Search results for "TEMPERATURE"

showing 10 items of 3798 documents

Applications of a remote sensing-based two-source energy balance algorithm for mapping surface fluxes without in situ air temperature observations

2012

Abstract The two-source energy balance (TSEB) model uses remotely sensed maps of land–surface temperature (LST) along with local air temperature estimates at a nominal blending height to model heat and water fluxes across a landscape, partitioned between dual sources of canopy and soil. For operational implementation of TSEB, however, it is often difficult to obtain representative air temperature data that are compatible with the LST retrievals, which may themselves have residual errors due to atmospheric and emissivity corrections. To address this issue, two different strategies in applying the TSEB model without requiring local air temperature data were tested over a typical Mediterranean…

Actual evapotranspirationSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaMultispectral imageEnergy balanceSoil ScienceGeologySensible heatResidualTemperature gradientBoundary layerHeat fluxEmissivityTwo-source energy balanceEnvironmental scienceComputers in Earth SciencesMediterranean climateThermal remote sensingTwo-source energy balance Actual evapotranspiration Mediterranean climate Thermal remote sensingRemote sensing
researchProduct

Acute effects of cold pack on mechanical properties of the quadriceps muscle in healthy subjects.

2012

Purpose: To examine the effects of local cooling on mechanical properties of the quadriceps muscle in healthy subjects. Subjects: Thirty-nine healthy subjects (27 women, 12 men, mean age 39, range 20e62) volunteered. Methods: A cold gel pack was applied to the quadriceps muscle for 20 min. Properties were quantified by analyzing the frequency (tension), decrement (elasticity) and stiffness of damped oscillations and the compliance of the muscle before, immediately after and after 15-min after cooling. Results: The largest responses immediately after cooling were seen in the oscillation decrement parameter, 7.9 (3.7e12.1) %, and in the compliance parameter, � 7.5 (� 9.8 to � 5.3) %. Response…

Acute effectsAdultMalemedicine.medical_specialtyTime FactorsMovementPhysical Therapy Sports Therapy and RehabilitationQuadriceps MuscleYoung AdultSkeletal pathologyInternal medicineConfidence IntervalsMedicineHumansOrthopedics and Sports MedicineMuscle SkeletalDamped oscillationsbusiness.industryQuadriceps muscleHealthy subjectsMean ageta3141General MedicineMiddle AgedConfidence intervalElasticitySurgeryBiomechanical PhenomenaMuscle RigidityCold TemperatureCryotherapyAcute DiseaseCardiologyFemalebusinessRecovery phasePhysical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine
researchProduct

Response of membrane-bound ATPase of Micrococcus luteus to heat and ultraviolet light.

1976

It is shown that the properties of ATPase (EC 3.6.1.3) of Micrococcus luteus depend only to some extent on the state of the membrane to which it is attached. Its interaction with the membrane appears to be largely controlled by polar forces. It is shown, however, that the UV-sensitivity of the membrane-bound ATPase is also significantly influenced by the state of membrane lipids.

Adenosine TriphosphatasesRadiationHot TemperatureMembranesbiologyChemistryMembrane boundUltraviolet RaysMembrane lipidsATPaseBiophysicsMicrococcusDose-Response Relationship RadiationPhospholipasebiology.organism_classificationMicrococcusRadiation EffectsMembraneBiochemistryPhospholipasesUltraviolet lightbiology.proteinMicrococcus luteusGeneral Environmental ScienceRadiation and environmental biophysics
researchProduct

Sorption Kinetics of Xenon on MFI-Type Zeolite Molecular Sieves

1990

Kinetic uptake data for xenon adsorbed onto large and uniform silicalite-I crystals are presented over a temperature range of 121 K to 296 K. — Adsorption isotherms and corrected diffusion coefficients derived from the uptake curves are given. The heat of adsorption and activation energy of diffusion were estimated from the plots of reciprocal temperature against the logarithm of equilibrium pressure and corrected diffusion coefficients, respectively. — While the corrected diffusion coefficient is independent of coverage for the higher temperatures, it decreases significantly at the lower temperatures investigated (<170 K) when the limiting adsorption capacity has been reached. — Comparing …

AdsorptionXenonChemistryGeneral Chemical EngineeringDiffusionPhysical chemistryNoble gaschemistry.chemical_elementThermodynamicsSorptionActivation energyAtmospheric temperature rangeOrder of magnitudeBerichte der Bunsengesellschaft für physikalische Chemie
researchProduct

Microvascular skin blood flow following the ingestion of 75 g glucose in healthy individuals.

