Search results for "Stiffness"
showing 10 items of 524 documents
Evaluating pulp stiffness from fibre bundles by ultrasound
2012
A non-destructive ultrasonic tester was developed to measure the stiffness of pulp bundles. The mechanical properties of pulp are important when estimating the behaviour of paper under stress. Currently available pulp tests are tedious and alter the fibres structurally and mechanically. The developed tester employs (933 ± 15) kHz tweezer-like ultrasonic transducers and time-of-flight measurement through (9.0 ± 2.5) mm long and (0.8 ± 0.1) mm thick fibre bundles kept at (19.1 ± 0.4) °C and (62 ± 1)% RH. We determined the stiffness of soft wood pulps produced by three kraft pulping modifications: standard kraft pulp, (5.2 ± 0.4) GPa, prehydrolysis kraft pulp, (4.3 ± 0.4) GPa, and alkali extra…
Mechanical and neural stretch responses of the human soleus muscle at different walking speeds
2009
During human walking, a sudden trip may elicit a Ia afferent fibre mediated short latency stretch reflex. The aim of this study was to investigate soleus (SOL) muscle mechanical behaviour in response to dorsiflexion perturbations, and to relate this behaviour to short latency stretch reflex responses. Twelve healthy subjects walked on a treadmill with the left leg attached to an actuator capable of rapidly dorsiflexing the ankle joint. Ultrasound was used to measure fascicle lengths in SOL during walking, and surface electromyography (EMG) was used to record muscle activation. Dorsiflexion perturbations of 6 deg were applied during mid-stance at walking speeds of 3, 4 and 5 km h(-1). At eac…
Ultimate strain and deformability of elementary flax fibres
2011
Flax fibres possess high specific strength and stiffness, and thus are competitive in terms of mechanical properties with the traditional reinforcing fibres used in polymer-matrix composite materials. The mechanical properties of fibres have considerable variability that needs to be characterized and allowed for in the analysis of mechanical response of composites. In this study, the distribution of ultimate strain of elementary flax fibres and its dependence on gauge length is considered. The applicability of the modified Weibull distribution, used for fibre strength, to fibre ultimate strain is evaluated. A simplified relation of ultimate strain and fibre strength distributions is propos…
Magnus and Fer expansions for matrix differential equations: the convergence problem
1998
Approximate solutions of matrix linear differential equations by matrix exponentials are considered. In particular, the convergence issue of Magnus and Fer expansions is treated. Upper bounds for the convergence radius in terms of the norm of the defining matrix of the system are obtained. The very few previously published bounds are improved. Bounds to the error of approximate solutions are also reported. All results are based just on algebraic manipulations of the recursive relation of the expansion generators.
The Role of Nutraceuticals in Statin Intolerant Patients.
2018
Abstract Statins are the most common drugs administered for patients with cardiovascular disease. However, due to statin-associated muscle symptoms, adherence to statin therapy is challenging in clinical practice. Certain nutraceuticals, such as red yeast rice, bergamot, berberine, artichoke, soluble fiber, and plant sterols and stanols alone or in combination with each other, as well as with ezetimibe, might be considered as an alternative or add-on therapy to statins, although there is still insufficient evidence available with respect to long-term safety and effectiveness on cardiovascular disease prevention and treatment. These nutraceuticals could exert significant lipid-lowering activ…
Potassium Triggers a Reversible Specific Stiffness Transition of Polyethylene Glycol
2017
We use plasmon rulers made from two connected gold nanoparticles to monitor the conformation and stiffness of single PEG molecules and their response to cations. By observing equilibrium fluctuations of the interparticle distance, we obtain the spring constants or stiffness of the connecting single-molecule tether with pico-Newton sensitivity. We observe a transition of the PEG molecules’ extension and stiffness above about 1.2 mM K+ ion concentration which is specific to potassium ions. Molecular dynamics simulations reveal the formation of crown-like structures as the most likely molecular mechanism responsible for this specific effect.
L’associazione tra stiffness aortica e proteina C-reattiva è indipendente dalla microalbuminuria nell’ipertensione essenziale
2008
Prediction of Airport Pavement Moduli by Machine Learning Methodology Using Non-destructive Field Testing Data Augmentation
2022
For the purpose of the Airport Pavement Management System (APMS), in order to optimize the maintenance strategies, it is fundamental monitoring the pavement conditions’ deterioration with time. In this way, the most damaged areas can be detected and intervention can be prioritized. The conventional approach consists in performing non-destructive tests by means of a Heavy Weight Deflectometer (HWD). This equipment allows the measurement of the pavement deflections induced by a defined impact load. This is a quite expensive and time-consuming procedure, therefore, the points to be investigated are usually limited to the center points of a very large mesh grid. Starting from the measured defle…
On the improvement of monumental structure safety: a case study
2006
The present paper deals with the problem of the preservation of the monumental patrimony and discusses a practical application. The analysis methodology based on modern dynamic identification techniques was used for a monumental church in the historic area of Catania (Italy). The dynamic response of the church was measured in terms of accelerations, by means of vibration tests in situ. The numerical analyses highlighted the vulnerability of the drum dome system. Hence interest focused on this part of the building. A reduced scale model of the above system was built to be subjected to dynamic tests on a shaking table at the ENEA laboratory at Casaccia (Rome). Different kinds of reversible de…
Biomechanical comparison between the modified rolling-hitch and the modified finger-trap suture techniques
2016
Purpose: The purpose of this study was to characterize the biomechanical effect of two grasping suture techniques used during ligament reconstruction: the modified rolling-hitch (MRH) and the modified finger-trap (MFT). Methods: Flexor profundus tendons were harvested from fresh pig hind-leg trotters. Each specimen was mounted on an electro-mechanic universal testing machine (Instron 3367). In half of all tendons (15 specimens), the suture was passed around the tendon following the MRH knot (Group 1). In the remaining half of all tendons (15 specimens), the suture was passed over a distance of 30 mm according to the MFT suture technique (Group 2). As per standard intra-operative technique, …