Search results for "Surgical Instruments"
showing 10 items of 23 documents
Intussuscepted ileal flap valve for revisional surgery.
2005
The Clip Approach : A Visual Methodology to Support the (Re)Construction of Life Narratives
2021
Major life changes may cause an autobiographical rupture and a need to work on one’s narrative identity. This article introduces a new qualitative interview methodology originally developed to facilitate 10 prostate cancer patients and five spouses in the (re)creation of their life narratives in the context of a series of interventive interviews conducted over a timespan of several months. In “The Clip Approach” the interviewees’ words, phrases, and metaphors are reflected back in a physical form (“the Clips”) as visual artifacts that allow the interviewees to re-enter and re-consider their experience and life and re-construct their narratives concerning them. Honoring the interviewees as …
Absolok® versus Hem-o-Lok® clips for renorrhaphy during partial nephrectomy for parenchymal renal tumors
2020
Background To compare perioperative and functional outcomes associated with renorrhaphy performed with two different types of clips (Absolok® vs. Hem-o-Lok®) in a contemporary series of patients who underwent partial nephrectomy. Methods Patients in whom Absolok® clips were used to perform haemostasis at the level of tumor bed or to block the running sutures during sliding-clip renorrhaphy (study group) were compared with a contemporary control group of patients in whom renorrhaphy was performed with Hem-o-Lok® clips. Both groups received the same surgical technique via an open or robot-assisted approach. Inner renorrhaphy was performed with one or more 3-0 (26 mm needle) monofilament runni…
Waterjet Dissection of Peripheral Nerves: An Experimental Study of the Sciatic Nerve of Rats
2010
BACKGROUND: Although waterjet dissection has been well evaluated in intracranial pathologies, little is known of its qualities in peripheral nerve surgery. Theoretically, the precise dissection qualities could support the separation of nerves from adjacent tissues and improve the preservation of nerve integrity in peripheral nerve surgery. OBJECTIVE: To evaluate the potential of the new waterjet dissector in peripheral nerve surgery. METHODS: Waterjet dissection with pressures of 20 to 80 bar was applied on the sciatic nerves of 101 rats. The effect of waterjet dissection on the sciatic nerve was evaluated by clinical tests, neurophysiological examinations, and histopathological studies up …
Time interval between infective endocarditis first symptoms and diagnosis: relationship to infective endocarditis characteristics, microorganisms and…
2016
International audience; OBJECTIVE: To analyze the characteristics and outcome of infective endocarditis (IE) according to the time interval between IE first symptoms and diagnosis.METHODS: Among the IE cases of a French population-based epidemiological survey, patients having early-diagnosed IE (diagnosis of IE within 1 month of first symptoms) were compared with those having late-diagnosed IE (diagnosis of IE more than 1 month after first symptoms).RESULTS: Among the 486 definite-IE, 124 (25%) had late-diagnosed IE whereas others had early-diagnosed IE. Early-diagnosed IE were independently associated with female gender (OR = 1.8; 95% CI [1.0-3.0]), prosthetic valve (OR= 2.6; 95% CI [1.4-5…
Minor hepatic resection for hepatocellular carcinoma in cirrhotic patients: Kelly clamp crushing resection versus heat coagulative necrosis with bipo…
2011
Hemorrhage and postoperative liver insufficiency are frequent and serious complications of hepatic resection in cirrhotic patients. The aim of this study was to assess retrospectively whether the surgical techniques using Kelly clamp crushing resection or heat coagulative necrosis with a bipolar radiofrequency device can reduce the incidence of the above complications and an eventual recurrence of neoplasia on the liver slice. We retrospectively reviewed the results of 35 patients who had undergone resection for monofocal hepatocellular carcinoma at our center. Thirteen patients (Group A) had undergone liver resection with Kelly clamp crushing resection, 22 patients (Group B) had had liver…
Analysis of high-frequency rotational angioplasty-induced echo contrast.
1991
During high-frequency rotational angioplasty (HFRA), myocardial contrast enhancement (echo contrast) was observed by means of two-dimensional echocardiography. In order to evaluate the echo contrast produced by HFRA, an in vitro experimental model was built using a cylinder with the HFRA catheter scanned in a water bath. The cylinder was filled with blood, mineral water, and distilled water. With a 2.5-MHz transducer, echograms were recorded and analyzed by video intensitometer, and the maximum intensity IUmax and persistence time P were calculated. Rotation frequencies of 20,000-200,000 rpm with 2.0--mm burrs and times of 10 s were tested. In another model, hyperbaric conditions for the sa…
The subway tunneling technique for distal shunt catheter insertion.
2019
Dear Editor,We read with interest the article by Osman et al. titled ‘Trocar assisted distal shunt tube insertion with intra-operative X-Ray confirmation’. The authors purpose their technique to pl...
Simplified orthotopic ileocaecal pouch (Mainz pouch) for bladder substitution
2005
New applicator improves waterjet dissection quality
2010
Waterjet dissection is accomplished with Helix Hydro-Jet, but a new device with improved operative handling and potentially superior dissection qualities has been developed.Eighty-four fresh cadaveric pig brains were simultaneously cut with Helix Hydro-Jet and Erbejet 2. A commonly used applicator and a new applicator for the Helix Hydro-Jet were directly compared to the new Erbejet 2. Under standardised conditions, different pressure levels were applied to the brain surface without arachnoids. Technical features, cutting depth, tissue damage and differences of applicators were examined.Microscopic analysis of cutting depth revealed different dissection characteristics of both the devices. …