Search results for "Stiffness"
showing 10 items of 524 documents
A multicriterion design of steel frames with shakedown constraints
2006
The minimum volume design of elastic perfectly plastic steel frames subjected to fixed and cyclic loads is searched in such a way that the structure remains in elastic field in serviceability conditions, while it is subjected to alternating plasticity under very strong cyclic actions, incremental and instantaneous collapse being prevented. The problem is faced on the grounds of a statical and a kinematical approach. The Kuhn-Tucker conditions of the two problems prove that they are each one the dual of the other and provide useful pieces of information about the structural behaviour. Numerical applications confirm the theoretical expectations: optimal designs turn out to be quite light, wit…
On the Post-Elastic Behavior of LRPH Connections
2019
The paper concerns the study of the post-elastic behavior of a recently proposed innovative device, named Limited Resistance Rigid Perfectly Plastic Hinge (LRPH). In particular, LRPH is a steel device of finite length realizing a moment connection between beam elements of a steel frame; it is designed in order to possess two main and independent requirements: its bending moment resistance must be suitably lower than the one of the connected beam element and its overall bending stiffness must be equal to that of the connected beam element characterized by the same length. In order to make the proposed device reliable, LRPH must be capable of realizing a full plastic hinge for the assigned be…
Influence of formalin fixation on the biomechanical properties of human diaphyseal bone.
2010
Owing to the lack of fresh human bones, formalin-fixed specimens are frequently used in biomechanical testing. However, formalin fixation is assumed to affect the biomechanical properties of bone. The aim of this study was to compare axial and torsional stiffness and bone mineral density in fresh and embalmed human bones. The subtrochanteric regions of 12 pairs of fresh human femora were randomised into two groups for paired comparison. After bone mineral density measurement, one group was preserved in 4% formalin. After 6 weeks, bone mineral density was remeasured and each specimen underwent axial and torsional loading. The formalin group showed significant higher stiffness values for tors…
Sind winkelstabile Plattensysteme mit elastischen Eigenschaften für die Stabilisierung der Oberarmkopffraktur vorteilhaft? / Eine in-vitro biomechani…
2004
AbstractWinkelstabile Platten werden mit zunehmender Häufigkeit zur Stabilisierung von Oberarmkopfbrüchen verwendet. Rigide Implantate führen bei osteoporotischen Knochenverhältnissen u. U. aber häufiger zum Versagen. Um den Effekt der Implantatelastizität zu beurteilen wurden in einer in-vitro Studie die biomechanischen Eigenschaften eines rigiden und eines elastischen winkelstabilen Plattensystems vergleichend analysiert. An 8 Humeruspaaren wurde eine instabile subkapitale Fraktur simuliert. Die Proben wurden axial- und torsions-belastet. Analysiert wurden die Steifigkeit, das Setzverhalten unter Dauerlast und die Versagensbelastung.Das elastische Plattensystem kennzeichnete sich durch ei…
Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study
2011
Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…
Repeatability of a computer-controlled posterior to anterior vertebral stiffness in subjects with thoracic spine pain
2015
Fatigue of Mooring Chains Connected to Offshore Floating Structures Considering Out of Plane Bending Effects
2019
Abstract Reliability against fatigue fracture is an issue of major concern in the design of offshore mooring systems with chain segments. The present paper describes the investigation of the effect of OPB (out of plane bending) and IPB (in plane bending) loading modes on the fatigue performance of chain links in critical positions. The hang-off design at the floater is based on long rods with bearings at the connection points to the floating structure. The purpose of the paper is to shed some light on possible design improvements on the connection design when using the available design guidelines for calculation of combined Tension-Bending fatigue in the mooring line. A challenge when using…
Out-of-plane behaviour of unreinforced masonry infill walls: Review of the experimental studies and analysis of the influencing parameters
2021
Abstract Over the last 50 years, research has mainly focused on characterizing the In-Plane behaviour of unreinforced masonry infill walls. Recently, the focus of research has been addressed to understanding Out-of-Plane behaviour, also from the experimental point of view. However, in the experimental campaigns, there is high variability in the geometrical and mechanical properties of URM infill walls and also in the application of Out-of-Plane loads. Therefore, it is important to outline and critically evaluate the major findings obtained by experimental studies and identify research gaps to better understand the differences and the affinity of apparently equivalent tests. In this paper, t…
Liver stiffness measurement by transient elastography predicts early recovery from acute hepatitis
2010
We read with interest the lead article by Castera and Pinzani,1 particularly the comment regarding the role of transient elastography (TE) in the context of acute hepatitis (AH). The assumption that liver stiffness is determined exclusively by hepatic fibrosis has been challenged by evidence that patients with AH can have high values of liver stiffness measurement (LSM) by TE.2 AH is a suitable model for studying the kinetics of LSM, since inflammation and necrosis increase rapidly and sometimes massively, but may revert with equal speed. We evaluated 92 consecutive patients (mean age 41.8±16.3 years, 71.7% males) with symptomatic AH to assess how LSM was influenced by aetiology, and whethe…
Immune-inflammatory markers and arterial stiffness indexes in subjects with acute ischemic stroke with and without metabolic syndrome.
2014
Objective: The aim of our study was to evaluate the associations between arterial stiffness indexes and immune-inflammatory markers in subjects with acute ischemic stroke with and without metabolic syndrome. Materials/Methods: We enrolled 130 patients with acute ischemic stroke and metabolic syndrome, 127 patients with acute ischemic stroke without metabolic syndrome and 120 control subjects without acute stroke. Applanation tonometry was used to record the augmentation index (Aix) and pulse wave velocity (PWV). We also evaluated plasma levels of C-reactive protein (CRP), Interleukin-1beta (IL-1β), tumor necrosis factor-alpha (TNF-α), Interleukin-6 (IL-6) and Interleukin-10 (IL-10), E-selec…