Search results for "Spirometer"
showing 9 items of 9 documents
Replacement of fishmeal with corn gluten meal in feeds for juvenile rainbow trout (Oncorhynchus mykiss) does not affect oxygen consumption during for…
2017
Abstract We compared oxygen consumption (MO 2 , mg/kg/h) of c. 80 g rainbow trout ( Oncorhynchus mykiss ) in an intermittent-flow swim respirometer at 15 °C. Before the tests the fish were grown in flow through tanks (15 °C) with either fishmeal (FM) or corn gluten meal (CGM) based diets (c. 52% protein) for a period of 3–4.5 months. Ten individuals from both treatment groups were fasted for 48 h before the swim test, which consisted of 18 loops of 210 s over three different periods: acclimation period (6 loops at 0.5 body lengths per s, BL/s), exercise period (8 loops at increased speed from 1 to 2.5 BL/s with recovery loops at 0.5 BL/s), and a recovery period (four loops at 0.5 BL/s). We …
Expiratory airflow obstruction due to tracheostomy tube: A spirometric study in 50 patients
2018
OBJECTIVES Tracheostomy is commonly used in intensive care units and in head and neck departments. Airway obstruction due to occluded cuffless tracheostomy tubes themselves remains unknown, although capping trials are commonly used before decannulation. The aim of this study was to evaluate the extent to which airway obstruction can be caused by occluded cuffless tubes in patients who underwent head and neck surgery. DESIGN Prospective Research Outcome. SETTINGS University teaching hospital. PARTICIPANTS Fifty patients requiring transient tracheostomy after head and neck surgery. MAIN OUTCOME MEASURES A flow-volume loop (FVL) through the mouth using a portable spirometer, with the occluded …
Cadmium, mercury, and lead effects on gill tissue of freshwater crayfishProcambarus clarkii (girard)
1989
Intermolt adult crayfish P. clarkii were used for this work. After acclimatization to laboratory conditions crayfish were exposed to sublethal concentrations of cadmium, mercury, and lead for 96 h. Gills of control and exposed crayfish were removed and ATPase activity and oxygen uptake rate were determined. Structural damage of gill filaments was also observed. Gill tissue respiration rates were measured for individual crayfish using a Gilson differential respirometer. Lead causes a decrease of gill oxygen uptake, but neither cadmium nor mercury seems to affect it at the concentrations employed. Although all metals studied alter gill filament structure, lead damage is the most apparent. In …
Ventilation volumes with different self-inflating bags with reference to the ERC guidelines for airway management: comparison of two compression tech…
2000
The 1998 ERC-guidelines for airway-management recommend an tidal volume of 400-600 ml for adults undergoing CPR. As commercially available self-inflating bags were designed to meet former recommendations (800-1200 ml) we investigated how to meet the latest recommendations with these bags. We combined the head of a training manikin (Laerdal Medical) and a standard lung (VTTL; Michigan Instrument), adjusted to a physiological compliance and resistance. Volume was measured with a Wright spirometer (BOC). Seven self-inflating bags were investigated. Tests were carried out by ten people (five female and five male) for 5 min each using two different techniques. Technique 1: standard ventilation w…
Quality Control of Spirometry in the Elderly
2000
We evaluated the outcome of the spirometry quality control program of the SA.R.A. multicenter project, the aim of which is the multidimensional assessment of asthma and COPD in the elderly ( ⩾ 65 yr). The factors determining this quality were also evaluated. The program was based on standardized procedures (ATS recommendations), performed by specifically trained and certified personnel; a fully-computerized spirometer with customized software was used for spirometry. A reference center made monthly controls. Overall, 638 cases and 984 controls were examined. Spirometric measurements were obtained in 607 cases and 912 controls; 508 and 747 tests with at least three acceptable curves were obt…
Lung Function Monitoring; A Randomized Agreement Study
2016
Objective: To determine the agreement between devices and repeatability within devices of the forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF) and forced expiratory flow at 50% of FVC (FEF50) values measured using the four spirometers included in the study. Methods: 50 (24 women) participants (20-64 years of age) completed maximum forced expiratory flow manoeuvres and measurements were performed using the following devices: MasterScreen, SensorMedics, Oxycon Pro and SpiroUSB. The order of the instruments tested was randomized and blinded for both the participants and the technicians. Re-testing was conducted on a following day within 72 hours …
A device to trigger automatically electrical stimulation at different states of in- or expiration on the background of variable lung inflation in the…
1975
A device is described which permits to obtain a signal at the beginning of in- or expiration respectively. This signal may be used to trigger an electrical stimulator. To permit studies at different states of lung inflation the tracheal cannula is connected to a spirometer circuit. To produce constant positive or negative air pressure this bellows-type spirometer is loaded with exchangeable metal weights. The tracheal pressure is recorded by means of a pressure transducer, the output of which is taken as signal. The device allows accurate compensation of the DC-component of the transducer output resulting from spirometer operation at a maintained positive or negative pressure.
Development and validation of a bioenergetics model for juvenile and adult burbot
2003
Oxygen consumption of juvenile and adult burbot Lota Iota was measured in an intermittent-flow respirometer to determine the effect of temperature and fish body mass on metabolic rate. These results were combined with data from earlier experiments and the 'Wisconsin bioenergetics' model was constructed. The model was validated under laboratory conditions by comparing observed and predicted food consumption and growth of burbot fed on dead vendace Coregonus albula. There was a good correspondence between observed and estimated growth and food consumption under experimental conditions: the mean absolute per cent errors of growth and food consumption were 4.8 and 24.0%. Estimated values with t…
Replacement of fishmeal with corn gluten meal in feeds for juvenile rainbow trout (Oncorhynchus mykiss) does not affect oxygen consumption during for…
2017
We compared oxygen consumption (MO2, mg/kg/h) of c. 80 g rainbow trout (Oncorhynchus mykiss) in an intermittent-flow swim respirometer at 15 °C. Before the tests the fish were grown in flow through tanks (15 °C) with either fishmeal (FM) or corn gluten meal (CGM) based diets (c. 52% protein) for a period of 3–4.5 months. Ten individuals from both treatment groups were fasted for 48 h before the swim test, which consisted of 18 loops of 210 s over three different periods: acclimation period (6 loops at 0.5 body lengths per s, BL/s), exercise period (8 loops at increased speed from 1 to 2.5 BL/s with recovery loops at 0.5 BL/s), and a recovery period (four loops at 0.5 BL/s). We did not obser…