal fusion"
showing 10 items of 50 documents
Overview of Minimally Invasive Spine Surgery
2020
Minimally invasive spine surgery (MISS) has continued to evolve over the past few decades, with significant advancements in technology and technical skills. From endonasal cervical approaches to extreme lateral lumbar interbody fusions, MISS has showcased its usefulness across all practice areas of the spine, with unique points of access to avoid pertinent neurovascular structures. Adult spine deformity has also recognized the importance of minimally invasive techniques in its ability to limit complications and to provide adequate sagittal alignment correction and improvements in patients' functional status. Although MISS has continued to make significant progress clinically, consideration …
Minimal invasive posterior correction of Lenke 5C idiopathic scoliosis: comparative analysis of minimal invasive vs. open surgery
2019
Introduction Surgical management of adolescent idiopathic scoliosis in spite of usually favourable outcomes is still a major operation. Therefore, efforts are being undertaken to minimalize the procedure, reduce the surgical trauma and postoperative convalescence. The study was designed to compare posterior minimal invasive surgery using navigation based on intraoperative 3D imaging and standard open instrumented fusion in Lenke 5C idiopathic scoliosis treatment. Materials and methods From eight patients with Lenke 5C curves planned for posterior correction and instrumented fusion, four were treated with minimally invasive and four had open procedure. Operation length, estimated blood loss,…
Effectiveness of a 12-month home-based exercise program on trunk muscle strength and spine function after lumbar spine fusion surgery:a randomized co…
2022
Purpose: The effectiveness of a 12-month home-exercise program on trunk muscle strength after lumbar spine fusion surgery was evaluated. Materials and methods: Three months postoperatively, 98 patients were randomized either to the exercise group (EG), with a progressive 12-month home-based exercise program, or to usual care group (UCG), with one guidance session for light home-exercises. Maximal trunk muscle strength was measured by a strain-gauge dynamometer and trunk extensor endurance was measured by Biering-Sørensen’s test at baseline and after the intervention. Results: The mean change in extension strength during the intervention was 75 N in EG and 58 N in UCG. Flexion strength impro…
The early changes in trunk muscle strength and disability following lumbar spine fusion
2012
To analyze trunk muscle function pre- and postoperatively in patients undergoing lumbar spine fusion. Associations between changes in trunk muscle strength and disability were also studied.A total of 114 patients undergoing lumbar spine fusion participated in the study. The flexion and extension strength of the trunk was measured preoperatively and 3 months after surgery using a strain-gauge dynamometer. Disability and pain during the past week was evaluated with the Oswestry disability index (ODI) and visual analog scale (VAS), respectively.Preoperative trunk extension and flexion strength levels were 319 N and 436 N in males, respectively, and 160 N and 214 N in females, respectively. In …
Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion T…
2017
Background Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint. Study Aims We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation. Methods A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups acc…
Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion.
2019
Abstract Background Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five cond…
High frequency of lumbar fusion in patients denied surgical treatment of the sacroiliac joint.
2019
Purpose: Effective treatment of medical conditions relies on proper diagnosis. Clinical trials show the safety and effectiveness of sacroiliac joint (SIJ) fusion in patients with chronic SI joint dysfunction. To what extent is the condition under recognised? Objective: To determine whether under recognition of SIJ pain affects healthcare trajectories in Spanish patients with low back pain. Methods: Retrospective study of characteristics and consequences of 189 patients with persistent SIJ pain seen in an outpatient neurosurgery clinic. Results: Patients with SIJ pain who were denied surgical treatment had a longer pain duration, higher likelihood of prior lumbar fusion, and a high rate (63%…
Preliminary Experience with a Novel System of Facet Fixation to Treat Patients with Lumbar Degenerative Disease. A New Perspective in Minimally Invas…
2017
Purpose We report our experience with a novel surgical device for the treatment of lumbar degenerative microinstability. Facet Wedge (DePuy Synthes, Raynham, Massachusetts, United States) is a novel technique of intra-articular lumbar facet fixation that provides a minimally invasive alternative to standard posterior fixation. Materials and Methods From November 2014 to July 2015, 38 patients underwent single-level Facet Wedge implantation. The main surgical indications included herniated disk (18 patients), spinal canal and foraminal stenosis (14 patients), and Meyerding grade I degenerative spondylolisthesis (6 patients). All the patients showed radiologic signs of microinstability: hype…
Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten
1997
PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…
Bestimmung der Knochenqualität vor Wirbelsäuleninstrumentation - Stellenwert verschiedener in vivo-Methoden
2008
OBJECTIVE: The present investigation should elucidate which assessment technique for bone quality is most appropriate to estimate preoperatively fixation strength of instrumental spine fusions. METHODS: VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pullout force assessment. Bone quality was assessed by Dual Energy X-ray Absorptiometry (DEXA), Quantitative Computed Tomography (QCT), MRT and histomorphometry. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS: Highest correlation was found for cancellous bone density (QCT) (r = 0.72; p < 0.001) and DEXA (r = 0.70; p < 0.001). MRT, cortical bo…