Search results for "TRAP"
showing 10 items of 2144 documents
Preferential localization of Lactococcus lactis cells entrapped in a caseinate/alginate phase separated system.
2013
International audience; This study aimed to entrap bioprotective lactic acid bacteria in a sodium caseinate/sodium alginate aqueous two-phase system. Phase diagram at pH = 7 showed that sodium alginate and sodium caseinate were not miscible when their concentrations exceeded 1% (w/w) and 6% (w/w), respectively. The stability of the caseinate/alginate two-phase system was also checked at pH values of 6.0 and 5.5. Lactococcus lactis subsp. lactis LAB3 cells were added in a 4% (w/w) caseinate/1.5% (w/w) alginate two-phase system at pH = 7. Fluorescence microscopy allowed to observe that the caseinate-rich phase formed droplets dispersed in a continuous alginate-rich phase. The distribution of …
Thermostimulated processes in statically and dynamically disordered luminescent solids
1993
Abstract Trap spectra depending on the concentration of defects in crystalline KBr-T1, LiF-Mg, Ti, A1 2 O 3 and glassy Na 2 O·SiO 2 are investigated. The nature of inhomogeneous broadening and continuous distribution of traps over activation energies at sufficiently high defect concentrations is considered. Impurity hopping controlled recombination of electronic excitations is observed. The presence of enlarged values of process activation energies and frequency factors is discussed in terms of the concept of dynamic disorder, taking into account the fluctuational changes in both the perfectpart and the structure of defects in the solid at high temperatures.
Finite-size scaling of charge carrier mobility in disordered organic semiconductors
2016
Simulations of charge transport in amorphous semiconductors are often performed in microscopically sized systems. As a result, charge carrier mobilities become system-size dependent. We propose a simple method for extrapolating a macroscopic, nondispersive mobility from the system-size dependence of a microscopic one. The method is validated against a temperature-based extrapolation [A. Lukyanov and D. Andrienko, Phys. Rev. B 82, 193202 (2010)]. In addition, we provide an analytic estimate of system sizes required to perform nondispersive charge transport simulations in systems with finite charge carrier density, derived from a truncated Gaussian distribution. This estimate is not limited t…
Plasmonic modes in molybdenum ultra-thin films suitable for hydrogenated amorphous silicon thin film solar cells
2014
We have recently demonstrated that molybdenum ultra-thin films interposed between hydrogenated amorphous silicon (a-Si:H) and SnO2:F transparent conductive oxide (TCO) in thin film solar cells show light trapping effects which enhance the solar cells performances. The effect of this improvement may be attributed to surface plasmon polariton (SPP) modes excited at the molybdenum interface by the solar radiation. In this paper we show direct evidence of such SPP modes in the case of the molybdenum/air interface by using the attenuated total reflection (ATR) technique, pioneered by Kretschmann, and we evaluate the dielectric constant of molybdenum at 660 nm. (C) 2013 The Authors. Published by …
Three-dimensional photonic crystal intermediate reflectors for enhanced light-trapping in tandem solar cells
2011
A three-dimensional photonic crystal intermediate reflector for enhanced light trapping in tandem solar cells is presented. The intermediate reflector consists of a transparent and conductive ZnO:Al inverted opal sandwiched in between the top amorphous silicon and bottom microcrystalline silicon cell.
Analytical capabilities of high performance liquid chromatography – Atmospheric pressure photoionization – Orbitrap mass spectrometry (HPLC-APPI-Orbi…
2015
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, …
Development of a Rapid Method for the Determination of Phenolic Antioxidants in Dark Chocolate Using Ultra Performance Liquid Chromatography Coupled …
2017
Development of a new comprehensive method based on one-step liquid-liquid extraction (LLE) combined with ultra-high-performance liquid chromatography-Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-HRMS) for the determination of eight phenolic compounds in dark chocolate is demonstrated. The study focuses on the optimization of sample preparation, chromatographic separation and Orbitrap-HRMS detection parameters to adjust selectivity and sensitivity of the method. The LLE mixture of formic acid-water-acetonitrile (2:58:40, v/v) and hexane at the component ratio of 1:1 (v/v) was applied for sample preparation. The inter-day and intra-day precision expressed from the relative stand…
Application of ultra-high pressure liquid chromatography linear ion-trap orbitrap to qualitative and quantitative assessment of pesticide residues
2014
Abstract The analysis of pesticides residues using a last generation high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS) was explored. Pesticides were extracted from fruits, fish, bees and sediments by QuEChERS and from water by solid-phase with Oasis HLB cartridges. Ultra-high pressure liquid chromatography (UHPLC)–LTQ-Orbitrap mass spectrometer acquired full scan MS data for quantification, and data dependent (dd) MS 2 and MS 3 product ion spectra for identification and/or confirmation. The regression coefficients ( r 2 ) for the calibration curves (two order of magnitude up to the lowest calibration level) in the study were ≥0.99. Th…
Target analysis and retrospective screening of mycotoxins and pharmacologically active substances in milk using an ultra-high-performance liquid chro…
2020
Milk is a nutritious food suitable for infants and adults, and it plays an important role in the human diet. However, it may also be a vehicle for food contaminants. In this report, we developed a method using ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-Q-Exactive Orbitrap HRMS; Thermo Fisher Scientific, Waltham, MA) for simultaneous identification of target pharmacologically active substances and mycotoxins in milk. We also used the Q-Orbitrap operating in full scan mode to identify other possible drugs and microbial metabolites that occurred in samples. Fifty-six commercially available milk samples from the Italian market were analyze…
Wide-range screening of banned veterinary drugs in urine by ultra high liquid chromatography coupled to high-resolution mass spectrometry
2012
In this work, an ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology is proposed for the multi-class multi-residue screening of banned and unauthorized veterinary drugs in bovine urine, using an Orbitrap Exactive™ analyzer working at a resolving power of 50,000 FWHM in full scan, both in positive and negative mode. The method currently covers 87 analytes belonging to different families such as steroid hormones, β-agonists, resorcylic acid lactones (RAL), stilbens, tranquillizers, nitroimidazoles, corticosteroids, NSAIDs, amphenicoles, thyreostatics and other substances such as dapsone. A database including the elemental composition, the po…