Search results for "Stents"
showing 10 items of 229 documents
Optimizing endovascular stroke treatment: removing the microcatheter before clot retrieval with stent-retrievers increases aspiration flow
2016
BackgroundFlow control during endovascular stroke treatment with stent-retrievers is crucial for successful revascularization. The standard technique recommended by stent-retriever manufacturers implies obstruction of the respective access catheter by the microcatheter, through which the stent-retriever is delivered. This, in turn, results in reduced aspiration during thrombectomy. In order to maximize aspiration, we fully retract the microcatheter out of the access catheter before thrombectomy—an approach we term the ‘bare wire thrombectomy’ (BWT) technique. We verified the improved throughput with systematic in vitro studies and assessed the clinical effectiveness and safety of this metho…
The intravascular ultrasound morphometry of iliac veins in subjects without severe chronic venous insufficiency and its implications for treatment in…
2019
Objectives The purpose of this study is to report the intravascular ultrasound morphometry of iliac veins and its relation to demographic and anthropometric factors in subjects without chronic venous insufficiency. Methods Thirty-three patients, without chronic venous insufficiency – qualified to great saphenous vein stripping due to unilateral, primary varicose veins – participated in the study. During the surgery, left and right external iliac veins, common iliac veins and inferior vena cava were interrogated with intravascular ultrasound. The morphometric analysis included measurement of a cross-sectional area at normal, non-stenosed vein segments (ref-CSA) and at the point of the most p…
Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review.
2017
Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 Ã 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endo…
Endovascular management of carotid artery dissections with the use of new generation stents and protection systems
2016
Dissection of the internal carotid artery (ICA) is a rare disease, but in young patients is responsible for about 20% of cerebral events. We presented three different cases of ICA dissection, including one iatrogenic and two spontaneous ones, which were successfully managed endovascularly, with the use of different techniques, different protection devices and stents. In this article, the clinical management and details of procedures were described.
One-year results from the DETOUR I trial of the PQ Bypass DETOUR System for percutaneous femoropopliteal bypass
2019
The objective of this study was to evaluate the 1-year safety and effectiveness outcomes associated with the PQ Bypass DETOUR System (PQ Bypass, Milpitas, Calif) for the percutaneous bypass of long-segment femoropopliteal occlusive disease.This prospective, single-arm, multicenter trial enrolled patients with long-segment femoropopliteal arterial disease. The DETOUR System percutaneously deploys modular stent grafts to bypass femoropopliteal lesions through a transvenous route. Eligible patients included those with TransAtlantic Inter-Society Consensus C and D lesions100 mm in length. The primary safety end point was the major adverse event (MAE) rate through 1 month, defined as the composi…
Multidisciplinary approach to the complex treatment for non-cirrhotic portal hypertension - case-report-based discussion.
2021
Non-cirrhotic portal vein thrombosis (PVT) in patients with antiphospholipid syndrome (APS) is a rare complication, and the management has to be determined individually based on the extent and severity of the presentation. We report on a 37-year-old male patient with non-cirrhotic chronic PVT related to a severe thrombophilia, comprising APS, antithrombin-, factor V- and factor X-deficiency. Three years after the initial diagnosis of non-cirrhotic PVT, the patient presented with severe hemorrhagic shock related to acute bleeding from esophageal varices, requiring an emergency transjugular intrahepatic portosystemic stent shunt (TIPSS). TIPSS was revised after a recurrent bleeding episode du…
Stentgraft-Implantation for Treatment of Internal Carotid Artery Injury during Endonasal Sinus Surgery
2007
Background Damage of the internal carotid artery (ICA) is very rare but can be a dramatic complication of endonasal sinus surgery. In the literature only a few cases are reported, some of them with fatal results. Methods We present two cases with massive bleeding of the ICA caused by endonasal sinus surgery. Results In both cases bleeding could be stopped sufficiently by implanting a stentgraft. Conclusion The lumen of the artery could be preserved and no neurological deficits were observed.
Midterm Results of the Treatment of Penetrating Abdominal Aortic or Iliac Artery Ulcer with the BeGraft Balloon-Expandable Covered Stent-A Single-Cen…
2020
Background The purpose of the study was to evaluate the feasibility and efficacy of the novel BeGraft covered stent for the treatment of abdominal penetrating aortic ulcer (PAU) or penetrating ulcers of the iliac arteries (PUIAs). Methods This was a single-center observational study, which included 24 consecutive patients who underwent endovascular surgery due to abdominal PAU or PUIA between June 2017 and September 2019. Demographics of patients, lesion characteristics, diameter and length of the BeGraft stents, and postoperative events were prospectively collected and retrospectively analyzed. Follow-up examinations were performed at 1, 6, 12, and 24 months with clinical and hemodynamic e…
Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms
2011
Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…
Short and long term results after intracoronary stenting in human coronary arteries: monocentre experience with the balloon-expandable Palmaz-Schatz …
1991
OBJECTIVE--Intracoronary stenting was designed to overcome acute complications after percutaneous transluminal coronary angioplasty and to achieve a reduced rate of restenosis, both of which are major limitations of this well accepted method for treating coronary heart disease. This report describes the experience at one centre with the implantation of balloon-expandable Palmaz-Schatz stents and focuses on device related complications and the short and long term angiographic outcome. DESIGN--A retrospective data analysis. PATIENTS--Stenting was attempted in 50 patients. Restenosis after an initially successful angioplasty procedure, inadequate postangioplasty results, saphenous coronary byp…