2009

It is expected that microvascular blood flow might be affected by blood glucose, blood insulin and C-peptide levels. In our investigation skin microvascular blood flow (LDF) was measured using laser doppler fluxometry at skin temperatures of 37 degrees C and 44 degrees C during a 75 g oral glucose load (OGT) or water in ten healthy volunteers (6 male, 4 female, age: 28.1+/-4.0) who had fasted overnight. The transcutaneous oxygen tension (tcPO2) was measured using a transcutaneous oxygen electrode at a temperature of 44 degrees C. The microvascular response to acetylcholine was investigated before the start of the ingestion period and after 30 minutes. In addition, the capillary blood cell v…

AdultBlood GlucoseMalemedicine.medical_specialtyEndocrinology Diabetes and Metabolismmedicine.medical_treatmentBlood sugarHemodynamicschemistry.chemical_compoundEndocrinologyInternal medicineDiabetes mellitusInternal MedicinemedicineLaser-Doppler FlowmetryHumansInsulinTCPOSkinGlucose tolerance testmedicine.diagnostic_testC-Peptidebusiness.industryInsulinMicrocirculationGeneral MedicineBlood flowmedicine.diseaseAcetylcholineOxygenEndocrinologyPostprandialGlucosechemistryFemalebusinessSkin TemperatureBlood Flow VelocityExperimental and clinical endocrinologydiabetes : official journal, German Society of Endocrinology [and] German Diabetes Association
researchProduct

[Cardiovascular response to sympathetic stimulation in normal subjects with or without familial hypertension].

1990

The aim of our study was to seek out a possible different reactiveness to cardiovascular stimulation tests among normotensives with and without positive family history of essential hypertension. We have studied about 200 inhabitants of Ustica and 49 medicine students, all normotensives according to the World Health Organization and the Joint National Committee criteria. In an isolated room and in a supine position, blood pressure (BP) and heart rate were measured every 30 s for 15 min with an automatic sphygmomanometer. Averages of last 4 measurements were considered baseline values. Then we have carried out mental stress (MS), handgrip and active orthostatism test (AO) in the inhabitants o…

AdultCardiovascular Physiological PhenomenaCold TemperatureSettore MED/09 - Medicina InternaSympathetic Nervous SystemHypertensionPostureHumansMiddle AgedAdult Cardiovascular Physiological Phenomena* Cold Temperature Exercise Humans Hypertension/genetics* Middle Aged Posture Stress Psychological Sympathetic Nervous System/physiology*Settore MED/11 - Malattie Dell'Apparato CardiovascolareExerciseStress PsychologicalCardiologia (Rome, Italy)
researchProduct

Mechanical–biological waste treatment and the associated occupational hygiene in Finland

2004

A special feature of waste management in Finland has been the emphasis on the source separation of kitchen biowaste (catering waste); more than two-thirds of the Finnish population participates in this separation. Source-separated biowaste is usually treated by composting. The biowaste of about 5% of the population is handled by mechanical-biological treatment. A waste treatment plant at Mustasaari is the only plant in Finland using digestion for kitchen biowaste. For the protection of their employees, the plant owners commissioned a study on environmental factors and occupational hygiene in the plant area. During 1998-2000 the concentrations of dust, microbes and endotoxins and noise level…

AdultEngineeringbusiness.product_categoryThreshold limit valuePopulationAir MicrobiologyAir Pollutants OccupationalOccupational safety and healthWaste ManagementOccupational hygieneOccupational ExposureBiological wasteHumansRespiratoreducationWaste Management and DisposalFinlandOccupational Healtheducation.field_of_studyWaste managementbusiness.industryDry coughTemperatureDustHumidityEndotoxinsWaste treatmentNoise OccupationalbusinessWaste Management
researchProduct

