Search results for "Standard addition"

showing 10 items of 72 documents

Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction pri…

2007

Abstract Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has bee…

Detection limitChromatographyCentral composite designOrganic ChemistryAnalytical chemistryTemperatureIonic LiquidsGeneral MedicineBiochemistryHigh-performance liquid chromatographyChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryIonic strengthLiquid–liquid extractionStandard additionIonic liquidHumansSample preparationChromatography LiquidJournal of chromatography. A
researchProduct

A rapid and sensitive gas chromatography-mass spectrometry method for the quality control of perfumes: simultaneous determination of phthalates

2013

A rapid and sensitive analytical gas chromatography-mass spectrometry (GC-MS) method for perfume analysis to determine the phthalates banned by the European Union Regulation on cosmetic samples is presented. This method has been tested in commercial alcoholic perfume samples for the determination of the following seven phthalates: dibutyl phthalate, bis(2-ethylhexyl) phthalate, bis(2-methoxyethyl) phthalate, n-pentyl-isopentylphthalate, di-n-pentyl phthalate, diisopentylphthalate and benzyl butyl phthalate. Sample evaporation and redissolution in ethanol is carried out before GC-MS analysis, with no dilution of the sample. External calibration and standard addition calibration are compared …

Detection limitChromatographyDibutyl phthalateGeneral Chemical EngineeringGeneral EngineeringPhthalateRepeatabilityAnalytical Chemistrychemistry.chemical_compoundchemistryBenzyl butyl phthalateStandard additionmedia_common.cataloged_instanceEuropean unionGas chromatography–mass spectrometrymedia_commonAnal. Methods
researchProduct

Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography

1997

Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–50…

Detection limitChromatographyIon chromatographyIsotope dilutionBromateBiochemistrychemistry.chemical_compoundchemistryBromideStandard additionmedia_common.cataloged_instanceEuropean unionInductively coupled plasma mass spectrometrymedia_commonFresenius' Journal of Analytical Chemistry
researchProduct

Determination of hydroxylated benzophenone UV filters in sea water samples by dispersive liquid-liquid microextraction followed by gas chromatography…

2010

A new analytical method for the determination of four hydroxylated benzophenone UV filters (i.e. 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxybenzophenone (THB)) in sea water samples is presented. The method is based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) determination. The variables involved in the DLLME process were studied. Under optimized conditions, 1000 microL of acetone (disperser solvent) containing 60 microL of chloroform (extraction solvent) were injected into 5 mL of aqueous sample adjusted to pH 4 and containing 10% NaCl…

Detection limitChromatographySilylationOrganic ChemistryGeneral MedicineBSTFAChemical FractionationBiochemistryGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryStandard additionSample preparationSeawaterGas chromatographyGas chromatography–mass spectrometryDerivatizationWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Extractive-spectrophotometric determination of amphetamine in urine samples with sodium 1,2-naphthoquinone 4-sulphonate

1993

Abstract Sodium 1,2-naphthoquinone 4-sulphonate (NQS) was tested as a reagent for amphetamine in order to develop an extractive-spectrophotometric method for the drug in urine samples. The standard additions method showed the absence of proportional bias error whereas the Youden method and the two standard addition plots method showed the presence of a constant bias error [total Youden blank (TYB)]. Acceptable results were obtained by evaluating the TYB error or by using a placebo (urine sample from a normal subject). The dynamic range of concentrations was 1.4–50 mg 1−1 in urine samples and the detection limit was 0.6 mg 1−1 when 10 ml of urine sample were taken.

Detection limitChromatographymedicine.diagnostic_testSodiumExtraction (chemistry)NQSchemistry.chemical_elementUrineBiochemistryAnalytical ChemistrychemistryStandard additionReagentSpectrophotometrymedicineEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Determination of titanium by adsorption voltammetry with 4-(2-pyridylazo) resorcinol

1990

Titanium (IV) forms a complex with 4-(2-pyridylazo) resorcinol (PAR) in weakly acidic solutions. This complex can be used to determine titanium by adsorption voltammetry at a stationary Hg-electrode. The experimental conditions for the determination are described. The current-concentration curve is linear from 0.15–4.8 ng/g. Ti at a deposition time of 3 min, the detection limit lies at 0.1 ng/g. The influence of foreign ions was investigated. The determination can be carried out in the presence of a 1000-fold excess of iron by the standard addition method, albeit with decreased sensitivity.

