Search results for "TCATA"

showing 8 items of 8 documents

Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.

2003

We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.

AdultMalemedicine.medical_specialtyCiliary sulcusgenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAphakia PostcataractProsthesis DesignFixation (surgical)Ciliary bodyLens Implantation IntraocularOphthalmologymedicineHumansAgedLenses Intraocularbusiness.industryCiliary BodySuture TechniquesCapsuleeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureIntraocular lensesSurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Effect of head position on refraction in aphakic and phakic silicone-filled eyes.

1997

BACKGROUND The refraction of the eye is altered significantly after the instillation of silicone oil into the vitreous cavity because of the silicone oil's high refractive index. The degree of the refractive change shows diurnal variation and depends on the patient's head position. PATIENTS AND METHODS To analyze the degree and time course of refractive changes with respect to head position, the authors performed objective refraction in five aphakic and five phakic silicone oil-instilled eyes with attached maculae using an automatic hand-held refractometer. In each patient, 25 measurements were taken at short intervals using a hand-held autorefractometer with the patient in different positi…

Malemedicine.medical_specialtySupine positionVisual acuitygenetic structuresPseudophakiaPostureVisual AcuityAphakia PostcataractRefraction Ocularchemistry.chemical_compoundSiliconeRefractometerOphthalmologyMedicineHumansSilicone Oilsskin and connective tissue diseasesDioptreLenses Intraocularbusiness.industryRetinal DetachmentGeneral MedicineMiddle AgedRefractioneye diseasesSilicone oilOphthalmologyRefractometrychemistryHead positionFemalesense organsmedicine.symptombusinessHeadRetina (Philadelphia, Pa.)
researchProduct

Axial Elongation following Cataract Surgery during the First Year of Life in the Infant Aphakia Treatment Study

2012

PURPOSE To compare ocular axial elongation in infants after unilateral cataract surgery corrected with a contact lens (CL) or primary intraocular lens (IOL) implantation. METHODS Baseline axial length (AL) was measured at the time of cataract surgery (1-6 months) and at age 1 year. AL at baseline and age 1 year and the change in length/mo were analyzed in relation to treatment modality, cataractous versus fellow eye, and age at surgery using linear mixed models. RESULTS Mean baseline AL did not differ between the CL and IOL groups for either cataractous or fellow eyes. Eyes with cataracts were shorter than fellow eyes by an average of 0.6 mm (95% confidence interval [CI], 0.4-0.8 mm; P < 0.…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedicine.medical_treatmentVisual AcuityIntraocular lensFirst year of lifeAphakia PostcataractCataract ExtractionAphakiaCataractCataractsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryInfant NewbornInfantArticlesCataract surgerymedicine.diseaseRefractive ErrorsAxial elongationeye diseasesSurgeryContact lensTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up Studies
researchProduct

Photocatalytic oxidation in green organic solvent: the case study of water-insoluble phenanthrene

2014

Phtotcatalytic oxidation phenenthrene green solventSettore CHIM/07 - Fondamenti Chimici Delle Tecnologie
researchProduct

Influence of cheese composition on the aroma content, release and perception

2022

Sensory evaluation[SDV.AEN] Life Sciences [q-bio]/Food and NutritionCheese[SDV.BBM] Life Sciences [q-bio]/Biochemistry Molecular BiologyTCATAAnalytical chemistryPTR-ToF-MS
researchProduct

Characterizing the Dynamic Taste and Retro-Nasal Aroma Properties of Oral Nutritional Supplements Using Temporal Dominance of Sensation and Temporal …

2020

International audience; Orally Disintegrating Tablets (ODTs) are used to restore the nutritional status of people suffering from swallowing pathologies such as dysphagia. ODTs are consumed without water intake and are easily swallowed. The main active compounds of ODTs are vitamins and minerals. These nutrients can have a bad taste or aftertaste, which can be masked by sweetening or flavoring. To ensure the effectiveness of masking strategies and to prescribe a product to patients with acceptable sensory qualities, it is essential to perform a precise and complete sensory characterization of these ODTs. Temporal dominance of sensations (TDS) and temporal check-allthat- apply (TCATA) methods…

Tastemedicine.medical_specialtyHealth (social science)030309 nutrition & dieteticsmedia_common.quotation_subjectSensory systemPlant ScienceAudiologylcsh:Chemical technologyHealth Professions (miscellaneous)MicrobiologySweeteningArticle03 medical and health sciences0404 agricultural biotechnologyorodispersible nutritional supplements (ODTs)Perception[SDV.IDA]Life Sciences [q-bio]/Food engineeringSensationmedicinelcsh:TP1-1185Aftertastedynamic perceptionAromamedia_common2. Zero hungertemporal check-all-that-apply (TCATA)0303 health sciencesbiologyfood and beverages04 agricultural and veterinary sciencesbiology.organism_classification040401 food scienceflavoring impactDominance (ethology)temporal dominance of sensations (TDS)Psychology[SDV.AEN]Life Sciences [q-bio]/Food and NutritionFood ScienceFoods
researchProduct

Evaluation of the validity of temporal sensory evaluation methods carried out by consumers on controlled stimuli delivered by a gustometer

2023

Temporal sensory evaluation is increasingly used with consumers. However, very few studies have investigated the repeatability and resolution of the methods used. Thus, this study aimed to fill in the gap by comparing the conclusions drawn from data collected using three temporal sensory methods performed with consumers on time model solutions delivered using a gustometer. One hundred and fifty consumers were recruited. After familiarization and a recognition task, they were divided into 3 panels, each using a different method to describe their temporal perception: Temporal Dominance of Sensations (TDS), Temporal Check-All-That-Apply (TCATA), and Attack-Evolution-Finish (AEF). Fourteen solu…

gustometer[SDV.AEN] Life Sciences [q-bio]/Food and NutritionTCATAAEFDTS
researchProduct

New Forceps and Spatula for Easy Retropupillary Implantation of Iris Claw Lenses in Aphakia: Experience in 4 Years of Use

2008

PURPOSE. Retropupillary implantation of an iris claw lens offers a rapid and atraumatic approach for rehabilitation of aphakic eyes. The difficulty in the implantation process arises because of the possibility of losing the intraocular lens (IOL) into the vitreous cavity and the need to change the hand holding the forceps during the enclavation. M ETHODS. The new forceps design radically changes the method of grasping an IOL. It contains an extendable supporting plate with a hook-like end. The instrument achieves a horizontal three-point fixation at the edge of the implant in the 6 and 12 o’clock position in order to prevent slippage into the vitreous cavity during the inclination. The supp…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentForcepsIrisIntraocular lensAphakia PostcataractAphakiaVitreous cavitylaw.inventionFixation (surgical)Lens Implantation IntraocularlawOphthalmologymedicineHumansIris clawLenses IntraocularPhacoemulsificationbusiness.industryEquipment DesignGeneral Medicinemedicine.diseaseCentrationeye diseasesSurgeryLens (optics)Ophthalmologysense organsbusinessEuropean Journal of Ophthalmology
researchProduct