Humidity of Anaesthetic Gases with Respect to Low Flow Anaesthesia

1994

It has been demonstrated in an experimental study in swine using the scanning electron microscope that a rebreathing technique utilising minimal fresh gas flowrates significantly improves climatization of anaesthetic gases. Consequently, effects of various anaesthetic techniques on airway climate must be assessed, which covers the need for suitable measuring devices. Basic principles and methods of humidity measurement in flowing anaesthetic gases include gravimetric hygrometry, dew point hygrometry, wet-dry bulb psychrometry, mass spectrometry, spectroscopic hygrometry and electrical hygrometry. A custom-made apparatus for continuous measurement of humidity and temperature in the inspired…

AdultHot TemperatureTime FactorsSwineThermometersPartial PressureAnalytical chemistryBronchiCritical Care and Intensive Care MedicineAbsorption03 medical and health sciences0302 clinical medicineAnesthesia Closed-CircuitTidal VolumeAnimalsHumansMedicineCiliaDesiccation030223 otorhinolaryngologyMoistureHygrometerbusiness.industryElectric ConductivityWaterHumidityHumidity030208 emergency & critical care medicineEquipment DesignPartial pressureRespiration ArtificialFresh gas flowVolumetric flow rateTracheaMucusAnesthesiology and Pain MedicineDew pointAnesthesiaAnesthetics InhalationGravimetric analysisVolatilizationPulmonary VentilationbusinessAnaesthesia and Intensive Care
researchProduct

Evidence that the interaction between circulating IgA and fibronectin is a normal process enhanced in primary IgA nephropathy

1991

A solid-phase ELISA was set up to measure the direct binding capacity (BC) of different, commercially available, purified human IgA preparations to plates coated with human fibronectin (FN). It was found that secretory, polymeric, and, to a much lesser extent, monomeric IgA exhibited elevated FN-BC as compared to their BC to plates coated with bovine serum albumin. This binding was specific since not observed with human IgG or IgM antibodies. In addition, we noted that this interaction was dose dependent, Ca2+ dependent, saturable, and not covalent, was inhibited by soluble FN, but not by a prior incubation of FN-coated plates with anti-human fibronectin antibodies, and appeared to involve …

AdultLiver CirrhosisMaleImmunoglobulin Amedicine.medical_specialtyHot TemperatureAdolescentImmunologyEnzyme-Linked Immunosorbent AssayAntigen-Antibody ComplexPathogenesisAntibody SpecificityInternal medicinemedicineHumansImmunology and AllergyBovine serum albuminEdetic AcidDose-Response Relationship DrugbiologyChemistryGlomerulonephritis IGAGlomerulonephritisMiddle Agedmedicine.diseaseFibronectinsFibronectinsImmunoglobulin AFibronectinDose–response relationshipEndocrinologyChromatography Gelbiology.proteinCalciumFemaleAntibody
researchProduct

Validation of ThermoHuman automatic thermographic software for assessing foot temperature before and after running

2020

The aim of the study was to evaluate an automatic thermographic software package (ThermoHuman®) for assessing skin temperature on the soles of the feet before and after running and to compare it with two manual definitions of the regions of interest (ROIs). 120 thermal images of the soles of the feet of 30 participants, at two measurement points (before and after running 30 min) and on two measurement days were analyzed. Three different models of thermographic image analyses were used to obtain the mean temperature of 9 ROIs: A) ThermoHuman (automatic definition of ROIs using ThermoHuman® software), B) Manual (manual delimitation of ROIs by proportion criteria), and C) Manual-TH (manual del…

AdultMale0106 biological sciencesPhysiologyComputer scienceSoftware Validation030310 physiology010603 evolutionary biology01 natural sciencesBiochemistryRunningYoung Adult03 medical and health sciencesSoftwareImage Processing Computer-AssistedHumansReliability (statistics)0303 health sciencesFootbusiness.industrySkin temperaturePattern recognitionReplicateSoftware packageThermographyFemaleArtificial intelligenceSkin TemperatureGeneral Agricultural and Biological SciencesbusinessSoftwareDevelopmental BiologyJournal of Thermal Biology
researchProduct