Detection limitInorganic chemistrychemistry.chemical_elementResorcinolBiochemistryAnalytical ChemistryIonchemistry.chemical_compoundAdsorptionchemistryStandard additionElectrodeVoltammetryTitaniumFresenius' Journal of Analytical Chemistry
researchProduct

Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser …

2003

Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between t…

Detection limitLaser ablationChemistryStandard additionAnalytical chemistryAnalytical proceduresSample preparationIsotope dilutionMicrowave digestionBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryAnalytical and bioanalytical chemistry
researchProduct

Calibration of LA-ICP-MS via standard addition using dried picoliter droplets

2020

A novel microanalytical calibration approach for quantitative spatially resolved analysis of thin layered materials with laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is presented. This method relies on standard addition via the generation of dried pL-droplet residues. Therefore, a drop on demand dosing device based on a modified commercial ink cartridge and a dosing interface, both accessible via a self-constructed microcontroller, were developed. This dosing device enables the precise deposition of pL-droplets onto solid samples for the generation of residues with dimensions in the low μm-range. The LA-ICP-MS analysis of such residues allows calibration over at l…

Detection limitMaterials scienceThin sectionSample (material)010401 analytical chemistryAnalytical chemistry02 engineering and technologyRepeatability021001 nanoscience & nanotechnologyMass spectrometryLaser01 natural sciences0104 chemical sciencesAnalytical Chemistrylaw.inventionCartridgelawStandard addition0210 nano-technologySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

ATR-FTIR and XRD quantification of solid mixtures using the asymptotic constant ratio (ACR) methods. Application to geological samples of sodium and …

2019

Two asymptotic constant ratio methods applied to the quantification of individual components of solid samples using attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray diffraction (XRD) are described. The methods involve the measurement of the peak current/peak areas of selected signals (diffraction peaks in XRD and absorption bands in ATR-FTIR) relative to the signal of standard added in constant proportion to the sample and the sample enriched with the analyte following the usual standard additions methodology. The proposed method compensates the absorption effects appearing in XRD and the presence of overlapping absorption bands of interferents by me…

DiffractionChemistryPotassiumSodiumAnalytical chemistryInfrared spectroscopychemistry.chemical_element02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and Optics0104 chemical sciencesAnalytical ChemistryMatrix (chemical analysis)Standard additionFourier transform infrared spectroscopy0210 nano-technologyAbsorption (electromagnetic radiation)InstrumentationSpectroscopySpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
researchProduct

A method for measuring low-weight carboxylic acids from biosolid compost

2006

Concentration of low-weight carboxylic acids (LWCA) is one of the important parameters that should be taken into consideration when compost is applied as soil improver for plant cultivation, because high amounts of LWCA can be toxic to plants. The present work describes a method for analysis of LWCA in compost as a useful tool for monitoring compost quality and safety. The method was tested on compost samples of two different ages: 3 (immature) and 6 (mature) months old. Acids from compost samples were extracted at high pH, filtered, and freeze-dried. The dried sodium salts were derivatized with a sulfuric acid–methanol mixture and concentrations of 11 low-weight fatty acids (C1–C10) were a…

Environmental EngineeringChromatography GasCarboxylic acidAlkalinityCarboxylic AcidsLWCAManagement Monitoring Policy and Lawengineering.materialcomplex mixturesLepidiumSoilWaste Management and DisposalWater Science and Technologychemistry.chemical_classificationDetection limitChromatographyChemistryCompostfungiPollutionlow-weight carboxylic acidsCapric AcidStandard additionCalibrationengineeringGas chromatographySludgeJournal of Environmental Quality
researchProduct