Search results for "Synchro"
showing 10 items of 886 documents
Time-resolved photoemission electron microscopy
2009
The excellent time structure of Synchrotron radiation and short-pulse lasers has opened the door to a novel way of time-resolved imaging using PEEM. Periodic or repetitive processes can be studied by stroboscopic illumination with the pulsed photon beam. Since the first experiments in 2003, two fields of applications have been established in several groups. One concerns the investigation of fast magnetisation processes like precessional switching, Gigahertz-eigenmodes of ferromagnetic nanostructures or travelling spin waves in thin films. More recently, femtosecond lasers have been used for imaging of localised surface plasmons in nanoparticles and their temporal behaviour in the femtosecon…
Charge Transport Properties in CZT Detectors Grown by the Vertical Bridgman Technique
2010
Great efforts are being presently devoted to the development of CdTe and CdZnTe detectors for a large variety of applications, such as medical, industrial, and space research. We present the spectroscopic properties of some CZT crystals grown by the standard vertical Bridgman method and by the boron oxide encapsulated vertical Bridgman method, which has been recently implemented at IMEM-CNR (Parma, Italy). By this technique the crystal is grown in an open quartz crucible fully encapsulated by a thin layer of liquid boron oxide. This method prevents contact between the crystal and the crucible thereby allowing larger single grains with a lower dislocation density to be obtained. Several mono…
Progress in development of a new luminescence setup at the FinEstBeAMS beamline of the MAX IV laboratory
2019
The main funding for the FinEstBeAMS beamline has been obtained from the European Union through the European Regional Development Fund (project “Estonian beamline to MAX-IV synchrotron”, granted to the University of Tartu) and from the Academy of Finland through the Finnish Research Infrastructure funding projects ( FIRI2010 , FIRI2013 , FIRI2014 ). The authors also acknowledge the funding contributions of the University of Oulu , University of Turku , Tampere University of Technology , the Estonian Research Council ( IUT 2-25 , IUT 2-26 , PRG-111 ), as well as the Estonian Centre of Excellence in Research “Advanced materials and high-technology devices for sustainable energetics, sensorics…
Predictive dead time controller for GaN-based boost converters
2017
A dynamic dead time controller is presented, specifically intended to operate in synchronous boost converters based on GaN field-effect transistor switches. These transistors have a reduced stored charge with respect to silicon metal–oxide–semiconductor field-effect transistors with similar breakdown voltage and series resistance, and can operate at higher frequencies with reduced switching losses. On the other hand, the voltage drop in reverse conduction is typically more than doubled with respect to silicon devices resulting in relevant power losses during the free-wheeling phases. Therefore, dynamic control of dead time can be profitably applied even in converters operating in the tens o…
A heuristic to schedule flexible job-shop in a glass factory
2005
We describe the design and implementation of a scheduling system in a glass factory. The factory produces a large variety of manufactured glass objects in a complex process ranging from melting the glass in the furnaces and blowing it automatically or manually to decorating, assembling and packing it. The structure basically corresponds to a flexible job-shop scheduling problem with some special characteristics. On the one hand, dealing with hot liquid glass imposes no-wait constraints on some operations. On the other hand, skilled workers performing some manual tasks are modelled as special machines. The system produces approximate solutions in very short computing times, trying to minimiz…
Design of a Permanent Magnet Synchronous Generator using Interactive Multiobjective Optimization
2017
We consider an analytical model of a permanent magnet synchronous generator and formulate a mixed-integer constrained multiobjective optimization problem with six objective functions. We demonstrate the usefulness of solving such a problem by applying an interactive multiobjective optimization method called NIMBUS. In the NIMBUS method, a decision is iteratively involved in the optimization process and directs the solution process in order to find her/his most preferred Pareto optimal solution for the problem. We also employ a commonly used noninteractive evolutionary multiobjective optimization method NSGA-II to generate a set of solutions that approximates the Pareto set and demonstrate t…
CERN-MEDICIS: A Review Since Commissioning in 2017
2021
The CERN-MEDICIS (MEDical Isotopes Collected from ISolde) facility has delivered its first radioactive ion beam at CERN (Switzerland) in December 2017 to support the research and development in nuclear medicine using non-conventional radionuclides. Since then, fourteen institutes, including CERN, have joined the collaboration to drive the scientific program of this unique installation and evaluate the needs of the community to improve the research in imaging, diagnostics, radiation therapy and personalized medicine. The facility has been built as an extension of the ISOLDE (Isotope Separator On Line DEvice) facility at CERN. Handling of open radioisotope sources is made possible thanks to i…
Dust Production and Particle Acceleration in Supernova 1987A Revealed with ALMA
2013
Supernova (SN) explosions are crucial engines driving the evolution of galaxies by shock heating gas, increasing the metallicity, creating dust, and accelerating energetic particles. In 2012 we used the Atacama Large Millimeter/Submillimeter Array to observe SN 1987A, one of the best-observed supernovae since the invention of the telescope. We present spatially resolved images at 450um, 870um, 1.4mm, and 2.8mm, an important transition wavelength range. Longer wavelength emission is dominated by synchrotron radiation from shock-accelerated particles, shorter wavelengths by emission from the largest mass of dust measured in a supernova remnant (>0.2Msun). For the first time we show unambig…
Desktop X-ray tomography for low contrast samples
2013
Abstract Based on the experience in the use of polycapillary optical systems, recently XLab Frascati LNF and IM CNR have been strongly involved in studying the techniques for high resolution X-ray Imaging and micro-tomography that intends in the development of a new imaging instrument to examine low contrast samples complicated by fast developing processes. In order to get the reliable signal to noise ratio, typically available via synchrotron radiation (SR) dedicated X-ray optical devices, for the desktop solutions we have to increase the radiation fluxes from conventional sources. As known, manipulated through polycapillary optics beams result in getting higher fluxes with respect to a pi…
A multiscale X-ray phase-contrast tomography dataset of whole human left lung
2021
ABSTRACTTechnological advancements in X-ray imaging using bright and coherent synchrotron sources now allows to decouple sample size and resolution, while maintaining high sensitivity to the microstructure of soft, partially dehydrated tissues. The recently developed imaging technique, hierarchical phase-contrast tomography, is a comprehensive approach to address the challenge of organ-scale (up to tens of centimeters) soft tissue imaging with resolution and sensitivity down to the cellular level. Using this technique, we imaged ex vivo an entire human left lung at an isotropic voxel size of 25.08 μm along with local zooms down to 6.05 - 6.5 μm and 2.45 - 2.5 μm in voxel size. The high tiss…